Literature DB >> 31093519

Calibration of fluorescence imaging for tumor surgical margin delineation: multistep registration of fluorescence and histological images.

Yang Jiang1, Emily J Girard2, Fiona Pakiam2, Eric J Seibel1.   

Abstract

Although a greater extent of tumor resection is important for patients' survival, complete tumor removal, especially tumor margins, remains challenging due to the lack of sensitivity and specificity of current surgical guidance techniques at the margins. Intraoperative fluorescence imaging with targeted fluorophores is promising for tumor margin delineation. To verify the tumor margins detected by the fluorescence images, it is necessary to register fluorescence with histological images, which provide the ground truth for tumor regions. However, current registration methods compare fluorescence images to a single-layer histological slide, which is selected subjectively and represents a single plane of the three-dimensional tumor. A multistep pipeline is established to correlate fluorescence images to stacked histological images, including fluorescence calibration and multistep registration. Multiple histological slices are integrated as a two-dimensional (2-D) tumor map using optical attenuation model and average intensity projection. A BLZ-100-labeled medulloblastoma mouse model is used to test the whole framework. On average, the synthesized 2-D tumor map outperforms the selected best slide as ground truth [Dice similarity coefficient (DSC): 0.582 versus 0.398, with significant differences; mean area under the curve (AUC) of the receiver operating characteristic curve: 88% versus 85.5%] and the randomly selected slide as ground truth (DSC: 0.582 versus 0.396 with significant differences; mean AUC: 88% versus 84.1% with significant differences), which indicates our pipeline is reliable and can be applied to investigate targeted fluorescence probes in tumor margin detection. Following this proposed pipeline, BLZ-100 shows enhancement in both tumor cores and tumor margins (mean target-to-background ratio: 8.64 ± 5.76 and 4.82 ± 2.79 , respectively).

Entities:  

Keywords:  fluorescence guided surgery; image registration; molecular imaging; multimodal scanning fiber endoscope; surgical margin delineation

Year:  2019        PMID: 31093519      PMCID: PMC6511232          DOI: 10.1117/1.JMI.6.2.025005

Source DB:  PubMed          Journal:  J Med Imaging (Bellingham)        ISSN: 2329-4302


  40 in total

1.  Compact instrument for fluorescence image-guided surgery.

Authors:  Xinghua Wang; Srabani Bhaumik; Qing Li; V Paul Staudinger; Siavash Yazdanfar
Journal:  J Biomed Opt       Date:  2010 Mar-Apr       Impact factor: 3.170

Review 2.  Scanning fiber endoscopy with highly flexible, 1 mm catheterscopes for wide-field, full-color imaging.

Authors:  Cameron M Lee; Christoph J Engelbrecht; Timothy D Soper; Fritjof Helmchen; Eric J Seibel
Journal:  J Biophotonics       Date:  2010-06       Impact factor: 3.207

3.  Determination of reduced scattering coefficient of biological tissue from a needle-like probe.

Authors:  Maureen Johns; Cole Giller; Dwight German; Hanli Liu
Journal:  Opt Express       Date:  2005-06-27       Impact factor: 3.894

Review 4.  Light-emitting diodes (LEDs) in dermatology.

Authors:  Daniel Barolet
Journal:  Semin Cutan Med Surg       Date:  2008-12

5.  Mayo Clinic consensus recommendations for the depth of excision in primary cutaneous melanoma.

Authors:  Travis E Grotz; Svetomir N Markovic; Lori A Erickson; William S Harmsen; Marianne Huebner; David R Farley; Barbara A Pockaj; John H Donohue; Franklin H Sim; Clive S Grant; Sanjay P Bagaria; Thomas C Shives; Charles M Balch; James W Jakub
Journal:  Mayo Clin Proc       Date:  2011-06       Impact factor: 7.616

6.  Fluorescence-guided surgery with 5-aminolevulinic acid for resection of malignant glioma: a randomised controlled multicentre phase III trial.

Authors:  Walter Stummer; Uwe Pichlmeier; Thomas Meinel; Otmar Dieter Wiestler; Friedhelm Zanella; Hans-Jürgen Reulen
Journal:  Lancet Oncol       Date:  2006-05       Impact factor: 41.316

7.  Use of in vivo near-infrared laser confocal endomicroscopy with indocyanine green to detect the boundary of infiltrative tumor.

Authors:  Nikolay L Martirosyan; Daniel D Cavalcanti; Jennifer M Eschbacher; Peter M Delaney; Adrienne C Scheck; Mohammed G Abdelwahab; Peter Nakaji; Robert F Spetzler; Mark C Preul
Journal:  J Neurosurg       Date:  2011-09-16       Impact factor: 5.115

8.  A multivariate analysis of 416 patients with glioblastoma multiforme: prognosis, extent of resection, and survival.

Authors:  M Lacroix; D Abi-Said; D R Fourney; Z L Gokaslan; W Shi; F DeMonte; F F Lang; I E McCutcheon; S J Hassenbusch; E Holland; K Hess; C Michael; D Miller; R Sawaya
Journal:  J Neurosurg       Date:  2001-08       Impact factor: 5.115

9.  Fluorescence-guided resection of glioblastoma multiforme by using 5-aminolevulinic acid-induced porphyrins: a prospective study in 52 consecutive patients.

Authors:  W Stummer; A Novotny; H Stepp; C Goetz; K Bise; H J Reulen
Journal:  J Neurosurg       Date:  2000-12       Impact factor: 5.115

10.  Independent association of extent of resection with survival in patients with malignant brain astrocytoma.

Authors:  Matthew J McGirt; Kaisorn L Chaichana; Muraya Gathinji; Frank J Attenello; Khoi Than; Alessandro Olivi; Jon D Weingart; Henry Brem; Alf Redo Quiñones-Hinojosa
Journal:  J Neurosurg       Date:  2009-01       Impact factor: 5.115

View more
  3 in total

1.  Intensity-based registration of bright-field and second-harmonic generation images of histopathology tissue sections.

Authors:  Adib Keikhosravi; Bin Li; Yuming Liu; Kevin W Eliceiri
Journal:  Biomed Opt Express       Date:  2019-12-09       Impact factor: 3.732

Review 2.  Protein scaffolds: antibody alternatives for cancer diagnosis and therapy.

Authors:  Renli Luo; Hongguang Liu; Zhen Cheng
Journal:  RSC Chem Biol       Date:  2022-05-25

3.  Fluorescence Spectroscopy Study of Protoporphyrin IX in Optical Tissue Simulating Liquid Phantoms.

Authors:  Huihui Lu; Francesco Floris; Marc Rensing; Stefan Andersson-Engels
Journal:  Materials (Basel)       Date:  2020-05-02       Impact factor: 3.623

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.