Abstract
Lumbar cerebrospinal fluid drainage has been widely performed in patients at the bedside; however, technical failure can occasionally occur as a result of blind maneuvering. Herein, we present the use of rotational fluoroscopic unit-guided lumbar drainage for patients with an unsuccessful initial attempt at bedside. In four of the 24 patients with aneurysmal subarachnoid hemorrhage, initial lumbar drainage could not be performed at bedside. Thus, a three-dimensional rotational technology guided by a high-quality fluoroscopic unit was used. After a cone-beam computed tomography scan was performed, an accurate puncture point and a target thecal sac were identified using the software. The fluoroscopic unit helped us to identify the puncture point and trajectory with a laser pointer on the patient. A needle was inserted along the tract until the cerebrospinal fluid was collected. The lumbar drainage tube was successfully inserted with a single puncture in all four patients. Rotational fluoroscopic technology helps to identify a suitable puncture point, trajectory and target site for lumbar spinal drainage. Our technique is considerably useful in an era wherein minimally invasive procedures are preferred.Entities:
Keywords: 3D fluoroscopic unit; lumbar drainage; minimally invasive; spinal drainage
Mesh:
Year: 2019 PMID: 31138040 PMCID: PMC6547205 DOI: 10.1177/1591019918823997
Source DB: PubMed Journal: Interv Neuroradiol ISSN: 1591-0199 Impact factor: 1.610