Literature DB >> 310932

Estimation of beat-to-beat stroke volume from the pulmonary arterial pressure contour in man.

A F DeLoskey, W W Nichols, C R Conti, C J Pepine.   

Abstract

Entities:  

Mesh:

Year:  1978        PMID: 310932     DOI: 10.1007/bf02442451

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


× No keyword cloud information.
  13 in total

1.  Quantitation of beat-to-beat changes in stroke volume from the aortic pulse contour in man.

Authors:  H R WARNER; H J C SWAN; D C CONNOLLY; R G TOMPKINS; E H WOOD
Journal:  J Appl Physiol       Date:  1953-03       Impact factor: 3.531

2.  Evaluation of an electromagnetic catheter tip velocity-sensitive blood flow probe.

Authors:  R F Bond; C A Barefoot
Journal:  J Appl Physiol       Date:  1967-09       Impact factor: 3.531

3.  Estimation of stroke volume from the pulmonary artery pressure record.

Authors:  A A Zacharoulis; C J Mills; I T Gabe; J P Shillingford
Journal:  Cardiovasc Res       Date:  1974-07       Impact factor: 10.787

Review 4.  Continuous cardiac output derived from the aortic pressure waveform: a review of current methods.

Authors:  W W Nichols
Journal:  Biomed Eng       Date:  1973-09

5.  Estimation of stroke volume from the central arterial pressure contour in postoperative patients.

Authors:  N T Kouchoukos; L C Sheppard; D A McDonald; J W Kirklin
Journal:  Surg Forum       Date:  1969

6.  Estimation of stroke volume in the dog by a pulse contour method.

Authors:  N T Kouchoukos; L C Sheppard; D A McDonald
Journal:  Circ Res       Date:  1970-05       Impact factor: 17.367

7.  Pressure methods for estimating right and left ventricular stroke volumes.

Authors:  A A Cibulski; P H Lehan; H K Hellems
Journal:  Am J Physiol       Date:  1973-12

8.  Velocity profiles in the main pulmonary artery of dogs and man, measured with a thin-film resistance anemometer.

Authors:  S R Reuben; J P Swadling; G J de Lee
Journal:  Circ Res       Date:  1970-12       Impact factor: 17.367

9.  Physiologic evaluation of a catheter tip electromagnetic velocity probe. A new instrument.

Authors:  J R Warbasse; B H Hellman; R E Gillilan; R R Hawley; H I Babitt
Journal:  Am J Cardiol       Date:  1969-03       Impact factor: 2.778

10.  Input impedance of the systemic circulation in man.

Authors:  W W Nichols; C R Conti; W E Walker; W R Milnor
Journal:  Circ Res       Date:  1977-05       Impact factor: 17.367

View more
  2 in total

Review 1.  Continuous and less invasive central hemodynamic monitoring by blood pressure waveform analysis.

Authors:  Ramakrishna Mukkamala; Da Xu
Journal:  Am J Physiol Heart Circ Physiol       Date:  2010-07-09       Impact factor: 4.733

2.  Continuous cardiac output and left atrial pressure monitoring by long time interval analysis of the pulmonary artery pressure waveform: proof of concept in dogs.

Authors:  Da Xu; N Bari Olivier; Ramakrishna Mukkamala
Journal:  J Appl Physiol (1985)       Date:  2008-12-04
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.