Is Ductography Still Warranted in the 21st century?

Serine Baydoun1, Pedro Gonzalez2, Gary J Whitman3, Mark Dryden3, Yin Xi4, Basak Dogan5.   

Abstract

OBJECTIVE: To determine the utility of ductography in conjunction with mammography and ultrasound in patients with pathologic nipple discharge, and the incremental role of MRI after triple-modality evaluation.
MATERIALS AND METHODS: We retrospectively reviewed the medical records of patients who had presented with pathologic nipple discharge and had undergone mammography and/or ultrasound and ductography between January 1, 2005, and October 31, 2010. We tested the diagnostic sensitivity, specificity and accuracy of combined triple-modality evaluation as well as of MRI performed in addition to these imaging techniques. We used the gold standard of image-guided biopsies, surgical excision, or long-term clinical and imaging follow-up.
RESULTS: Among 94 study patients, benign papillomas were identified in 42 (44.7%), abscess in one (1%), duct ectasia in four (4.3%), and malignancy (invasive ductal carcinoma or ductal carcinoma in situ) or high-risk lesion (atypical ductal hyperplasia) in 10 (10.6%). Forty-six patients (49%) underwent surgical excision; 89.1% of which had presurgical planning with ductography. In 35 (37.2%) with negative imaging, resolution of nipple discharge was confirmed on median clinical and imaging follow-up of 36 months. Two patients with negative imaging were lost to follow-up. Sensitivity, specificity, PPV, and NPV for accurately demonstrating the etiology of pathologic nipple discharge were 13%, 97%, 89%, and 37% respectively for mammography; 73%, 97%, 98%, and 64% respectively for ultrasound; 76%, 72%, 84%, and 61% respectively for ductography; 86%, 70%, 85%, and 72% respectively for combined ultrasound and ductography; and 75%, 100%, 100% and 67% respectively for DCE-MRI.
CONCLUSION: The combination of mammography, ultrasound and ductography is highly accurate for identifying the etiology of pathologic nipple discharge. DCE-MRI can be used as an alternate to ductography if necessary.
© 2019 Wiley Periodicals, Inc.

Entities:  

Keywords:  DCE-MRI; breast; ductography; pathologic nipple discharge; ultrasound

Mesh:

Substances:

Year:  2019        PMID: 31087408     DOI: 10.1111/tbj.13302

Source DB:  PubMed          Journal:  Breast J        ISSN: 1075-122X            Impact factor:   2.431


  1 in total

1.  The Value of Adding Ductography to Ultrasonography for the Evaluation of Pathologic Nipple Discharge in Women with Negative Mammography.

Authors:  Younjung Choi; Sun Mi Kim; Mijung Jang; Bo La Yun; Eunyoung Kang; Eun-Kyu Kim; So Yeon Park; Bohyoung Kim; Nariya Cho; Woo Kyung Moon
Journal:  Korean J Radiol       Date:  2022-09       Impact factor: 7.109