Literature DB >> 31147306

Primary intra-aortic balloon support versus inotropes for decompensated heart failure and low output: a randomised trial.

Corstiaan A den Uil1, Nicolas M Van Mieghem, Marcelo B Bastos, Lucia S Jewbali, Mattie J Lenzen, Annemarie E Engstrom, Jeroen J H Bunge, Jasper J Brugts, Olivier C Manintveld, Joost Daemen, Jeroen M Wilschut, Felix Zijlstra, Alina A Constantinescu.   

Abstract

AIMS: The haemodynamic effects of primary implantation of an intra-aortic balloon pump (IABP) versus inotropes in decompensated heart failure and low output (DHF-LO), but without an acute coronary syndrome, have not been investigated. We therefore aimed to investigate the effect of primary IABP implantation as compared to inotropes on haemodynamics in DHF-LO with no acute ischaemia. METHODS AND
RESULTS: Patients (n=32) with DHF-LO despite IV diuretics were randomised to primary 50 mL IABP or inotropes (INO: enoximone or dobutamine). The primary endpoint was the improvement of organ perfusion assessed by ∆ mixed-venous oxygen saturation (SvO2) at 3 hours; secondary endpoints included ∆ cardiac power output (CPO), NT-proBNP proportional change, cumulative fluid balance and ∆ dyspnoea severity score, all at 48 hours. Data are presented as median (IQR). Patients were 60 (48-69) years old and 72% were male. Baseline SvO2 was 44 (39-53)%. ∆SvO2 was higher in the IABP group (+17 [+9; +24] vs. +5 [+2; +9]%, p<0.05). IABP patients had a higher ∆CPO, a greater relative reduction in NT-proBNP, a more negative cumulative fluid balance, and a greater reduction in dyspnoea severity score. There were no IABP-related serious adverse events (SAEs). Thirty-day mortality was 23% (IABP) vs. 44% (INO).
CONCLUSIONS: Primary circulatory support by IABP showed a significant increase in improved organ perfusion assessed by SvO2.

Entities:  

Mesh:

Substances:

Year:  2019        PMID: 31147306     DOI: 10.4244/EIJ-D-19-00254

Source DB:  PubMed          Journal:  EuroIntervention        ISSN: 1774-024X            Impact factor:   6.534


  6 in total

1.  Circulatory support with larger volume intra-aortic balloon pump vs. standard volume or no-balloon pump during high-risk percutaneous coronary interventions. A randomised study.

Authors:  Aleksander Zeliaś; Wojciech Zajdel; Krzysztof Malinowski; Jolanta Geremek; Krzysztof Żmudka
Journal:  Postepy Kardiol Interwencyjnej       Date:  2020-04-03       Impact factor: 1.426

2.  Predictors of In-hospital Mortality in Cardiogenic Shock Patients on Vasoactive or Inotropic Support.

Authors:  Shuktika Nandkeolyar; Tanya Doctorian; Gary Fraser; Rachel Ryu; Colleen Fearon; David Tryon; Whitney Kagabo; Dmitry Abramov; Christopher Hauschild; Liset Stoletniy; Anthony Hilliard; Antoine Sakr
Journal:  Clin Med Insights Cardiol       Date:  2021-10-27

3.  Bedside intra-aortic balloon pump insertion in cardiac intensive care unit: A single-center experience.

Authors:  Luca Baldetti; Alessandro Beneduce; Antonio Boccellino; Matteo Pagnesi; Giuseppe Barone; Guglielmo Gallone; Antonio Napolano; Mario Gramegna; Francesco Calvo; Vittorio Pazzanese; Stefania Sacchi; Alberto M Cappelletti
Journal:  Catheter Cardiovasc Interv       Date:  2022-04-14       Impact factor: 2.585

4.  Predicting survival in patients with acute decompensated heart failure complicated by cardiogenic shock.

Authors:  Nuccia Morici; Giovanna Viola; Laura Antolini; Gianfranco Alicandro; Michela Dal Martello; Alice Sacco; Maurizio Bottiroli; Federico Pappalardo; Luca Villanova; Laura De Ponti; Carlo La Vecchia; Maria Frigerio; Fabrizio Oliva; Justin Fried; Paolo Colombo; Arthur Reshad Garan
Journal:  Int J Cardiol Heart Vasc       Date:  2021-06-04

5.  Inotropic agents and vasodilator strategies for the treatment of cardiogenic shock or low cardiac output syndrome.

Authors:  Konstantin Uhlig; Ljupcho Efremov; Jörn Tongers; Stefan Frantz; Rafael Mikolajczyk; Daniel Sedding; Julia Schumann
Journal:  Cochrane Database Syst Rev       Date:  2020-11-05

Review 6.  Mechanical Support in Early Cardiogenic Shock: What Is the Role of Intra-aortic Balloon Counterpulsation?

Authors:  Jesse R Kimman; Nicolas M Van Mieghem; Henrik Endeman; Jasper J Brugts; Alina A Constantinescu; Olivier C Manintveld; Eric A Dubois; Corstiaan A den Uil
Journal:  Curr Heart Fail Rep       Date:  2020-10
  6 in total