Immediate And Long Term Effects Of Percutaneous Mitral Balloon Valvuloplasty On Atrial Conduction Velocities In Patients With Mitral Stenosis.

Hicaz Zencirkiran Agus1, Serkan Kahraman1, Begum Uygur1, Arda Guler1, Gokhan Demirci1, Ali Kemal Kalkan1, Mehmet Erturk1, Mustafa Yildiz1.   

Abstract

BACKGROUND: P-wave dispersion (PWD) is an electrocardiographic (ECG) marker of nonuniform and heterogeneous atrial conduction with ECG leads of different orientation. The aim of our study was to investigate the immediate and long term effects of successful percutaneous mitral balloon valvuloplasty (PMBV) on PWD in severe rheumatic MS patients and to analyse the restenosis, atrial fibrillation (AF) and redo balloon valvuloplasty rate.
METHODS: We enrolled 41 consecutive MS patients with sinus rhythm who underwent PMBV. A 12-lead ECG and transthoracic echocardiography were performed for each patient one day before, within 72 hours after the procedure and followed up by clinical visit at a mean of 5,57±1,46 (3-8) year.The mean patient age was 44.1±10.86 years.
RESULTS: Pmax 1(pre PMBV) and PWD 1(pre PMBV) decreased 1-3 days after PMBV. MVA improved immediately after the procedure; but lately the mean MVA decreased significantly indicating the initiation of restenosis. Composite endpoints were associated with LA 1 (p = 0.02), MVA 2 (1-3 days after PMBV) (p= 0.019), mean gradient 2 (p= 0.028), PWD 3 (3 years after PMBV) (p < 0.001) and Pmax 3 (3 years after PMBV) (<0,001). AF incidence was associated with PWD 2 (p=0,019) and PWD 3 (p=0,010). There was 14 composite endpoint on follow up and at multivariate analysis PWD 3 was identified as an independent predictor of the composite endpoint (p=0.048, hazard ratio=1.36, 95% confidence interval (CI): 1,002-1.867).
CONCLUSIONS: This study has demonstrated that Pmax and PWD significantly decreased within 3 days after PMBV. Furthermore, long term PWD was associated with AF and identified as an independent predictor of the composite endpoint.

Entities:  

Keywords:  P wave dispersion; Percutaneous mitral balloon valvuloplasty; mitral stenosis

Year:  2019        PMID: 31139300      PMCID: PMC6533828          DOI: 10.4022/jafib.2124

Source DB:  PubMed          Journal:  J Atr Fibrillation        ISSN: 1941-6911


  16 in total

1.  Effects of percutaneous mitral balloon valvuloplasty on P-wave dispersion in patients with mitral stenosis.

Authors:  Hasan Turhan; Ertan Yetkin; Kubilay Senen; M Birhan Yilmaz; Mehmet Ileri; Ramazan Atak; Sengul Cehreli; Emine Kutuk
Journal:  Am J Cardiol       Date:  2002-03-01       Impact factor: 2.778

2.  Late (two-year) follow-up after percutaneous balloon mitral valvotomy.

Authors:  P C Block; I F Palacios; E H Block; E M Tuzcu; B Griffin
Journal:  Am J Cardiol       Date:  1992-02-15       Impact factor: 2.778

3.  Increased P-wave dispersion predicts recurrent atrial fibrillation after cardioversion.

Authors:  Christian Perzanowski; Andrew T Ho; Alan K Jacobson
Journal:  J Electrocardiol       Date:  2005-01       Impact factor: 1.438

4.  Effects of long-term beta-blocker therapy on P-wave duration and dispersion in patients with rheumatic mitral stenosis.

Authors:  Ali Riza Erbay; Hasan Turhan; Ayse Saatci Yasar; Asuman Bicer; Kubilay Senen; Hatice Sasmaz; Irfan Sabah; Ertan Yetkin
Journal:  Int J Cardiol       Date:  2005-06-22       Impact factor: 4.164

5.  Favorable effect of balloon mitral valvuloplasty on the incidence of atrial fibrillation in patients with severe mitral stenosis.

Authors:  Mohamed Eid Fawzy; Mohamed Shoukri; Hani Al Sergani; Bahaa Fadel; Abdulmoniem Eldali; Mohammed Al Amri; Charles C Canver
Journal:  Catheter Cardiovasc Interv       Date:  2006-10       Impact factor: 2.692

6.  P wave dispersion on 12-lead electrocardiography in patients with paroxysmal atrial fibrillation.

Authors:  K Aytemir; N Ozer; E Atalar; E Sade; S Aksöyek; K Ovünç; A Oto; F Ozmen; S Kes
Journal:  Pacing Clin Electrophysiol       Date:  2000-07       Impact factor: 1.976

7.  Immediate and mid-term results of repeat percutaneous mitral commissurotomy for restenosis following earlier percutaneous mitral commissurotomy.

Authors:  B Iung; E Garbarz; P Michaud; O Fondard; S Helou; J Kamblock; P Berdah; P L Michel; P Lionet; B Cormier; G Papouin; A Vahanian
Journal:  Eur Heart J       Date:  2000-10       Impact factor: 29.983

8.  Long-term follow-up of P-wave duration and dispersion in patients with mitral stenosis.

Authors:  Unal Guntekin; Yilmaz Gunes; Mustafa Tuncer; Ahmet Gunes; Musa Sahin; Hakki Simsek
Journal:  Pacing Clin Electrophysiol       Date:  2008-12       Impact factor: 1.976

9.  The acute effect of percutaneous mitral balloon valvuloplasty on atrial electromechanical delay and P-wave dispersion in patients with mitral stenosis.

Authors:  B Demirkan; Y Guray; U Guray; M R Ege; H L Kisacik; H Sasmaz; S Korkmaz
Journal:  Herz       Date:  2012-09-08       Impact factor: 1.443

10.  Electrocardiographic P-wave Indices as a Useful Tool to Predict Successful Percutaneous Balloon Mitral Valvotomy in Patients with Mitral Stenosis.

Authors:  Babak Kazemi; Ali Rostami; Naser Aslanabadi; Samad Ghaffari
Journal:  J Cardiovasc Thorac Res       Date:  2014-03-21
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.