Literature DB >> 31090762

Systematic truncating of aptamers to create high-performance graphene oxide (GO)-based aptasensors for the multiplex detection of mycotoxins.

Xinglin Wang1, Xiaoyi Gao1, Jiale He1, Xiaochen Hu1, Yunchao Li1, Xiaohong Li1, Louzhen Fan1, Hua-Zhong Yu2.   

Abstract

Graphene oxide (GO)-based aptasensors are currently one of the most popular sensing platforms for the simple and rapid detection of various targets. Unfortunately, the GO-based aptasensors with long aptamer strands typically show unsatisfactory performance resulting from insignificant structural transformations upon target binding. We report herein the utilization of an aptamer-truncating strategy to combat such a challenge. Taking a pre-selected anti-aflatoxin B1 (AFB1) aptamer (P-AFB1-50) as a trial system, we sequentially remove the extraneous nucleotides within the aptamer by means of circular dichroism (CD) spectroscopy and binding affinity analysis. Particularly, the ratio of the quenching constants between the GO sheets and the truncated aptamers (labelled with fluorophores) in the absence and presence of the target was determined for each of the truncated aptamers to evaluate the optimal sequence. As a result, the truncated aptamer comprising 40 nucleotides was confirmed to show the highest FL output and the best detection limit upon conjugation with GO sheets. More importantly, we demonstrated that this truncating strategy is versatile, i.e., it can be easily extended to other aptamer systems (anti-ochratoxin A (OTA) aptamer, P-OTA-61, as an example) for extraneous nucleotide identification. Impressively, the two optimal truncated aptamers can work together on GO sheets to achieve a simultaneous detection of two different mycotoxins (i.e., AFB1 and OTA) in one single test. Essentially, this research opens a new avenue for the design and testing of aptamer-/GO-based-sensing platforms for rapid, low-cost and multiplex quantification of analytical targets of interest.

Entities:  

Mesh:

Substances:

Year:  2019        PMID: 31090762     DOI: 10.1039/c9an00624a

Source DB:  PubMed          Journal:  Analyst        ISSN: 0003-2654            Impact factor:   4.616


  2 in total

Review 1.  Chemical Modification of Aptamers for Increased Binding Affinity in Diagnostic Applications: Current Status and Future Prospects.

Authors:  Jan P Elskens; Joke M Elskens; Annemieke Madder
Journal:  Int J Mol Sci       Date:  2020-06-25       Impact factor: 5.923

2.  Development of a graphene oxide nanosheet and double-stranded DNA structure based fluorescent "signal off" aptasensor for ochratoxin A detection in malt.

Authors:  Qing Zhang; Linzhi Kang; Pengfei Yue; Linchun Shi; Meng Wang; Lidong Zhou; Haiping Zhao; Weijun Kong
Journal:  Food Chem X       Date:  2022-04-11
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.