Literature DB >> 31122829

Agreement Between 2 Segmental Bioimpedance Devices, BOD POD, and DXA in Obese Adults.

Brett S Nickerson1, Cherilyn N McLester2, John R McLester2, Brian M Kliszczewicz2.   

Abstract

This study examined the agreement between 2 segmental bioimpedance analysis (BIA) devices, air displacement plethysmography (BOD POD), and dual energy X-ray absorptiometry (DXA) for estimating body composition in obese adults. Fifty obese adults (25 men and 25 women; age = 34.20 ± 11.19 years; BMI = 36.14 ± 5.33 kg/m2) had their body fat percentage (BF%) and fat-free mass (FFM) evaluated with 2 segmental BIA devices (InBody 230 and InBody 720), BOD POD, and DXA (Lunar iDXA). Body composition via the BOD POD was determined using the Siri equation whereas manufacturer-based equations generated metrics (ie, BF% and FFM) for the InBody devices. The effect size of the mean differences for all BF% and FFM comparisons were trivial (Cohen's d < 0.20). The standard error of estimate (SEE), total error (TE), and 95% limits of agreement (LOAs) were low for both segmental BIA devices when compared to DXA (SEE < 2.26% and 2.35 kg; TE < 2.58% and 2.66 kg; 95% LOAs < ± 4.94% and 4.86kg). The error for BOD POD was also low when compared to DXA (SEE = 2.39% and 2.57 kg; TE = 2.34% and 2.56 kg; 95% LOAs = 4.63% and 5.06 kg). Validity statistics were slightly higher, but considered acceptable, when comparing the segmental BIA devices against BOD POD (SEE < 3.37% and 3.63 kg; TE < 3.44% and 3.79 kg; 95% LOAs < ± 6.62% and 7.19 kg). Lastly, the 2 segmental BIA devices produced nearly identical validity statistics when compared to each other. However, both BIA devices revealed proportional bias for BF% and FFM when compared to the BOD POD and DXA (all p < 0.05). The current study's findings indicate the InBody 230 is interchangeable with the InBody 720 in obese adults. Also, the trivial effect size, when compared against the BOD POD and DXA, suggest the InBody devices could be used for estimating group BF% and FFM. In contrast, the significant proportional bias demonstrates the BIA devices are not acceptable for individual estimates of body composition in an obese clinical population.
Copyright © 2019 The International Society for Clinical Densitometry. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Air displacement plethysmography; DXA; bioimpedance; body composition; obese

Mesh:

Year:  2019        PMID: 31122829     DOI: 10.1016/j.jocd.2019.04.005

Source DB:  PubMed          Journal:  J Clin Densitom        ISSN: 1094-6950            Impact factor:   2.617


  6 in total

1.  The Relationship between Serum Insulin-Like Growth Factor-1 Levels and Body Composition Changes after Sleeve Gastrectomy.

Authors:  Masahiro Ohira; Yasuhiro Watanabe; Takashi Yamaguchi; Hiroki Onda; Shuhei Yamaoka; Kazuki Abe; Shoko Nakamura; Shou Tanaka; Naoyuki Kawagoe; Taiki Nabekura; Atsuhito Saiki; Takashi Oshiro; Daiji Nagayama; Ichiro Tatsuno
Journal:  Obes Facts       Date:  2021-10-14       Impact factor: 3.942

2.  Differences between Four Skinfold Calipers in the Assessment of Adipose Tissue in Young Adult Healthy Population.

Authors:  Francisco Esparza-Ros; Ana Catarina Moreira; Raquel Vaquero-Cristóbal; Carlos Barrigas; Mario Albaladejo-Saura; Filomena Vieira
Journal:  Nutrients       Date:  2022-05-16       Impact factor: 6.706

3.  Relative Accuracy of Bioelectrical Impedance Analysis for Assessing Body Composition in Children With Severe Obesity.

Authors:  Soofia Khan; Stavra A Xanthakos; Lindsey Hornung; Catalina Arce-Clachar; Robert Siegel; Heidi J Kalkwarf
Journal:  J Pediatr Gastroenterol Nutr       Date:  2020-06       Impact factor: 3.288

4.  Markers of muscle damage and strength performance in professional football (soccer) players during the competitive period.

Authors:  Vladimir Khaitin; Eduard Bezuglov; Artemii Lazarev; Sergey Matveev; Olga Ivanova; Nicola Maffulli; Evgeny Achkasov
Journal:  Ann Transl Med       Date:  2021-01

5.  Trajectory Analysis and Predictors of the Percentage of Body Fat Among Chinese Sleeve Gastrectomy Patients.

Authors:  Kang Zhao; Xinyi Xu; Hanfei Zhu; Ziqi Ren; Tianzi Zhang; Ningli Yang; Shuqin Zhu; Qin Xu
Journal:  Diabetes Metab Syndr Obes       Date:  2021-12-29       Impact factor: 3.168

6.  Performance of Bioelectrical Impedance and Anthropometric Predictive Equations for Estimation of Muscle Mass in Chronic Kidney Disease Patients.

Authors:  Natália Tomborelli Bellafronte; Lorena Vega-Piris; Guillermina Barril Cuadrado; Paula Garcia Chiarello
Journal:  Front Nutr       Date:  2021-05-21
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.