Literature DB >> 31080936

Real-time computerized video enhancement for minimally invasive fetoscopic surgery.

Praneeth Sadda1, John Onofrey2,3, Metehan Imamoglu1,4,5, Xenophon Papademetris1,2,3, Bilal Qarni6, Mert Ozan Bahtiyar1,4,5.   

Abstract

BACKGROUND: The only definitive treatment for twin-to-twin transfusion syndrome is minimally invasive fetoscopic surgery for the selective coagulation of placental blood vessels. Fetoscopic surgery is a technically challenging operation, mainly due to the poor visibility conditions in the uterine environment. We present the design of an algorithm for the computerized enhancement of fetoscopic video and show that the enhanced video increases the ability of human users to identify blood vessels within fetoscopic video rapidly and accurately.
METHODS: A computer algorithm for the enhancement of fetoscopic video frames was created. First, optical fiber artifacts were removed via a modification of unsharp masking. Second, image contrast was increased via Contrast Limited Adaptive Histogram Equalization (CLAHE). Third, the effect of contrast enhancements on stationary features was removed by normalizing to a windowed mean of the video frames. Fourth, color information was reincorporated by combining the mean-normalized result with the unnormalized contrast enhanced image using the soft light blending algorithm. Medical trainees (n = 16) were recruited into a study to validate the algorithm. Subjects were shown enhanced or unenhanced fetoscopic video frames on a screen and were asked to identify whether a randomly placed marker fell on a blood vessel or on background. The accuracy of their responses was recorded.
RESULTS: On the subset of images where subjects had the lowest mean accuracy in identifying the placement of the marker, subjects performed better when viewing video frames enhanced by the computer (accuracy 74.27%; SE 0.97) than when viewing unenhanced video frames (accuracy 63.78%; SE 2.79). This result was statistically significant (p < 0.01).
CONCLUSION: Real-time computerized enhancement of fetoscopic video has the potential to ease the readability of video in poor lighting conditions, thus providing a benefit to the surgeon intraoperatively.

Entities:  

Year:  2018        PMID: 31080936      PMCID: PMC6508886          DOI: 10.1016/j.lers.2018.06.001

Source DB:  PubMed          Journal:  Laparosc Endosc Robot Surg        ISSN: 2468-9009


  12 in total

1.  Sharpening the image.

Authors:  George A Taylor
Journal:  AJR Am J Roentgenol       Date:  2003-07       Impact factor: 3.959

2.  A generalized unsharp masking algorithm.

Authors:  Guang Deng
Journal:  IEEE Trans Image Process       Date:  2010-11-15       Impact factor: 10.856

Review 3.  The North American Fetal Therapy Network Consensus Statement: Management of Complicated Monochorionic Gestations.

Authors:  Stephen P Emery; Mert O Bahtiyar; Kenneth J Moise
Journal:  Obstet Gynecol       Date:  2015-09       Impact factor: 7.661

4.  An evaluation of the effectiveness of adaptive histogram equalization for contrast enhancement.

Authors:  J B Zimmerman; S M Pizer; E V Staab; J R Perry; W McCartney; B C Brenton
Journal:  IEEE Trans Med Imaging       Date:  1988       Impact factor: 10.048

5.  Nonlinear unsharp masking for mammogram enhancement.

Authors:  Karen Panetta; Yicong Zhou; Sos Agaian; Hongwei Jia
Journal:  IEEE Trans Inf Technol Biomed       Date:  2011-08-12

Review 6.  Deep learning.

Authors:  Yann LeCun; Yoshua Bengio; Geoffrey Hinton
Journal:  Nature       Date:  2015-05-28       Impact factor: 49.962

7.  The North American Fetal Therapy Network consensus statement: prenatal surveillance of uncomplicated monochorionic gestations.

Authors:  Mert Ozan Bahtiyar; Stephen P Emery; Jodi S Dashe; Louise E Wilkins-Haug; Anthony Johnson; Bettina W Paek; Anita J Moon-Grady; Daniel W Skupski; Barbara M O'Brien; Christopher R Harman; Lynn L Simpson
Journal:  Obstet Gynecol       Date:  2015-01       Impact factor: 7.661

8.  Iterative l(1)-min algorithm for fixed pattern noise removal in fiber-bundle-based endoscopic imaging.

Authors:  Xuan Liu; Lijun Zhang; Mitchell Kirby; Richard Becker; Shaohai Qi; Feng Zhao
Journal:  J Opt Soc Am A Opt Image Sci Vis       Date:  2016-04-01       Impact factor: 2.129

9.  Pixelation effect removal from fiber bundle probe based optical coherence tomography imaging.

Authors:  Jae-Ho Han; Junghoon Lee; Jin U Kang
Journal:  Opt Express       Date:  2010-03-29       Impact factor: 3.894

Review 10.  Computer-assisted surgical planning and intraoperative guidance in fetal surgery: a systematic review.

Authors:  Rosalind Pratt; Jan Deprest; Tom Vercauteren; Sebastien Ourselin; Anna L David
Journal:  Prenat Diagn       Date:  2015-09-16       Impact factor: 3.050

View more
  1 in total

Review 1.  Computer-assisted fetal laser surgery in the treatment of twin-to-twin transfusion syndrome: Recent trends and prospects.

Authors:  Anouk Marlon van der Schot; Esther Sikkel; Marc Erich August Spaanderman; Frank Patrick Hector Achilles Vandenbussche
Journal:  Prenat Diagn       Date:  2022-08-29       Impact factor: 3.242

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.