Literature DB >> 31149650

Oxygen consumption in human, tissue-engineered myobundles during basal and electrical stimulation conditions.

Brittany N Davis1, Ringo Yen1, Varun Prasad1, George A Truskey1.   

Abstract

During three-dimensional culture of skeletal muscle in vitro, electrical stimulation provides an important cue to enhance skeletal muscle mimicry of the in vivo structure and function. However, increased respiration can cause oxygen transport limitations in these avascular three-dimensional constructs, leading to a hypoxic, necrotic core, or nonuniform cell distributions in larger constructs. To enhance oxygen transport with convection, oxygen concentrations were measured using an optical sensor at the inlet and outlet of an 80 μl fluid volume microphysiological system (MPS) flow chamber containing three-dimensional human skeletal muscle myobundles. Finite element model simulations of convection around myobundles and oxygen metabolism by the myobundles in the 80 μl MPS flow chamber agreed well with the oxygen consumption rate (OCR) at different flow rates, suggesting that under basal conditions, mass transfer limitations were negligible for flow rates above 1.5 μl s-1. To accommodate electrodes for electrical stimulation, a modified 450 μl chamber was constructed. Electrical stimulation for 30 min increased the measured rate of oxygen consumption by the myobundles to slightly over 2 times the basal OCR. Model simulations indicate that mass transfer limitations were significant during electrical stimulation and, in the absence of mass transfer limitations, electrical stimulation induced about a 20-fold increase in the maximum rate of oxygen consumption. The results indicate that simulated exercise conditions increase respiration of skeletal muscle and mass transfer limitations reduce the measured levels of oxygen uptake, which may affect previous studies that model exercise with engineered muscle.

Entities:  

Year:  2019        PMID: 31149650      PMCID: PMC6520098          DOI: 10.1063/1.5093417

Source DB:  PubMed          Journal:  APL Bioeng        ISSN: 2473-2877


  8 in total

1.  A model of anemic tissue perfusion after blood transfusion shows critical role of endothelial response to shear stress stimuli.

Authors:  Weiyu Li; Amy G Tsai; Marcos Intaglietta; Daniel M Tartakovsky
Journal:  J Appl Physiol (1985)       Date:  2021-10-14

Review 2.  Microphysiological systems: What it takes for community adoption.

Authors:  Passley Hargrove-Grimes; Lucie A Low; Danilo A Tagle
Journal:  Exp Biol Med (Maywood)       Date:  2021-04-25

Review 3.  Cored in the act: the use of models to understand core myopathies.

Authors:  Aurora Fusto; Louise A Moyle; Penney M Gilbert; Elena Pegoraro
Journal:  Dis Model Mech       Date:  2019-12-19       Impact factor: 5.758

4.  Modeling statin myopathy in a human skeletal muscle microphysiological system.

Authors:  Anandita Ananthakumar; Yiling Liu; Cristina E Fernandez; George A Truskey; Deepak Voora
Journal:  PLoS One       Date:  2020-11-25       Impact factor: 3.240

Review 5.  Human Organ-on-a-Chip Microphysiological Systems to Model Musculoskeletal Pathologies and Accelerate Therapeutic Discovery.

Authors:  Raquel E Ajalik; Rahul G Alenchery; John S Cognetti; Victor Z Zhang; James L McGrath; Benjamin L Miller; Hani A Awad
Journal:  Front Bioeng Biotechnol       Date:  2022-03-14

Review 6.  Building Biomimetic Potency Tests for Islet Transplantation.

Authors:  Aaron L Glieberman; Benjamin D Pope; Douglas A Melton; Kevin Kit Parker
Journal:  Diabetes       Date:  2021-02       Impact factor: 9.461

Review 7.  Replace and repair: Biomimetic bioprinting for effective muscle engineering.

Authors:  Cooper Blake; Oliver Massey; Mitchell Boyd-Moss; Kate Firipis; Aaqil Rifai; Stephanie Franks; Anita Quigley; Robert Kapsa; David R Nisbet; Richard J Williams
Journal:  APL Bioeng       Date:  2021-07-08

8.  Microphysiological systems.

Authors:  James J Hickman; Dongeun Huh; Roger D Kamm
Journal:  APL Bioeng       Date:  2019-10-29
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.