Literature DB >> 31148272

Mechanisms, pathophysiology, and diagnostic imaging of left ventricular outflow tract obstruction following mitral valve surgery and transcatheter mitral valve replacement.

Jeffrey J Silbiger1, Samantha Lee1, Panagiota Christia1, Gila Perk1.   

Abstract

Left ventricular outflow tract obstruction is a serious complication of mitral valve surgery (repair and replacement) and transcatheter mitral valve replacement. An appreciation of the various mechanisms which cause outflow obstruction in these settings is critical to avoiding this complication and to initiating appropriate treatment. This article discusses the mechanisms, pathophysiology, and imaging of left ventricular outflow tract obstruction which can arise following insertion of a variety of mitral valve prosthetics.
© 2019 Wiley Periodicals, Inc.

Entities:  

Keywords:  chordal preservation; left ventricular outflow tract obstruction; mitral valve repair; mitral valve replacement; pannus; subaortic membrane; transcatheter mitral valve replacement

Mesh:

Year:  2019        PMID: 31148272     DOI: 10.1111/echo.14370

Source DB:  PubMed          Journal:  Echocardiography        ISSN: 0742-2822            Impact factor:   1.724


  2 in total

1.  3-dimensional printing for the diagnosis of left ventricular outflow tract obstruction after mitral valve replacement.

Authors:  Ralf Sodian; Michael Kruttschnitt; Niklas Hitschrich; Bernhard Mumm; Christian Schnell; Christian Hagl; Nikolaus Thierfelder; Fabian König
Journal:  Interact Cardiovasc Thorac Surg       Date:  2021-05-10

2.  Bioprosthetic interstrut distance subtending the preserved anterior mitral leaflet mitigates left ventricular outflow tract obstruction.

Authors:  Laurencie Brunel; Zoe A Williams; Niek J Beijerink; Benjamin M Robinson; Innes K Wise; Hugh S Paterson; Paul G Bannon
Journal:  JTCVS Open       Date:  2021-05-21
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.