| Literature DB >> 31124504 |
Ruchir Tewari1, Parijat Chandra1, Ramesh Agarwal2, Rajvardhan Azad1.
Abstract
Purpose: To compare the outcomes of conventional laser photocoagulation versus additional posterior barrage laser in advanced stage 3 retinopathy of prematurity (ROP).Entities:
Keywords: Laser barrage; laser treatment; retinopathy of prematurity
Mesh:
Year: 2019 PMID: 31124504 PMCID: PMC6552574 DOI: 10.4103/ijo.IJO_1608_18
Source DB: PubMed Journal: Indian J Ophthalmol ISSN: 0301-4738 Impact factor: 1.848
Figure 1(a) Technique of barrage laser. Left eye of a 34-week post menstrual age baby showing zone 2 posterior stage 3 ROP with plus disease. Posterior barrage laser spots are visible in between the tortuous vessels. (b) Image analysis: Fovea is represented by the white dot. A - Inter-arcade distance at 2 disc diameter from the temporal edge of disc. B - Inter-arcade distance at 4 disc diameter from the temporal edge of the disc. C – Angle subtended by the temporal vessels from the fovea at the center of the disc. D - Disc–fovea distance. E - Fovea–ridge distance. D + E - Disc–ridge distance
Figure 2Number of eyes achieving regression in both groups. More eyes achieved regression in barrage laser group at 2 weeks (P = 0.184) and 4 weeks (P = 0.024) compared to standard laser group
Figure 3(a) At 3 months follow-up, ridge remnants persist in the right eye. (b) The left eye shows barrage laser scars with complete ridge regression
Figure 4(a) 3 months after laser, right eye shows uneventful regression; (b) Left eye has developed tractional detachment that is limited by barrage laser scars. Significant constriction of temporal arcades and foveal drag denoted by increased disc fovea distance is also noted
Comparison of baseline and 3-months post laser data between groups using Independent samples t-test and intragroup using student t-test
| Parameter | Baseline (mm; mean±SD) | 3-months follow-up (mm; mean±SD) | Intragroup comparison: Baseline vs. 3 months | |||||
|---|---|---|---|---|---|---|---|---|
| Barrage laser ( | Standard laser ( | Barrage laser ( | Standard laser ( | Barrage Laser | Standard laser | |||
| Disc fovea distance | 4.532±0.591 | 4.392±0.696 | 0.421 | 4.602±0.632 | 4.274±0.616 | 0.113 | 0.415 | 0.317 |
| Fovea ridge distance | 8.158±1.972 | 9.192±1.64 | 0.087 | 8.484±2.02 | 9.137±1.753 | 0.294 | 0.098 | 0.801 |
| Disc ridge distance | 12.726±2.18 | 13.585±1.965 | 0.21 | 13.086±2.37 | 13.421±2.05 | 0.645 | 0.125 | 0.585 |
| IAD at 2DD | 7.049±1.26 | 7.188±1.054 | 0.714 | 6.439±1.41 | 7.111±1.085 | 0.109 | 0.001 | 0.449 |
| IAD at 4 DD | 8.297±1.39 | 8.486±1.145 | 0.65 | 7.49±1.56 | 7.724±1.244 | 0.613 | 0.0004 | 0.0001 |
| IAA at fovea* (degrees) | 94.89±13.52 | 96.561±7.784 | 0.643 | 89.282±16.59 | 94.588±8.876 | 0.227 | 0.004 | 0.041 |
IAD – Inter-arcade distance, IAA – Inter-arcade angle, DD – Disc diameters; *Inter-arcade angle measured in degrees, rest measurements in millimeters. Data analyzed using Independent samples t-test and student t test