Literature DB >> 31104709

Automatic matching of computed tomography and stereolithography data.

S Woo1, S Lee2, J Chae3, J Rim4, J Lee5, J Seo6, C Lee7.   

Abstract

BACKGROUND AND
OBJECTIVE: Computed tomography (CT) is one of the most frequently used medical imaging methods. An important application area of CT is dental implants, which require precise inspection and analysis of oral structures. Since CT provides a precise 3D model of the teeth, bones and nerves, it can be used as a surgical guide for dental implants. Along with CT, optical 3D images called stereolithography (STL) have also been widely used. STL images obtained from optical 3D images can be used to show the 3D surfaces of oral structures. Since CT data and STL data deploy different technologies to obtain dental information, we can obtain more accurate dental implants by combining the two datasets. Since the two datasets are acquired by using different sensors, the datasets need to be registered.
METHODS: An automatic matching algorithm is proposed for CT and STL image registration, which is based on depth maps and maximum intensity projection. Then, fine tuning was performed based on volume matching.
RESULTS: When applied to real-world databases, the proposed method provided an average matching error of 2.7 mm for the upper jaw and 2.3 mm for the lower jaw with an average processing time of about 19 s.
CONCLUSIONS: The proposed method performs accurate registration of CT and STL.
Copyright © 2019 Elsevier B.V. All rights reserved.

Keywords:  Optical imaging/oct/dot; Registration; Surgical guidance/navigation; Tooth; X-ray imaging and computed tomography

Mesh:

Year:  2019        PMID: 31104709     DOI: 10.1016/j.cmpb.2019.04.003

Source DB:  PubMed          Journal:  Comput Methods Programs Biomed        ISSN: 0169-2607            Impact factor:   5.428


  2 in total

1.  Evaluation of different registration methods and dental restorations on the registration duration and accuracy of cone beam computed tomography data and intraoral scans: a retrospective clinical study.

Authors:  Xing-Yu Piao; Ji-Man Park; Hannah Kim; Youngjun Kim; June-Sung Shim
Journal:  Clin Oral Investig       Date:  2022-05-10       Impact factor: 3.606

2.  Dental implant location via surface scanner: a pilot study.

Authors:  Miao Zhou; Hui Zhou; Shu-Yi Li; Yuan-Ming Geng
Journal:  BMC Oral Health       Date:  2020-11-04       Impact factor: 2.757