Yang Li1, Yan Sha1, Feng Wang2, Ping Lu3, Xilan Liu1, Yaru Sheng1, Zhongshuai Zhang4, Mengxiao Liu4. 1. a Department of Radiology , Eye & ENT Hospital of Fudan University , Shanghai , China. 2. b Department of Ultrasound , Weifang People's Hospital , Weifang , China. 3. c Department of Radiology , Suzhou Municipal Hospital , Suzhou , China. 4. d Siemens Healthcare Ltd. , Shanghai , China.
Abstract
Background: Intratympanic and intravenous gadolinium administration is used to visualise endolymphatic hydrops. Aims/objectives: The goal of this study was to compare the image quality between intratympanic (IT-method) and intravenous (IV-method) gadolinium administration using three-dimensional inversion recovery with real reconstruction (3D real IR) sequences. Materials and methods: A number of 152 patients with Meniere's disease were included. The 3D real IR sequence was performed 24 h after IT administration or 4 h after IV administration. The detection rate of endolymphatic hydrops, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) of the two methods were compared. Specifically, the average image scores of the two methods were evaluated by two radiologists. Results: The SNRROI and CNRs of the IT-method were higher than those of the IV-method, whereas no significant difference between the IT-method and IV-method with regard to the SNRB was found. The average image scores were 3.49 ± 0.12 and 3.30 ± 0.12 for the IT-method and IV-method, respectively (p = .229). No statistically significant difference was found between two methods in terms of the detection rate of endolymphatic hydrops. Conclusions and significance: IT-method images can display endolymphatic hydrops more precisely than IV-method images. The IV-method can be used as an alternative to the IT-method in clinical applications to some extent.
Background: Intratympanic and intravenous gadolinium administration is used to visualise endolymphatic hydrops. Aims/objectives: The goal of this study was to compare the image quality between intratympanic (IT-method) and intravenous (IV-method) gadolinium administration using three-dimensional inversion recovery with real reconstruction (3D real IR) sequences. Materials and methods: A number of 152 patients with Meniere's disease were included. The 3D real IR sequence was performed 24 h after IT administration or 4 h after IV administration. The detection rate of endolymphatic hydrops, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) of the two methods were compared. Specifically, the average image scores of the two methods were evaluated by two radiologists. Results: The SNRROI and CNRs of the IT-method were higher than those of the IV-method, whereas no significant difference between the IT-method and IV-method with regard to the SNRB was found. The average image scores were 3.49 ± 0.12 and 3.30 ± 0.12 for the IT-method and IV-method, respectively (p = .229). No statistically significant difference was found between two methods in terms of the detection rate of endolymphatic hydrops. Conclusions and significance: IT-method images can display endolymphatic hydrops more precisely than IV-method images. The IV-method can be used as an alternative to the IT-method in clinical applications to some extent.
Entities:
Keywords:
3D real IR ; Endolymphatic hydrops; intratympanic gadolinium administration; intravenous gadolinium administration
Authors: S Nahmani; A Vaussy; C Hautefort; J-P Guichard; A Guillonet; E Houdart; A Attyé; M Eliezer Journal: AJNR Am J Neuroradiol Date: 2020-03-19 Impact factor: 3.825