Literature DB >> 31085030

Non-linear Acoustic Emissions from Therapeutically Driven Contrast Agent Microbubbles.

Jae Hee Song1, Alexandru Moldovan2, Paul Prentice3.   

Abstract

Non-linear emissions from microbubbles introduced to the vasculature for exposure to focused ultrasound are routinely monitored for assessment of therapy and avoidance of irreversible tissue damage. Yet the bubble-based mechanistic source for these emissions, under subresonant driving at typical therapeutic pressure amplitudes, may not be well understood. In the study described here, dual-perspective high-speed imaging at 210,000 frames per second (fps), and shadowgraphically at 10 Mfps, was used to observe cavitation from microbubbles flowing through a 500-µm polycarbonate capillary exposed to focused ultrasound of 692 kHz at therapeutically relevant pressure amplitudes. The acoustic emissions were simultaneously collected via a broadband calibrated needle hydrophone system. The observations indicate that periodic bubble-collapse shock waves can dominate the non-linear acoustic emissions, including subharmonics at higher driving amplitudes. Contributions to broadband emissions through variance in shock wave amplitude and emission timings are also identified. Possible implications for in vivo microbubble cavitation detection, mechanisms of therapy and the conventional classification of cavitation activity as stable or inertial are discussed.
Copyright © 2019 The Authors. Published by Elsevier Inc. All rights reserved.

Keywords:  Acoustic emissions; Bubble collapse; Cavitation; Focused ultrasound; Microbubble; Shock wave

Mesh:

Substances:

Year:  2019        PMID: 31085030     DOI: 10.1016/j.ultrasmedbio.2019.04.005

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  5 in total

1.  Influence of Nanobubble Size Distribution on Ultrasound-Mediated Plasmid DNA and Messenger RNA Gene Delivery.

Authors:  Hiroshi Kida; Loreto B Feril; Yutaka Irie; Hitomi Endo; Keiji Itaka; Katsuro Tachibana
Journal:  Front Pharmacol       Date:  2022-06-01       Impact factor: 5.988

2.  Contrast Agent Microbubble Jetting during Initial Interaction with 200-kHz Focused Ultrasound.

Authors:  Sarah Cleve; Claude Inserra; Paul Prentice
Journal:  Ultrasound Med Biol       Date:  2019-08-30       Impact factor: 2.998

3.  Nanobubble Mediated Gene Delivery in Conjunction With a Hand-Held Ultrasound Scanner.

Authors:  Hiroshi Kida; Koyo Nishimura; Koki Ogawa; Akiko Watanabe; Loreto B Feril; Yutaka Irie; Hitomi Endo; Shigeru Kawakami; Katsuro Tachibana
Journal:  Front Pharmacol       Date:  2020-04-01       Impact factor: 5.810

4.  Claudin-5 binder enhances focused ultrasound-mediated opening in an in vitro blood-brain barrier model.

Authors:  Liyu Chen; Ratneswary Sutharsan; Jonathan Lf Lee; Esteban Cruz; Blaise Asnicar; Tishila Palliyaguru; Joanna M Wasielewska; Arnaud Gaudin; Jae Song; Gerhard Leinenga; Jürgen Götz
Journal:  Theranostics       Date:  2022-01-31       Impact factor: 11.556

5.  Characterising the cavitation activity generated by an ultrasonic horn at varying tip-vibration amplitudes.

Authors:  Lukman Yusuf; Mark D Symes; Paul Prentice
Journal:  Ultrason Sonochem       Date:  2020-08-06       Impact factor: 7.491

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.