| Literature DB >> 31144201 |
Julian A Luetkens1, Sabine Klein2, Frank Träber3, Wolfgang Block3, Frederic C Schmeel3, Alois M Sprinkart3, Daniel L R Kuetting3, Frank E Uschner2, Robert Schierwagen2, Daniel Thomas3, Jonel Trebicka2,4,5,6, Guido M Kukuk3.
Abstract
BACKGROUND: To determine the utility of single-contrast-bolus hepatic extracellular volume (ECV) fraction measurement at different time points to detect and quantify hepatic fibrosis.Entities:
Keywords: Extracellular space; Fibrosis; Liver; Magnetic resonance imaging; Rats (Sprague-Dawley)
Year: 2019 PMID: 31144201 PMCID: PMC6541689 DOI: 10.1186/s41747-019-0100-y
Source DB: PubMed Journal: Eur Radiol Exp ISSN: 2509-9280
Fig. 1Exemplary measurements of hepatic T1 relaxation times. Circular regions of interest are drawn in the right lobe of the liver and in the abdominal aorta. Measurements are given for pre-contrast (A) and 15 min post-contrast images (B)
Fig. 2Change on mean extracellular volume (ECV) fraction measurements over time. Measurements are given for the control group and for the 8 and 16 weeks carbon-tetrachloride (CCl4) groups
General characteristic of different groups of CCL4 rats
| Parameter | Control ( | 8-week CCl4 ( | 16-week CCL4 ( | |
|---|---|---|---|---|
| Body weight (g) | 488.0 ± 81.1 | 368.7 ± 45.7* | 499.3 ± 54.8# | < 0.001 |
| Liver weight (g) | 15.3 ± 2.7 | 14.6 ± 2.3 | 17.2 ± 2.8 | 0.081 |
| Mean arterial pressure (mmHg) | 113.4 ± 16.4 | 103.9 ± 22.7 | 102.5 ± 21.4 | 0.287 |
| Portal pressure (mmHg) | 9.0 ± 1.3 | 15.0 ± 2.6* | 19.1 ± 7.5* | < 0.001 |
| Positive staining Sirius red (%) | 0.1 ± 0.1 | 3.3 ± 2.6* | 25.1 ± 3.2*# | < 0.001 |
| Native T1 relaxation time (ms) | 593.3 ± 10.3 | 625.5 ± 38.3 | 645.6 ± 41.0* | 0.007 |
| 5 min extracellular volume fraction (%) | 17.8 ± 2.4 | 23.5 ± 4.8 | 29.1 ± 3.5* | < 0.001 |
| 15 min extracellular volume fraction (%) | 18.0 ± 3.0 | 23.6 ± 4.8 | 30.5 ± 3.3*# | < 0.001 |
| 25 min extracellular volume fraction (%) | 18.3 ± 3.0 | 23.7 ± 4.7 | 31.2 ± 2.4*# | < 0.001 |
Data are presented as mean ± standard deviation. CCl carbon tetrachloride. * p < 0.05 versus control; # p < 0.05 versus 8-week CCl4
Fig. 3Scatter plots showing correlations between extracellular volume (ECV) fraction and positive staining for Sirius red 5 (A), 15 (B), and 25 min (C) after contrast administration