Literature DB >> 31077272

One-Stage Augmentation Mastopexy: A Retrospective Ten-Year Review of 2183 Consecutive Procedures.

Charles A Messa2, Charles A Messa2.   

Abstract

BACKGROUND: Although numerous studies supporting breast augmentation with simultaneous mastopexy have been reported, concerns persist among surgeons regarding the safety of this procedure.
OBJECTIVES: The authors sought to evaluate the safety and effectiveness of 1-stage augmentation mastopexy by analyzing long-term complication and reoperation rates.
METHODS: The authors conducted a retrospective review of 1131 patients who underwent 2183 consecutive 1-stage augmentation mastopexy procedures from January 2006 to August 2016. Patient demographics, operative technique, and implant specifications were measured and analyzed with surgical outcomes. Long-term complication and reoperation rates were noted.
RESULTS: Over a mean follow-up period of 43 months (range, 4-121 months), the overall complication rate was 15.3% (n = 173) with a reoperation rate of 14.7% (n = 166). Tissue-related complications included hypertrophic scarring in 2.5% (n = 28) and recurrent ptosis in 2.1% (n = 24). The most common implant-related complication was capsular contracture (Baker III or IV) in 2.8% (n = 32). The most common indications for reoperation were recurrent ptosis in 3.5% (n = 40 patients) and desire to change implant size in 3.2% (n = 36 patients). Circumareolar augmentation mastopexy technique was associated with a higher reoperation rate of 25.7% (P < 0.0005). Patients with a history of smoking had a higher incidence of complications (26.1%) and reoperations (22.5%; P < 0.0005). There were no cases of significant skin flap necrosis (>2 cm).
CONCLUSIONS: One-stage augmentation mastopexy can be safely performed with a reoperation rate that is significantly lower than when the procedure is staged. The effectiveness of this procedure is defined by a low complication rate and a reduced number of operations for the patient.
© 2019 The American Society for Aesthetic Plastic Surgery, Inc. Reprints and permission: journals.permissions@oup.com.

Entities:  

Mesh:

Year:  2019        PMID: 31077272     DOI: 10.1093/asj/sjz143

Source DB:  PubMed          Journal:  Aesthet Surg J        ISSN: 1090-820X            Impact factor:   4.283


  2 in total

1.  A Comparison of 28 Published Augmentation/Mastopexy Techniques Using Photographic Measurements.

Authors:  Eric Swanson
Journal:  Plast Reconstr Surg Glob Open       Date:  2020-09-21

2.  A Modified Superior Pedicle Mastopexy Technique with an Inferolateral-Based Auto Augmentation Flap.

Authors:  Yue Liu; Jie Luan
Journal:  Aesthetic Plast Surg       Date:  2021-07-01       Impact factor: 2.326

  2 in total