Metal Artifact Reduction in Cardiovascular MRI for Accurate Myocardial Scar Assessment in Patients With Cardiac Implantable Electronic Devices.

Mason Runge1, El-Sayed H Ibrahim2, Frank Bogun3, Anil Attili4, Maryam Ghadimi Mahani5, Yuxi Pang4, Laura Horwood3, Thomas L Chenevert4, Jadranka Stojanovska4.   

Abstract

OBJECTIVE. An important application of late gadolinium enhancement (LGE) cardiac MRI is accurate assessment of myocardial scar before ablation. However, this is often limited in patients with cardiac implantable electronic devices (CIEDs) because of metal device-induced artifacts. The purpose of this study was to determine whether a modified wideband inversion recovery (IR) LGE MRI technique decreases artifact volume to allow the assessment of myocardial scar. SUBJECTS AND METHODS. Fifty patients (17 women and 33 men; mean age ± SD, 61 ± 12 years; mean ejection fraction ± SD, 35.9% ± 13.3%) with CIEDs underwent cardiac MRI using conventional and modified wideband IR LGE techniques before ablation. The volume of device-induced artifact was quantified and stratified by tertiles on mild, moderate, and severe. Ordinal logistic regression analysis assessed the association between artifact volume on conventional and wideband images adjusted for patients' demographics. RESULTS. Conventional LGE MRI resulted in device-induced hyperintense artifacts that obscured ventricular segments in 32 of 50 (64%) cases. Wideband LGE MRI significantly reduced severe artifact volume (p < 0.0001) and completely resolved all mild and most moderate artifacts. Overall, wideband techniques resulted in a 56% reduction in total artifact volume for the cohort (p < 0.0001). The wideband LGE MRI sequence minimized artifacts in the most commonly obscured segments on the conventional LGE MRI sequence, with persistent artifacts in seven, eight, and four of 32 cases at the basal anterior, midventricular anterior, and midventricular anteroseptal segments, respectively. CONCLUSION. The modified wideband IR technique completely resolves mild and moderate device-induced hyperintense artifacts and significantly reduces the volume of severe artifact to allow accurate identification of myocardial scar in patients with CIEDs before ablation.

Entities:  

Keywords:  cardiac-implantable electronic device (CIED); late gadolinium enhancement; metal artifact; myocardial scar; ventricular tachycardia

Year:  2019        PMID: 31120781     DOI: 10.2214/AJR.19.21187

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  3 in total

1.  Primer on Commonly Occurring MRI Artifacts and How to Overcome Them.

Authors:  Chikara Noda; Bharath Ambale Venkatesh; Jennifer D Wagner; Yoko Kato; Jason M Ortman; João A C Lima
Journal:  Radiographics       Date:  2022-04-22       Impact factor: 6.312

2.  Clearing the Path to Optimal Care in Patients with Non-MRI-conditional Cardiac Devices.

Authors:  Ronald M Peshock
Journal:  Radiol Cardiothorac Imaging       Date:  2020-10-29

3.  Pre-procedural image-guided versus non-image-guided ventricular tachycardia ablation-a review.

Authors:  A A Hendriks; Z Kis; M Glisic; W M Bramer; T Szili-Torok
Journal:  Neth Heart J       Date:  2020-11       Impact factor: 2.380

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.