Literature DB >> 31146930

Comparison of intraocular lens power calculation formulas in Chinese eyes with axial myopia.

Jiewei Liu1, Li Wang2, Feiyan Chai3, Yu Han3, Suqin Qian4, Douglas D Koch2, Mitchell P Weikert2.   

Abstract

PURPOSE: To assess the accuracy of intraocular lens (IOL) power calculation formulas in Chinese eyes with axial lengths (ALs) longer than 26.0 mm.
SETTING: Department of Cataract Surgery, Shanxi Eye Hospital, China.
DESIGN: Prospective case series.
METHODS: This study evaluated (1) two new formulas (Barrett Universal II and Hill-RBF 2.0), (2) three vergence formulas (Haigis, Holladay 1, and SRK/T), and (3) the original and modified Wang-Koch AL adjustment formulas with Holladay 1 and SRK/T. The User Group for Laser Interference Biometry lens constants were used for IOL power calculation. The refractive prediction error was calculated by subtracting the predicted refraction from the actual refraction postoperatively. The mean numerical error (MNE), percentage of eyes with hyperopic outcomes, and mean absolute error (MAE) were determined.
RESULTS: The study comprised 136 eyes. The Barrett and Hill-RBF formulas had MNEs close to zero (-0.09 D to 0.03 D), the Haigis, Holladay 1, and SRK/T produced hyperopic MNEs (0.25 to 0.70 D), and the original and modified Wang-Koch AL adjustment formulas induced myopic MNEs (-0.48 to -0.22 D). The original Wang-Koch formulas produced significantly lower percentages of eyes with hyperopic outcomes (15% to 18%) than all other formulas (28% to 91%). There were no significant differences in MAEs between the Barrett, Hill-RBF, Haigis, and original and modified Wang-Koch adjustment with the Holladay 1 (0.32 to 0.41 D).
CONCLUSION: The performances of the Barrett and Hill-RBF were comparable in long eyes. The incidence of hyperopic outcome with the Wang-Koch AL adjustment formula was significantly lower than other formulas.
Copyright © 2019. Published by Elsevier Inc.

Entities:  

Year:  2019        PMID: 31146930     DOI: 10.1016/j.jcrs.2019.01.018

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  11 in total

1.  Comparing the accuracy of the new-generation intraocular lens power calculation formulae in axial myopic eyes: a meta-analysis.

Authors:  Hongyu Li; Zi Ye; Yu Luo; Zhaohui Li
Journal:  Int Ophthalmol       Date:  2022-09-05       Impact factor: 2.029

2.  Predictability of combined cataract surgery and trabeculectomy using Barrett Universal Ⅱ formula.

Authors:  Kei Iijima; Kazutaka Kamiya; Yoshihiko Iida; Masayuki Kasahara; Nobuyuki Shoji
Journal:  PLoS One       Date:  2022-06-23       Impact factor: 3.752

3.  Application of total keratometry in ten intraocular lens power calculation formulas in highly myopic eyes.

Authors:  Ling Wei; Kaiwen Cheng; Wenwen He; Xiangjia Zhu; Yi Lu
Journal:  Eye Vis (Lond)       Date:  2022-06-09

4.  Comparison of accuracy of intraocular lens power calculation for eyes with an axial length greater than 29.0 mm.

Authors:  Chengyao Guo; Shengjie Yin; Kunliang Qiu; Mingzhi Zhang
Journal:  Int Ophthalmol       Date:  2022-05-10       Impact factor: 2.029

5.  Accuracy of intraocular lens calculation formulas for eyes with insufficient capsular support.

Authors:  Zhouyue Li; Zhangkai Lian; Charlotte Aimee Young; Jing Zhao; Guangming Jin; Danying Zheng
Journal:  Ann Transl Med       Date:  2021-02

6.  Associations between anterior segment biometry and high axial myopia in 3438 cataractous eyes in the Chinese population.

Authors:  Ao Miao; Yating Tang; Xiangjia Zhu; Dongjin Qian; Tianyu Zheng; Yi Lu
Journal:  BMC Ophthalmol       Date:  2022-02-12       Impact factor: 2.209

7.  Predictability of 6 Intraocular Lens Power Calculation Formulas in People With Very High Myopia.

Authors:  Yi-Ching Chu; Tzu-Lun Huang; Pei-Yao Chang; Wei-Ting Ho; Yung-Ray Hsu; Shu-Wen Chang; Jia-Kang Wang
Journal:  Front Med (Lausanne)       Date:  2022-04-08

8.  Investigating the Prediction Accuracy of Recently Updated Intraocular Lens Power Formulas with Artificial Intelligence for High Myopia.

Authors:  Miki Omoto; Kaoruko Sugawara; Hidemasa Torii; Erisa Yotsukura; Sachiko Masui; Yuta Shigeno; Yasuyo Nishi; Kazuno Negishi
Journal:  J Clin Med       Date:  2022-08-18       Impact factor: 4.964

Review 9.  Update on Intraocular Lens Formulas and Calculations.

Authors:  Tina Xia; Christine E Martinez; Linda M Tsai
Journal:  Asia Pac J Ophthalmol (Phila)       Date:  2020 May-Jun

10.  Accuracy of the Barrett Universal II formula integrated into a commercially available optical biometer when using a preloaded single-piece intraocular lens.

Authors:  Hiroki Mieno; Osamu Hieda; Toshihide Ikeda; Shino Hayashi; Masatsugu Hashida; Kimiaki Urabe; Chie Sotozono
Journal:  Indian J Ophthalmol       Date:  2021-09       Impact factor: 1.848

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.