Literature DB >> 31087268

Upper reference limits of transient ischemic dilation ratio for different protocols on new-generation cadmium zinc telluride cameras: A report from REFINE SPECT registry.

Lien-Hsin Hu1,2, Tali Sharir3,4, Robert J H Miller1, Andrew J Einstein5, Mathews B Fish6, Terrence D Ruddy7, Sharmila Dorbala8, Marcelo Di Carli8, Philipp A Kaufmann9, Albert J Sinusas10, Edward J Miller10, Timothy M Bateman11, Julian Betancur1, Guido Germano1, Joanna X Liang1, Frederic Commandeur1, Peyman N Azadani1, Heidi Gransar1, Yuka Otaki1, Balaji K Tamarappoo1, Damini Dey1, Daniel S Berman1, Piotr J Slomka12.   

Abstract

BACKGROUND: Upper reference limits for transient ischemic dilation (TID) have not been rigorously established for cadmium-zinc-telluride (CZT) camera systems. We aimed to derive TID limits for common myocardial perfusion imaging protocols utilizing a large, multicenter registry (REFINE SPECT).
METHODS: One thousand six hundred and seventy-two patients with low likelihood of coronary artery disease with normal perfusion findings were identified. Images were processed with Quantitative Perfusion SPECT software (Cedars-Sinai Medical Center, Los Angeles, CA). Non-attenuation-corrected, camera-, radiotracer-, and stress protocol-specific TID limits in supine position were derived from 97.5th percentile and mean + 2 standard deviations (SD). Reference limits were compared for different solid-state cameras (D-SPECT vs. Discovery), radiotracers (technetium-99m-sestamibi vs. tetrofosmin), different types of stress (exercise vs. four different vasodilator-based protocols), and different vasodilator-based protocols.
RESULTS: TID measurements did not follow Gaussian distribution in six out of eight subgroups. TID limits ranged from 1.18 to 1.52 (97.5th percentile) and 1.18 to 1.39 (mean + 2SD). No difference was noted between D-SPECT and Discovery cameras (P = 0.71) while differences between exercise and vasodilator-based protocols (adenosine, regadenoson, or regadenoson-walk) were noted (all P < 0.05).
CONCLUSIONS: We used a multicenter registry to establish camera-, radiotracer-, and protocol-specific upper reference limits of TID for supine position on CZT camera systems. Reference limits did not differ between D-SPECT and Discovery camera.

Entities:  

Keywords:  Coronary artery disease; image analysis; myocardial perfusion imaging; perfusion agents; single-photon emission computed tomography; vasodilators

Year:  2019        PMID: 31087268      PMCID: PMC6851400          DOI: 10.1007/s12350-019-01730-y

Source DB:  PubMed          Journal:  J Nucl Cardiol        ISSN: 1071-3581            Impact factor:   5.952


  33 in total

1.  Left ventricular dilatation and pulmonary thallium uptake after single-photon emission computer tomography using thallium-201 during adenosine-induced coronary hyperemia.

Authors:  A S Iskandrian; J Heo; T Nguyen; E Lyons; E Paugh
Journal:  Am J Cardiol       Date:  1990-10-01       Impact factor: 2.778

2.  Integration of automatically measured transient ischemic dilation ratio into interpretation of adenosine stress myocardial perfusion SPECT for detection of severe and extensive CAD.

Authors:  Aiden Abidov; Jeroen J Bax; Sean W Hayes; Ishac Cohen; Hidetaka Nishina; Shunichi Yoda; Xingping Kang; Fatma Aboul-Enein; James Gerlach; John D Friedman; Rory Hachamovitch; Guido Germano; Daniel S Berman
Journal:  J Nucl Med       Date:  2004-12       Impact factor: 10.057

3.  The increasing role of quantification in clinical nuclear cardiology: the Emory approach.

Authors:  Ernest V Garcia; Tracy L Faber; C David Cooke; Russell D Folks; Ji Chen; Cesar Santana
Journal:  J Nucl Cardiol       Date:  2007-07       Impact factor: 5.952

Review 4.  Advances in technical aspects of myocardial perfusion SPECT imaging.

Authors:  Piotr J Slomka; James A Patton; Daniel S Berman; Guido Germano
Journal:  J Nucl Cardiol       Date:  2009-02-26       Impact factor: 5.952

5.  The prognostic value of transient ischemic dilatation with otherwise normal SPECT myocardial perfusion imaging: a cautionary note in patients with diabetes and coronary artery disease.

Authors:  Rami Doukky; Nathan Frogge; Yohannes A Bayissa; Gautam Balakrishnan; Jacob M Skelton; Kara Confer; Kalindi Parikh; Russell F Kelly
Journal:  J Nucl Cardiol       Date:  2013-08-09       Impact factor: 5.952

6.  The significance of automatically measured transient ischemic dilation in identifying severe and extensive coronary artery disease in regadenoson, single-isotope technetium-99m myocardial perfusion SPECT.

