Brody H Foy1, Marcia Soares2, Rafel Bordas1,3, Matthew Richardson2, Alex Bell2, Amisha Singapuri2, Beverley Hargadon2, Christopher Brightling2, Kelly Burrowes4, David Kay1, John Owers-Bradley5, Salman Siddiqui2. 1. Department of Computer Science, University of Oxford, Oxfordshire, United Kingdom. 2. College of Life Sciences and Respiratory Research Theme, National Institute for Health Research Biomedical Research Centre, University of Leicester, Leicester, United Kingdom. 3. Roxar Software Solutions, Oxford, United Kingdom. 4. Department of Chemical and Materials Engineering, University of Auckland, Auckland, New Zealand; and. 5. School of Physics and Astronomy, University of Nottingham, Nottingham, United Kingdom.
Abstract
Rationale: Asthma is characterized by disease within the small airways. Several studies have suggested that forced oscillation technique-derived resistance at 5 Hz (R5) - resistance at 20 Hz (R20) is a measure of small airway disease; however, there has been limited validation of this measurement to date. Objectives: To validate the use of forced oscillation R5 - R20 as a measure of small airway narrowing in asthma, and to investigate the role that small airway narrowing plays in asthma. Methods: Patient-based complete conducting airway models were generated from computed tomography scans to simulate the impact of different degrees of airway narrowing at different levels of the airway tree on forced oscillation R5 - R20 (n = 31). The computational models were coupled with regression models in an asthmatic cohort (n = 177) to simulate the impact of small airway narrowing on asthma control and quality of life. The computational models were used to predict the impact on small airway narrowing of type-2 targeting biologics using pooled data from two similarly design randomized, placebo-controlled biologic trials (n = 137).Measurements and Main Results: Simulations demonstrated that narrowing of the small airways had a greater impact on R5 - R20 than narrowing of the larger airways and was associated (above a threshold of approximately 40% narrowing) with marked deterioration in both asthma control and asthma quality of life, above the minimal clinical important difference. The observed treatment effect on R5 - R20 in the pooled trials equated to a predicted small airway narrowing reversal of approximately 40%.Conclusions: We have demonstrated, using computational modeling, that forced oscillation R5 - R20 is a direct measure of anatomical narrowing in the small airways and that small airway narrowing has a marked impact on both asthma control and quality of life and may be modified by biologics.
Rationale: Asthma is characterized by disease within the small airways. Several studies have suggested that forced oscillation technique-derived resistance at 5 Hz (R5) - resistance at 20 Hz (R20) is a measure of small airway disease; however, there has been limited validation of this measurement to date. Objectives: To validate the use of forced oscillation R5 - R20 as a measure of small airway narrowing in asthma, and to investigate the role that small airway narrowing plays in asthma. Methods:Patient-based complete conducting airway models were generated from computed tomography scans to simulate the impact of different degrees of airway narrowing at different levels of the airway tree on forced oscillation R5 - R20 (n = 31). The computational models were coupled with regression models in an asthmatic cohort (n = 177) to simulate the impact of small airway narrowing on asthma control and quality of life. The computational models were used to predict the impact on small airway narrowing of type-2 targeting biologics using pooled data from two similarly design randomized, placebo-controlled biologic trials (n = 137).Measurements and Main Results: Simulations demonstrated that narrowing of the small airways had a greater impact on R5 - R20 than narrowing of the larger airways and was associated (above a threshold of approximately 40% narrowing) with marked deterioration in both asthma control and asthma quality of life, above the minimal clinical important difference. The observed treatment effect on R5 - R20 in the pooled trials equated to a predicted small airway narrowing reversal of approximately 40%.Conclusions: We have demonstrated, using computational modeling, that forced oscillation R5 - R20 is a direct measure of anatomical narrowing in the small airways and that small airway narrowing has a marked impact on both asthma control and quality of life and may be modified by biologics.
Entities:
Keywords:
asthma; forced oscillation technique; imaging; integrative modelling; small airways
Authors: Merryn H Tawhai; Peter Hunter; Juerg Tschirren; Joseph Reinhardt; Geoffrey McLennan; Eric A Hoffman Journal: J Appl Physiol (1985) Date: 2004-08-20
Authors: Richard J Russell; Latifa Chachi; J Mark FitzGerald; Vibeke Backer; Ronald Olivenstein; Ingrid L Titlestad; Charlotte Suppli Ulrik; Timothy Harrison; Dave Singh; Rekha Chaudhuri; Brian Leaker; Lorcan McGarvey; Salman Siddiqui; Millie Wang; Martin Braddock; Lars H Nordenmark; David Cohen; Himanshu Parikh; Gene Colice; Christopher E Brightling Journal: Lancet Respir Med Date: 2018-05-21 Impact factor: 30.700
Authors: S Gonem; S Natarajan; D Desai; S Corkill; A Singapuri; P Bradding; P Gustafsson; R Costanza; R Kajekar; H Parmar; C E Brightling; S Siddiqui Journal: Clin Exp Allergy Date: 2014-04 Impact factor: 5.018
Authors: Rafel Bordas; Christophe Lefevre; Bart Veeckmans; Joe Pitt-Francis; Catalin Fetita; Christopher E Brightling; David Kay; Salman Siddiqui; Kelly S Burrowes Journal: PLoS One Date: 2015-12-11 Impact factor: 3.240
Authors: Hanna M Knihtilä; Benjamin J Stubbs; Vincent J Carey; Nancy Laranjo; Su H Chu; Rachel S Kelly; Robert S Zeiger; Leonard B Bacharier; George T O'Connor; Jessica Lasky-Su; Scott T Weiss; Augusto A Litonjua Journal: J Allergy Clin Immunol Date: 2021-01-22 Impact factor: 14.290