Literature DB >> 31088934

Spontaneous Fracture in Intramural and Intra-Abdominal Segments of Peritoneal Dialysis Catheters Presenting as Outflow Failure.

Ashna Wadhawan1, Ramesh Saxena2.   

Abstract

We herewith report 2 unusual cases of spontaneous peritoneal dialysis (PD) catheter fracture in intramural and intra-abdominal segments, respectively, in PD patients with long vintage. There were no associated infections or mechanical trauma. The patients presented with PD catheter outflow failure. Both the patients had their catheter replaced and resumed PD without any further issues. Probable causes and comparison with the reported cases are discussed.
Copyright © 2019 International Society for Peritoneal Dialysis.

Entities:  

Keywords:  Peritoneal dialysis complications; catheter fracture; intra-abdominal rupture; intramural rupture; long duration dialysis; mechanical catheter complications; spontaneous catheter rupture

Mesh:

Year:  2019        PMID: 31088934     DOI: 10.3747/pdi.2018.00200

Source DB:  PubMed          Journal:  Perit Dial Int        ISSN: 0896-8608            Impact factor:   1.756