Knee and hip strength measurements obtained by a hand-held dynamometer stabilized by a belt and an examiner demonstrate parallel reliability but not agreement.

Lidiane L Florencio1, Jaqueline Martins2, Marcelo R B da Silva3, Janaina R da Silva4, Gustavo L Bellizzi5, Débora Bevilaqua-Grossi6.   

Abstract

OBJECTIVES: To verify the intrasession reliability and the agreement between strength measurement of hip and knee muscles using hand-held dynamometer stabilized by a belt or by an examiner.
DESIGN: Test-retest design.
SETTING: Knee and hip muscles strength were measured bilaterally using hand-held dynamometer stabilized by a belt and by an examiner. PARTICIPANTS: 24 young and healthy participants. MAIN OUTCOME MEASURES: The reliability was verified by the intraclass correlation coefficient2,1 and the standard error of measurement. Agreement between stabilization methods was verified by the Bland Altman's method.
RESULTS: Reliability was excellent for all muscle groups when stabilized by a belt (intraclass correlation coefficient = 0.78 to 0.95) and by the examiner (intraclass correlation coefficient = 0.83 to 0.97); standard error of measurement ranged between 1kgf to 4kgf at both methods, but they are proportionally lower when stabilized by the examiner. No agreement between both methods was identified for all knee strength measurements and for bilateral hip flexion, right internal and external rotation and left adduction.
CONCLUSIONS: The hand-held dynamometer is reliable for hip and knee strength evaluation despite of the stabilization method. However, for the majority of the movements, greater strength and lower error are expected when the examiner stabilizes it.
Copyright © 2019 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Hip; Knee; Muscle strength; Reproducibility of results

Mesh:

Year:  2019        PMID: 31091492     DOI: 10.1016/j.ptsp.2019.04.011

Source DB:  PubMed          Journal:  Phys Ther Sport        ISSN: 1466-853X            Impact factor:   2.365


  3 in total

1.  Reliability of hand-held dynamometer in measuring gluteus medius isometric muscle strength in healthy population.

Authors:  Rabail Rani Soomro; Hossein Karimi; Syed Amir Gillani
Journal:  Pak J Med Sci       Date:  2022 May-Jun       Impact factor: 2.340

2.  The relation between neck strength and psychological distress: preliminary evidence from collegiate soccer athletes.

Authors:  Tara Porfido; Nicola L de Souza; Allison M Brown; Jennifer F Buckman; Brian D Fanning; James S Parrott; Carrie Esopenko
Journal:  Concussion       Date:  2021-05-14

3.  Handheld dynamometer reliability to measure knee extension strength in rehabilitation patients-A cross-sectional study.

Authors:  João Pinto-Ramos; Tiago Moreira; Frederico Costa; Helena Tavares; João Cabral; Cristina Costa-Santos; Joana Barroso; Bernardo Sousa-Pinto
Journal:  PLoS One       Date:  2022-05-17       Impact factor: 3.240

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.