Literature DB >> 31141490

Strain and dyssynchrony in fetuses with congenital heart disease compared to normal controls using speckle tracking echocardiography (STE).

Marie-Charlotte Véronique Drop1, Mareike Möllers2, Kerstin Hammer2, Kathrin Oelmeier de Murcia2, Maria Karina Falkenberg2, Janina Braun2, Maria Eveslage3, Helen Ann Köster2, Walter Klockenbusch2, Johannes Steinhard4, Ralf Schmitz2.   

Abstract

Objective To compare myocardial strain and mechanical dyssynchrony in fetuses with congenital heart disease (CHD) to normal controls using speckle tracking echocardiography (STE). Methods In this comparative cross-sectional study 23 fetuses with CHD and 105 normal controls between 19 and 41 weeks of gestation were assessed with STE. The STE sample box was placed over the myocardium of both ventricles. The parameters of interest included the segmental strain of the left (LV-S) and right lateral ventricle wall (RV-S) and the global ventricular strain of both chambers (2C-S). In order to separately assess the LV, we placed the STE sample box over the myocardium of the LV. We calculated the strain of the LV lateral wall (LW-S), the septum (SEPT-S) and the global ventricular strain of the single LV (1C-S). Furthermore, we analyzed the differences in timing of negative peak myocardial strain between the LV and RV (two-chamber dyssynchrony, 2C-DYS) and also within the LV between the lateral wall and the septum (one-chamber dyssynchrony, 1C-DYS). Results The evaluation of strain and mechanical dyssynchrony was feasible in all cases. Compared to normal controls, fetuses with CHD showed lower segmental and global strain values and the extent of 2C-DYS and 1C-DYS was higher than in the healthy control group. Conclusion The deterioration of myocardial function in CHD can be measured with STE. The assessment of strain and dyssynchrony with STE may be useful for distinguishing fetuses with CHD from healthy fetuses.

Entities:  

Keywords:  congenital heart disease; dyssynchrony; echocardiography; prenatal diagnosis; speckle tracking echocardiography; strain

Mesh:

Year:  2019        PMID: 31141490     DOI: 10.1515/jpm-2019-0073

Source DB:  PubMed          Journal:  J Perinat Med        ISSN: 0300-5577            Impact factor:   1.901


  1 in total

1.  Evaluation of cardiac function and systolic dyssynchrony of fetuses exposed to maternal autoimmune diseases using speckle tracking echocardiography.

Authors:  ShaSha Duan; Si Ha; ShuJuan Li; YaXi Wang; YiLu Shi; HaiYue Zhao; Lu Zhang; XiaoShan Zhang; Yong Wang
Journal:  Clin Rheumatol       Date:  2021-04-04       Impact factor: 2.980

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.