| Literature DB >> 31118001 |
Peng Zhang1, Hao Hai2, Dongxu Sun2, Weihua Yuan3, Weijie Liu2, Ruru Ding2, Mengting Teng2, Lin Ma2, Jun Tian4, Caifa Chen5.
Abstract
BACKGROUND: The potassium dichromate oxidation method used in determination of alcohols in fermentation has two major disadvantages. This method cannot be used to determine alcohols in raw fermentation broth samples, which often contain various reducing sugars. The method is not environment friendly due to the carcinogenicity of Cr (VI) used.Entities:
Mesh:
Substances:
Year: 2019 PMID: 31118001 PMCID: PMC6532202 DOI: 10.1186/s12896-019-0525-7
Source DB: PubMed Journal: BMC Biotechnol ISSN: 1472-6750 Impact factor: 2.563
Fig. 1Standard curves of glucose and ethanol (a DNS method for glucose; b potassium permanganate method for glucose; c: potassium permanganate method for ethanol; A526 = A526 before the reaction – A526 after the reaction)
Fig. 2The stability of oxidization (a The stability of DNS oxidization; b The stability of potassium permanganate oxidization; A526 = A526 before the reaction – A526 after the reaction)
Fig. 3The effect of different factors on the determination of glucose and ethanol (a The effect of different factors on the determination of glucose with DNS reaction; b The effect of CTAB in potassium permanganate reaction; c he effect of trichloroacetic acid in potassium permanganate reaction; A526 = A526 before the reaction – A526 after the reaction)
Determination of accuracy of the RSSAA method
| NO. | Ethanol concentration spiked | Ethanol concentration detecteda | Detection accuracy |
|---|---|---|---|
| (%,V/V) | (%,V/V) | (%) | |
| 1 | 1.93 | 2.01 ± 0.09 | 104.1 ± 4.7 |
| 2 | 3.79 | 3.85 ± 0.12 | 101.6 ± 3.2 |
| 3 | 5.57 | 5.98 ± 0.28 | 107.4 ± 5 |
| 4 | 7.3 | 7.32 ± 0.15 | 100.3 ± 2.1 |
| 5 | 8.95 | 9.08 ± 0.09 | 101.5 ± 1 |
| 6 | 10.55 | 10.61 ± 0.11 | 100.6 ± 1 |
| 7 | 12.11 | 12 ± 0.12 | 99.1 ± 1 |
| 8 | 13.59 | 13.72 ± 0.25 | 101 ± 1.8 |
| 9 | 15.02 | 15.12 ± 0.21 | 100.7 ± 1.4 |
| 10 | 16.42 | 16.44 ± 0.02 | 100.1 ± 0.1 |
aThe values = measured values - 1.5% (ethanol concentration in PS sample)
Fig. 4The application of our new method to monitor the concentrations of total alcohols and remaining reducing sugars during a fermentation process
Fig. 5Comparison of the new method and other methods. Maotai wine from China, b Jacob’s Creek from Australia, c Absolut Vodka from Sweden, d Taster red wine from Chile, e Macaulay Whisky from Scotland, f Qingdao beer from China, g fermentation broth)