Riccardo Dal Bello1,2, Paulo Magalhaes Martins1,3, João Graça4, German Hermann5, Thomas Kihm5, Joao Seco1,2. 1. Division of Biomedical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, Heidelberg, 69120, Germany. 2. Department of Physics and Astronomy, Heidelberg University, Neuenheimer Feld 226, Heidelberg, 69120, Germany. 3. Instituto de Biofísica e Engenharia Biomédica, Faculdade de Ciências, Universidade de Lisboa, Campo Grande, Lisboa, 1749-016, Portugal. 4. Electronic Development Laboratory, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, Heidelberg, 69120, Germany. 5. Max-Planck-Institute for Nuclear Physics, P.O. Box 103980, Heidelberg, 69029, Germany.
Abstract
PURPOSE: The presence of range uncertainties hinders the exploitation of the full potential of charged particle therapy. Several range verification techniques have been proposed to mitigate this limitation. Prompt gamma spectroscopy (PGS) is among the most promising solutions for online and in vivo range verification. In this work, we present the experimental results of the detection of prompt gamma radiation, induced by 4 He beams at the Heidelberg Ion-Beam Therapy Center (HIT). The results were obtained, using a spectroscopic unit of which the design has been optimized using Monte Carlo simulations. METHODS: The spectroscopic unit is composed by a primary cerium bromide (CeBr 3 ) crystal surrounded by a secondary bismuth germanate (BGO) crystal for anticoincidence detection (AC). The digitalization of the signals is performed with an advanced FADC/FPGA system. The 4 He beams at clinical energies and intensities are delivered to multiple targets in the experimental cave at the HIT. We analyze the production of prompt gamma on oxygen and carbon targets, as well as high Z materials such as titanium and aluminum. The quantitative analysis includes a systematic comparison of the signal-to-noise ratio (SNR) improvement for the spectral lines when introducing the AC detection. Moreover, the SNR improvement could provide a reduction of the number of events required to draw robust conclusions. We perform a statistic analysis to determine the magnitude of such an effect. RESULTS: We present the energy spectra detected by the primary CeBr 3 and the secondary BGO. The combination of these two detectors leads to an average increase of the signal-to-noise ratio by a factor 2.1, which confirms the Monte Carlo predictions. The spectroscopic unit is capable of detecting efficiently the discrete gamma emission over the full energy spectrum. We identify and analyze 19 independent spectral lines in an energy range spacing from E γ = 0.718 MeV to E γ = 6.13 MeV. Moreover, when introducing the AC detection, the number of events required to determine robustly the intensity of the discrete lines decreases. Finally, the analysis of the low-energy reaction lines determines whether a thin metal insert is introduced in the beam direction. CONCLUSIONS: This work provides the experimental characterization of the spectroscopy unit in development for range verification through PGS at the HIT. Excellent performances have been demonstrated over the full prompt gamma energy spectrum with 4 He beams at clinical energies and intensities.
PURPOSE: The presence of range uncertainties hinders the exploitation of the full potential of charged particle therapy. Several range verification techniques have been proposed to mitigate this limitation. Prompt gamma spectroscopy (PGS) is among the most promising solutions for online and in vivo range verification. In this work, we present the experimental results of the detection of prompt gamma radiation, induced by 4 He beams at the Heidelberg Ion-Beam Therapy Center (HIT). The results were obtained, using a spectroscopic unit of which the design has been optimized using Monte Carlo simulations. METHODS: The spectroscopic unit is composed by a primary cerium bromide (CeBr 3 ) crystal surrounded by a secondary bismuth germanate (BGO) crystal for anticoincidence detection (AC). The digitalization of the signals is performed with an advanced FADC/FPGA system. The 4 He beams at clinical energies and intensities are delivered to multiple targets in the experimental cave at the HIT. We analyze the production of prompt gamma on oxygen and carbon targets, as well as high Z materials such as titanium and aluminum. The quantitative analysis includes a systematic comparison of the signal-to-noise ratio (SNR) improvement for the spectral lines when introducing the AC detection. Moreover, the SNR improvement could provide a reduction of the number of events required to draw robust conclusions. We perform a statistic analysis to determine the magnitude of such an effect. RESULTS: We present the energy spectra detected by the primary CeBr 3 and the secondary BGO. The combination of these two detectors leads to an average increase of the signal-to-noise ratio by a factor 2.1, which confirms the Monte Carlo predictions. The spectroscopic unit is capable of detecting efficiently the discrete gamma emission over the full energy spectrum. We identify and analyze 19 independent spectral lines in an energy range spacing from E γ = 0.718 MeV to E γ = 6.13 MeV. Moreover, when introducing the AC detection, the number of events required to determine robustly the intensity of the discrete lines decreases. Finally, the analysis of the low-energy reaction lines determines whether a thin metal insert is introduced in the beam direction. CONCLUSIONS: This work provides the experimental characterization of the spectroscopy unit in development for range verification through PGS at the HIT. Excellent performances have been demonstrated over the full prompt gamma energy spectrum with 4 He beams at clinical energies and intensities.
Authors: Paulo Magalhaes Martins; Riccardo Dal Bello; Benjamin Ackermann; Stephan Brons; German Hermann; Thomas Kihm; Joao Seco Journal: Sci Rep Date: 2020-04-24 Impact factor: 4.379
Authors: Hugo Freitas; Paulo Magalhaes Martins; Thomas Tessonnier; Benjamin Ackermann; Stephan Brons; Joao Seco Journal: Sci Data Date: 2021-09-29 Impact factor: 6.444
Authors: Paulo Magalhaes Martins; Hugo Freitas; Thomas Tessonnier; Benjamin Ackermann; Stephan Brons; Joao Seco Journal: Sci Rep Date: 2021-07-28 Impact factor: 4.379