Comparison of Contrast-Enhanced Mammography With Conventional Digital Mammography in Breast Cancer Screening: A Pilot Study.

Geunwon Kim1, Jordana Phillips2, Elodia Cole3, Alexander Brook1, Tejas Mehta1, Priscilla Slanetz1, Michael D C Fishman4, Evguenia Karimova1, Rashmi Mehta1, Parisa Lotfi1, Nancy Resteghini5, Sean Raj6, Vandana Dialani1.   

Abstract

PURPOSE: To perform a pilot evaluation of contrast-enhanced mammography (CEM) for screening to determine whether it can improve accuracy and reader confidence in diagnosis. METHODS AND MATERIALS: This institutional review board-approved reader study was comprised of 64 de-identified CEM cases acquired from December 1, 2014, to June 7, 2016, including 48 negative, 5 biopsy-proven benign, and 11 biopsy-proven malignancies. Negative cases were followed for at least 2 years without evidence of cancer. Ten breast imagers of varying experience first rated the low-energy (LE) mammogram and then the CEM examination using BI-RADS categories and a 5-point Likert scale for confidence in diagnosis.
RESULTS: There were 635 out a total possible 640 complete reader interpretations included in this analysis. The remaining five incomplete interpretations were excluded. Median sensitivity and specificity improved with the addition of CEM (sensitivity: 0.86 [95% confidence interval {CI}: 0.74-0.95] versus 1 [95% CI: 0.83-1.00], specificity: 0.85 [95% CI: 0.64-0.94] versus 0.88 [95% CI: 0.80-0.92]). Individual receiver operating characteristic curves showed significant improvement with CEM (mean area under the curve increase = 0.056 [95% CI: 0.015-0.097], P = .002). The addition of CEM significantly improved average confidence in 5 of 10 readers when compared with LE (P < .0001) and improved pooled confidence across all tissue density categories, except the almost entirely fatty category. There was a trend toward improved confidence with increasing tissue density with CEM. Degree of background parenchymal enhancement did not affect readers' level of improvement in confidence when interpreting CEM.
SUMMARY: CEM improved reader performance and confidence compared with viewing only LE, suggesting a role for CEM in breast cancer screening for which larger trials are warranted.
Copyright © 2019 American College of Radiology. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  CEM; CESM; Contrast enhanced mammography; breast cancer screening

Year:  2019        PMID: 31092346     DOI: 10.1016/j.jacr.2019.04.007

Source DB:  PubMed          Journal:  J Am Coll Radiol        ISSN: 1546-1440            Impact factor:   5.532


  5 in total

Review 1.  Novel imaging approaches to screen for breast cancer: Recent advances and future prospects.

Authors:  Christopher L Vaughan
Journal:  Med Eng Phys       Date:  2019-10       Impact factor: 2.242

2.  Dual-energy contrast-enhanced spectral mammography (CESM) for breast cancer screening.

Authors:  Vera Sorin; Miri Sklair-Levy
Journal:  Quant Imaging Med Surg       Date:  2019-11

3.  Which clinical, radiological, histological, and molecular parameters are associated with the absence of enhancement of known breast cancers with Contrast Enhanced Digital Mammography (CEDM)?

Authors:  Giulia Bicchierai; Francesco Amato; Bianca Vanzi; Diego De Benedetto; Cecilia Boeri; Ermanno Vanzi; Federica Di Naro; Simonetta Bianchi; Donatello Cirone; Diletta Cozzi; Vittorio Miele; Jacopo Nori
Journal:  Breast       Date:  2020-08-21       Impact factor: 4.380

4.  Radiation Dose of Contrast-Enhanced Mammography: A Two-Center Prospective Comparison.

Authors:  Gisella Gennaro; Andrea Cozzi; Simone Schiaffino; Francesco Sardanelli; Francesca Caumo
Journal:  Cancers (Basel)       Date:  2022-03-31       Impact factor: 6.639

5.  Diagnostic accuracy of contrast-enhanced spectral mammography for breast lesions: A systematic review and meta-analysis.

Authors:  Matteo Basilio Suter; Filippo Pesapane; Giorgio Maria Agazzi; Tania Gagliardi; Olga Nigro; Anna Bozzini; Francesca Priolo; Silvia Penco; Enrico Cassano; Claudio Chini; Alessandro Squizzato
Journal:  Breast       Date:  2020-06-10       Impact factor: 4.380

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.