Literature DB >> 31145930

Mitigation of microbial contamination from waste water and aerosolization by sink design.

K Cole1, J E Talmadge2.   

Abstract

BACKGROUND: Healthcare-associated infections (HAIs) are a significant cause of increased medical costs, morbidity, mortality, and have been partly associated with sinks, their waste water outlets and associated pipework. AIM: To determine whether an engineered sink could limit microbial aerosol contaminants in the air and sink basin.
METHODS: Multiple comparisons were undertaken between an experimental sink, designed to limit aerosolization and p-trap contamination to a control hospital sink, both connected to a common drain system. The experimental sink was equipped with ultraviolet light (UV), an aerosol containment hood, ozonated water generator and a flush system to limit bacterial growth/aerosolization and limit microbial growth in the p-trap. Nutrient material was added daily to simulate typical material discarded into a hospital sink. Surface collection swabs, settle plates and p-trap contamination levels were assessed for bacteria and fungi.
FINDINGS: The experimental sink had significantly decreased levels of bacterial and fungal p-trap contamination (99.9% for Tryptic Soy (TSA) and Sabouraud agar (SAB) plates) relative to the initial levels. Aerosol-induced contaminant from the p-traps was significantly lower for the experimental vs the control sink for TSA (76%) and SAB (86%) agar settle plates.
CONCLUSIONS: Limiting microbial contamination is critical for the control of nosocomial infections of in-room sinks, which provide a major source of contamination. Our experimental sink studies document that regular ozonated water rinsing of the sink surface, decontamination of p-trap water, and UV decontamination of surfaces limits microbial aerosolization and surface contamination, with potential to decrease patient exposure and reduce hospital acquired infections.
Copyright © 2019 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Decontamination; Hospital; Infection; Ozone; Sink; Ultraviolet

Mesh:

Substances:

Year:  2019        PMID: 31145930     DOI: 10.1016/j.jhin.2019.05.011

Source DB:  PubMed          Journal:  J Hosp Infect        ISSN: 0195-6701            Impact factor:   3.926


  2 in total

1.  Role of the environment in transmission of Gram-negative bacteria in two consecutive outbreaks in a haematology-oncology department.

Authors:  W C van der Zwet; I E J Nijsen; C Jamin; L B van Alphen; C J H von Wintersdorff; A M P Demandt; P H M Savelkoul
Journal:  Infect Prev Pract       Date:  2022-02-25

2.  Antimicrobial efficacy of aqueous ozone in combination with short chain fatty acid buffers.

Authors:  Holly C Britton; Michael Draper; James E Talmadge
Journal:  Infect Prev Pract       Date:  2019-12-16