Authors:  Yasmeen Golzar; Adebayo Olusanya; Nadith Pe; Sumeet G Dua; Jaafer Golzar; Claudia Gidea; Rami Doukky
Journal:  J Nucl Cardiol       Date:  2015-04-01       Impact factor: 5.952

7.  Normal limits for transient ischemic dilation with 99mTc myocardial perfusion SPECT protocols.

Authors:  Piotr J Slomka; Daniel S Berman; Guido Germano
Journal:  J Nucl Cardiol       Date:  2016-06-28       Impact factor: 5.952

8.  Analysis of probability as an aid in the clinical diagnosis of coronary-artery disease.

Authors:  G A Diamond; J S Forrester
Journal:  N Engl J Med       Date:  1979-06-14       Impact factor: 91.245

9.  Dilatation of left ventricular cavity on stress thallium scan as an indicator of ischemic disease.

Authors:  J Stolzenberg
Journal:  Clin Nucl Med       Date:  1980-07       Impact factor: 7.794

10.  Adopting new gamma cameras and reconstruction algorithms: Do we need to re-establish normal reference values?

Authors:  Timothy L Miao; Vinay Kansal; R Glenn Wells; Iftikhar Ali; Terrence D Ruddy; Benjamin J W Chow
Journal:  J Nucl Cardiol       Date:  2015-08-25       Impact factor: 5.952

View more
  8 in total

Review 1.  Quantitative Clinical Nuclear Cardiology, Part 1: Established Applications.

Authors:  Ernest V Garcia; Piotr Slomka; Jonathan B Moody; Guido Germano; Edward P Ficaro
Journal:  J Nucl Med       Date:  2019-11       Impact factor: 10.057

2.  Transient ischaemic dilation and post-stress wall motion abnormality increase risk in patients with less than moderate ischaemia: analysis of the REFINE SPECT registry.

Authors:  Robert J H Miller; Lien-Hsin Hu; Heidi Gransar; Julian Betancur; Evann Eisenberg; Yuka Otaki; Tali Sharir; Mathews B Fish; Terrence D Ruddy; Sharmila Dorbala; Marcelo Di Carli; Andrew J Einstein; Philipp A Kaufmann; Albert J Sinusas; Edward J Miller; Timothy Bateman; Guido Germano; Balaji K Tamarappoo; Damini Dey; Daniel S Berman; Piotr J Slomka
Journal:  Eur Heart J Cardiovasc Imaging       Date:  2020-05-01       Impact factor: 6.875

3.  Mitigating bias in deep learning for diagnosis of coronary artery disease from myocardial perfusion SPECT images.

Authors:  Robert J H Miller; Ananya Singh; Yuka Otaki; Balaji K Tamarappoo; Paul Kavanagh; Tejas Parekh; Lien-Hsin Hu; Heidi Gransar; Tali Sharir; Andrew J Einstein; Mathews B Fish; Terrence D Ruddy; Philipp A Kaufmann; Albert J Sinusas; Edward J Miller; Timothy M Bateman; Sharmila Dorbala; Marcelo F Di Carli; Joanna X Liang; Damini Dey; Daniel S Berman; Piotr J Slomka
Journal:  Eur J Nucl Med Mol Imaging       Date:  2022-10-04       Impact factor: 10.057

4.  External validation of the CRAX2MACE model.

Authors:  Waseem Hijazi; Willam Leslie; Neil Filipchuk; Ryan Choo; Stephen Wilton; Matthew James; Piotr J Slomka; Robert J H Miller
Journal:  J Nucl Cardiol       Date:  2022-04-13       Impact factor: 3.872

Review 5.  Quantitative Clinical Nuclear Cardiology, Part 1: Established Applications.

Authors:  Ernest V Garcia; Piotr Slomka; Jonathan B Moody; Guido Germano; Edward P Ficaro
Journal:  J Nucl Cardiol       Date:  2019-10-25       Impact factor: 5.952

6.  Quantitation of Poststress Change in Ventricular Morphology Improves Risk Stratification.

Authors:  Robert J H Miller; Tali Sharir; Yuka Otaki; Heidi Gransar; Joanna X Liang; Andrew J Einstein; Mathews B Fish; Terrence D Ruddy; Philipp A Kaufmann; Albert J Sinusas; Edward J Miller; Timothy M Bateman; Sharmila Dorbala; Marcelo Di Carli; Balaji K Tamarappoo; Damini Dey; Daniel S Berman; Piotr J Slomka
Journal:  J Nucl Med       Date:  2021-03-12       Impact factor: 11.082

7.  Automated quantitative analysis of CZT SPECT stratifies cardiovascular risk in the obese population: Analysis of the REFINE SPECT registry.

Authors:  Eyal Klein; Robert J H Miller; Tali Sharir; Andrew J Einstein; Mathews B Fish; Terrence D Ruddy; Philipp A Kaufmann; Albert J Sinusas; Edward J Miller; Timothy M Bateman; Sharmila Dorbala; Marcelo Di Carli; Yuka Otaki; Heidi Gransar; Joanna X Liang; Damini Dey; Daniel S Berman; Piotr J Slomka
Journal:  J Nucl Cardiol       Date:  2020-09-14       Impact factor: 5.952

8.  Clinical quantitative cardiac imaging for the assessment of myocardial ischaemia.

Authors:  Marc Dewey; Maria Siebes; Marc Kachelrieß; Klaus F Kofoed; Pál Maurovich-Horvat; Konstantin Nikolaou; Wenjia Bai; Andreas Kofler; Robert Manka; Sebastian Kozerke; Amedeo Chiribiri; Tobias Schaeffter; Florian Michallek; Frank Bengel; Stephan Nekolla; Paul Knaapen; Mark Lubberink; Roxy Senior; Meng-Xing Tang; Jan J Piek; Tim van de Hoef; Johannes Martens; Laura Schreiber
Journal:  Nat Rev Cardiol       Date:  2020-02-24       Impact factor: 32.419

  8 in total