Literature DB >> 31131996

Intra-Abdominal Adipose Tissue Quantification by Alternative Versus Reference Methods: A Systematic Review and Meta-Analysis.

Jessica Murphy1,2,3, Simon L Bacon1,3,4, José A Morais1,5,6, Michael A Tsoukas6, Sylvia Santosa1,2,3.   

Abstract

OBJECTIVE: This meta-analysis aimed to assess the agreement between intra-abdominal adipose tissue (IAAT) quantified by alternative methods and the reference standards, computed tomography (CT) and magnetic resonance imaging (MRI).
METHODS: MEDLINE and EMBASE electronic databases were systematically searched to identify studies that quantified IAAT thickness, area, or volume by a comparator method and CT or MRI. Using an inverse variance weighted approach (random-effects model), the mean differences and 95% limits of agreement (LoA) were pooled between methods.
RESULTS: The meta-analysis included 24 studies using four comparator methods. The pooled mean differences were -0.3 cm (95% LoA: -3.4 to 3.2 cm; P = 0.400) for ultrasound and -11.6 cm2 (95% LoA: -43.1 to 19.9 cm2 ; P = 0.004) for bioelectrical impedance analysis. Dual-energy x-ray absorptiometry (DXA) quantified both IAAT area and volume with mean differences of 8.1 cm2 (95% LoA: -98.9 to 115.1 cm2 ; P = 0.061) and 10 cm3 (95% LoA: -280 to 300 cm3 ; P = 0.808), respectively.
CONCLUSIONS: Ultrasound and DXA measure IAAT with minimal bias from CT or MRI, while bioelectrical impedance analysis systematically underestimates IAAT. However, with the exception of DXA for IAAT volume, the wide LoA caution against clinical or research use of the comparator methods and emphasize the need to optimize alternatives to the reference standards.
© 2019 The Obesity Society.

Mesh:

Year:  2019        PMID: 31131996     DOI: 10.1002/oby.22494

Source DB:  PubMed          Journal:  Obesity (Silver Spring)        ISSN: 1930-7381            Impact factor:   5.002


  3 in total

1.  Half-body MRI volumetry of abdominal adipose tissue in patients with obesity.

Authors:  Nicolas Linder; Kilian Solty; Anna Hartmann; Tobias Eggebrecht; Matthias Blüher; Roland Stange; Harald Busse
Journal:  BMC Med Imaging       Date:  2019-10-22       Impact factor: 1.930

2.  Android to gynoid fat ratio and its association with functional capacity in male patients with heart failure.

Authors:  Marcelo Rodrigues Dos Santos; Guilherme Wesley Peixoto da Fonseca; Letícia Pironato Sherveninas; Francis Ribeiro de Souza; Antônio Carlos Battaglia Filho; Caio Eduardo Novaes; Rosa Maria Rodrigues Pereira; Carlos Eduardo Negrão; Antônio Carlos Pereira Barretto; Maria-Janieire de Nazaré Nunes Alves
Journal:  ESC Heart Fail       Date:  2020-03-27

3.  Body height and waist circumference of young Swiss men as assessed by 3D laser-based photonic scans and by manual anthropometric measurements.

Authors:  Kaspar Staub; Nicole Bender; Claudia Beckmann; Lafi Aldakak; Patrick Eppenberger; Frank Rühli
Journal:  PeerJ       Date:  2019-12-12       Impact factor: 2.984

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.