Literature DB >> 31084375

Will Stone Density Stop Being a Key Factor in Endourology? The Impact of Stone Density on Laser Time Using Lumenis Laser p120w and Standard 20 W Laser: A Comparative Study.

Matan Mekayten1, Amitay Lorber1, Ioannis Katafigiotis2, Stavros Sfoungaristos3, Ioannis Leotsakos1, Eliyahu Meir Heifetz4, Vladimir Yutkin1, Ofer Nathan Gofrit1, Mordechai Duvdevani1.   

Abstract

Introduction and
Objectives: Ureteroscopy is the gold standard for most urinary tract calculi. Our institute recently incorporated a powerful 120 W holmium laser machine integrating innovative technology (Lumenis® MOSES PulseTM120H Holmium:YAG laser; Lumenis Ltd.). In this retrospective comparative study, we evaluated the influence of stone density on laser dusting time in a high-power 120 W laser machine vs a standard 20 W machine (Dornier Medilas® H20 Holmium:YAG laser; Dornier Ltd.)
Methods: We conducted a retrospective review of medical records of patients who underwent ureteroscopy during the years 2013-2018 for a solitary stone. Stone and clinical characteristics, among other parameters, have been evaluated, including the total laser time until complete stone dusting.
Results: Among 631 eligible patients, 462 were treated with a 20 W standard laser and 169 patients with a p120w laser machine. Overall laser time was less than half with p120w laser vs d20w (195 seconds vs 397.14 seconds, p-value <0.001). Multivariate regression demonstrated 234.91 seconds shorter laser time with a p120w laser while controlling confounders such as stone volume, hydronephrosis, and location (p value <0.0001). This pattern was demonstrated in all stone densities. The association between laser dusting time per stone volume and stone density demonstrated relatively constant laser time when using p120w laser, even for hard stones. When the standard 20 W laser was used, laser time was longer in each stone density. Moreover, a stone density of 1164 HU and more demonstrated an upward shift of laser time to stone density curve in standard d20w laser group only. Conclusions: Time to complete stone dusting using p120w laser is extremely shorter, approximately half, comparing with the standard 20 W laser. This pattern is robust and even exponential when evaluating laser time per stone density, especially in hard stones. A new horizon of powerful innovative laser technology will enable to improve endourology practice and patients' care.

Entities:  

Keywords:  laser; lumenis; nephrolithiasis; percutaneous nephrolithotomy; ureteroscopy; urolithiasis

Mesh:

Year:  2019        PMID: 31084375     DOI: 10.1089/end.2019.0181

Source DB:  PubMed          Journal:  J Endourol        ISSN: 0892-7790            Impact factor:   2.942


  7 in total

1.  Basic and advanced technological evolution of laser lithotripsy over the past decade: An educational review by the European Society of Urotechnology Section of the European Association of Urology.

Authors:  Lazaros Tzelves; Bhaskar Somani; Marinos Berdempes; Titos Markopoulos; Andreas Skolarikos
Journal:  Turk J Urol       Date:  2021-05

2.  Role of low- versus high-power laser in the treatment of lower pole stones: prospective non-randomized outcomes from a university teaching hospital.

Authors:  Amelia Pietropaolo; Mriganka Mani; Thomas Hughes; Bhaskar K Somani
Journal:  Ther Adv Urol       Date:  2022-05-26

Review 3.  A Practical Guide for Intra-Renal Temperature and Pressure Management during Rirs: What Is the Evidence Telling Us.

Authors:  Felipe Pauchard; Eugenio Ventimiglia; Mariela Corrales; Olivier Traxer
Journal:  J Clin Med       Date:  2022-06-15       Impact factor: 4.964

Review 4.  New Generation Pulse Modulation in Holmium:YAG Lasers: A Systematic Review of the Literature and Meta-Analysis.

Authors:  Antoni Sánchez-Puy; Alejandra Bravo-Balado; Pietro Diana; Michael Baboudjian; Alberto Piana; Irene Girón; Andrés K Kanashiro; Oriol Angerri; Pablo Contreras; Brian H Eisner; Josep Balañà; Francisco M Sánchez-Martín; Félix Millán; Joan Palou; Esteban Emiliani
Journal:  J Clin Med       Date:  2022-06-04       Impact factor: 4.964

5.  How do we assess the efficacy of Ho:YAG low-power laser lithotripsy for the treatment of upper tract urinary stones? Introducing the Joules/mm3 and laser activity concepts.

Authors:  Eugenio Ventimiglia; Felipe Pauchard; Antonio Rebello Horta Gorgen; Frédéric Panthier; Steeve Doizi; Olivier Traxer
Journal:  World J Urol       Date:  2020-05-27       Impact factor: 4.226

6.  The Effects of Scanning Speed and Standoff Distance of the Fiber on Dusting Efficiency during Short Pulse Holmium: YAG Laser Lithotripsy.

Authors:  Junqin Chen; Daiwei Li; Wenjun Yu; Zhiteng Ma; Chenhang Li; Gaoming Xiang; Yuan Wu; Junjie Yao; Pei Zhong
Journal:  J Clin Med       Date:  2022-08-28       Impact factor: 4.964

Review 7.  Moses and Moses 2.0 for Laser Lithotripsy: Expectations vs. Reality.

Authors:  Mariela Corrales; Alba Sierra; Olivier Traxer
Journal:  J Clin Med       Date:  2022-08-18       Impact factor: 4.964

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.