Literature DB >> 3114676

Increased free-radical activity during haemodialysis?

E R Maher, D G Wickens, J F Griffin, P Kyle, J R Curtis, T L Dormandy.   

Abstract

Free-radical activity was studied in patients on maintenance haemodialysis by measuring plasma octadeca-9, 11-dienoic acid (9,11-LA'), a diene-conjugated derivative of linoleic acid. Baseline values of 9,11-LA' (esterified as phospholipids and as free fatty acids) in 51 haemodialysis patients were similar to that of normal control subjects. However, during haemodialysis there was a highly significant (P less than 0.001) increase in 9,11-LA' in all 13 patients studied, which reached a peak 30 min after haemodialysis was started and then declined. The rise in plasma 9,11-LA' may be due to free radicals generated by activated neutrophils. Abnormal free-radical activity may be partly responsible for some haemodialysis-related complications, including pulmonary dysfunction in early haemodialysis.

Entities:  

Mesh:

Substances:

Year:  1987        PMID: 3114676

Source DB:  PubMed          Journal:  Nephrol Dial Transplant        ISSN: 0931-0509            Impact factor:   5.992


  5 in total

1.  Assessment of erythrocyte shape by flow cytometry techniques.

Authors:  M Piagnerelli; K Zouaoui Boudjeltia; D Brohee; A Vereerstraeten; P Piro; J-L Vincent; M Vanhaeverbeek
Journal:  J Clin Pathol       Date:  2006-06-14       Impact factor: 3.411

Review 2.  Oxidative Stress in Hemodialysis Patients: A Review of the Literature.

Authors:  Vassilios Liakopoulos; Stefanos Roumeliotis; Xenia Gorny; Evangelia Dounousi; Peter R Mertens
Journal:  Oxid Med Cell Longev       Date:  2017-09-12       Impact factor: 6.543

3.  Vitamin e-loaded membrane dialyzers reduce hemodialysis inflammaging.

Authors:  Vincenzo Sepe; Marilena Gregorini; Teresa Rampino; Pasquale Esposito; Rosanna Coppo; Francesco Galli; Carmelo Libetta
Journal:  BMC Nephrol       Date:  2019-11-15       Impact factor: 2.388

Review 4.  Possible benefits of exogenous melatonin for individuals on dialysis: a narrative review on potential mechanisms and clinical implications.

Authors:  Seyed Majid Mousavi Movahhed
Journal:  Naunyn Schmiedebergs Arch Pharmacol       Date:  2021-06-07       Impact factor: 3.000

5.  Effect of reuse of polysulfone membrane on oxidative stress during hemodialysis.

Authors:  P Ramakrishna; E Prabhakar Reddy; M M Suchitra; A R Bitla; P V Srinivasa Rao; V Sivakumar
Journal:  Indian J Nephrol       Date:  2012-05
  5 in total