Literature DB >> 31124827

Influence of Implant Length and Associated Parameters Upon Biomechanical Forces in Finite Element Analyses: A Systematic Review.

Lukas Hingsammer1, Bernhard Pommer2, Stefan Hunger3, Rapahel Stehrer4, Georg Watzek5, Angel Insua6.   

Abstract

PURPOSE: The aim of this systematic review is to provide an overview of finite element analyses comparing standard and short dental implants concerning biomechanical properties and to detect the most relevant parameters affecting periimplant stress concentrations.
MATERIAL AND METHODS: After screening the literature and assessment of studies, 36 studies were included in this review.
RESULTS: Eighty-three percent of the studies state that short dental implants have to bear higher stress concentrations compared with standard length implants. At the same time, 44% of articles note that implant diameter can be considered a more effective design parameter than implant length to reduce stress concentrations and to avoid an overload of periimplant bone. Regardless of implant dimension, in all studies, the highest stress concentrations are found in the cortical section around the upper part of the implant.
CONCLUSIONS: Unaffected of bone quality, implant diameter is found to play a key role to minimize periimplant stress concentrations. Concerning stress reduction implant length gains increasing relevance with decreasing bone density. Furthermore, splinting of short implants constitute an appropriate tool to avoid crestal overloading.

Mesh:

Substances:

Year:  2019        PMID: 31124827     DOI: 10.1097/ID.0000000000000879

Source DB:  PubMed          Journal:  Implant Dent        ISSN: 1056-6163            Impact factor:   2.454


  5 in total

1.  The Effect of the Length and Distribution of Implants for Fixed Prosthetic Reconstructions in the Atrophic Posterior Maxilla: A Finite Element Analysis.

Authors:  Brunilda Gashi Cenkoglu; Nilufer Bolukbasi Balcioglu; Tayfun Ozdemir; Eitan Mijiritsky
Journal:  Materials (Basel)       Date:  2019-08-11       Impact factor: 3.623

2.  Development of a Knee Joint CT-FEM Model in Load Response of the Stance Phase During Walking Using Muscle Exertion, Motion Analysis, and Ground Reaction Force Data.

Authors:  Kunihiro Watanabe; Hirotaka Mutsuzaki; Takashi Fukaya; Toshiyuki Aoyama; Syuichi Nakajima; Norio Sekine; Koichi Mori
Journal:  Medicina (Kaunas)       Date:  2020-01-29       Impact factor: 2.430

3.  Consequences of Peri-Implant Bone Loss in the Occlusal Load Transfer to the Supporting Bone in terms of Magnitude of Stress, Strain, and Stress Distribution: A Finite Element Analysis.

Authors:  Esteban Pérez-Pevida; David Chávarri-Prado; Markel Diéguez-Pereira; Alejandro Estrada-Martínez; Oier Montalbán-Vadillo; Antonio Jiménez-Garrudo
Journal:  Biomed Res Int       Date:  2021-09-01       Impact factor: 3.411

4.  Stress Distribution Analysis of Threaded Implants for Digital Dentistry.

Authors:  Seokho Ahn; Jaesung Kim; Seok Chan Jeong; Myungil Kim; Cheolyoung Kim; Dongki Park
Journal:  Int J Environ Res Public Health       Date:  2022-10-04       Impact factor: 4.614

Review 5.  Clinical Comparation of Extra-Short (4 mm) and Long (>8 mm) Dental Implants Placed in Mandibular Bone: A Systematic Review and Metanalysis.

Authors:  Vittorio Moraschini; Carlos Fernando de Almeida Barros Mourão; Pietro Montemezzi; Ingrid Chaves Cavalcante Kischinhevsky; Daniel Costa Ferreira de Almeida; Kayvon Javid; Jamil Awad Shibli; José Mauro Granjeiro; Monica Diuana Calasans-Maia
Journal:  Healthcare (Basel)       Date:  2021-03-12
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.