Characterization and Control of a Pneumatic Motor for MR-conditional Robotic Applications.

Yue Chen1, Isuru S Godage1, Zion Tsz Ho Tse2, Robert J Webster1, Eric J Barth1.   

Abstract

Magnetic Resonance (MR) guided interventional robots have recently been developed for a variety of surgeries, such as biopsy, ablation, and brachytherapy. The actuators and encoders that power and track such robots must be MR-conditional. In this paper, we propose an MR-conditional pneumatic motor with an integrated and custom-built fiber-optical encoder that provides powerful and accurate actuation. The motor is coupled with a modular plastic gearbox that provides a variety of gear ratio options so that the motor can be adapted to application requirements. With a 100:1 gear reduction at 0.55 MPa, the motor achieves 460 mNm stall torque and 370 rpm no-load speed, which leads to the peak output power of 6W. The motor has the bandwidth of approximately 1.1 Hz and 3.5 Hz when connected to 8 m and 0.2 m air hoses, respectively. The motor was tested in a 3T MRI scanner. No image artifact was observed and maximum signal to noise ratio (SNR) variation was less than 5%. Different from most of the existing MR-conditional pneumatic actuators, the proposed motor shape is more like the traditional electric motors, which offers more flexibility in the MR-conditional robot design.

Entities:  

Keywords:  MR-conditional; Magnetic Resonance Imaging (MRI); optical encoding; pneumatic motor

Year:  2017        PMID: 31105420      PMCID: PMC6519483          DOI: 10.1109/TMECH.2017.2767906

Source DB:  PubMed          Journal:  IEEE ASME Trans Mechatron        ISSN: 1083-4435            Impact factor:   5.303


  3 in total

1.  MR-conditional steerable needle robot for intracerebral hemorrhage removal.

Authors:  Yue Chen; Isuru S Godage; Saikat Sengupta; Cindy Lin Liu; Kyle D Weaver; Eric J Barth
Journal:  Int J Comput Assist Radiol Surg       Date:  2018-09-01       Impact factor: 2.924

Review 2.  Minimally Invasive Intracerebral Hemorrhage Evacuation: A review.

Authors:  Mishek J Musa; Austin B Carpenter; Christopher Kellner; Dimitri Sigounas; Isuru Godage; Saikat Sengupta; Chima Oluigbo; Kevin Cleary; Yue Chen
Journal:  Ann Biomed Eng       Date:  2022-02-28       Impact factor: 3.934

3.  A Fully Actuated Robotic Assistant for MRI-Guided Precision Conformal Ablation of Brain Tumors.

Authors:  Gang Li; Niravkumar A Patel; Everette C Burdette; Julie G Pilitsis; Hao Su; Gregory S Fischer
Journal:  IEEE ASME Trans Mechatron       Date:  2020-07-29       Impact factor: 5.303

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.