Frictional characterization of injectable hyaluronic acids is more predictive of clinical outcomes than traditional rheological or viscoelastic characterization.

Edward D Bonnevie1, Devis Galesso2, Cynthia Secchieri2, Lawrence J Bonassar1,3.   

Abstract

Hyaluronic acid injections have been a mainstay of arthritis treatment for decades. However, much controversy remains about their clinical efficacy and their potential mechanism of action. This approach to arthritis therapy is often called viscosupplementation, a term which is rooted in the elevated viscosity of the injected solutions. This terminology also suggests a mechanical pathway of action and further implies that their efficacy is dependent on viscosity. Notably, previous studies of the relationship between viscous properties of hyaluronic acid solutions and their clinical efficacy have not been definitive. Recently we developed an experimental and analytical framework for studying cartilage lubrication that captures the Stribeck-like behavior of cartilage in an elastoviscous transition curve. Here we apply this framework to study the lubricating behavior of six hyaluronan products currently used for injectable arthritis therapy in the US. Despite the fact that the source and chemical modifications endow these products with a range of lubricating properties, we show that the lubricating effect of all of these materials can be described by this Stribeck-like elastoviscous transition. Fitting this data to the elastoviscous transition model enables the calculation of effective lubricating viscosities for each material, which differ substantially from the viscosities measured using standard rheometry. Further we show that while data from standard rheometry are poor predictors of clinical performance of these materials, measurements of friction coefficient and effective lubricating viscosity correlate well (R2 = 0.77; p < 0.005) with assessments of improved clinical function reported previously. This approach offers both a novel method that can be used to evaluate potential clinical efficacy of hyaluronic acid formulations and provide new insight on their mode of action.

Entities:  

Mesh:

Substances:

Year:  2019        PMID: 31075142      PMCID: PMC6510437          DOI: 10.1371/journal.pone.0216702

Source DB:  PubMed          Journal:  PLoS One        ISSN: 1932-6203            Impact factor:   3.240


Introduction

Intra-articular injections of hyaluronic acid has been a mainstay of arthritis treatment since initial trials of such therapies more than 30 years ago [1,2]. This course of therapy was termed “viscosupplementation” based on the restoration of viscosity observed after delivery to pathologic synovial fluid [3]. Significant controversy persists around the clinical efficacy and proposed underlying mechanisms of these therapies. Recently, conflicting consensus statements were released from multiple clinical societies based on meta-analyses of clinical studies, which show either no statistical effect of hyaluronic acid injections over placebo [4], or beneficial effects at reducing pain and restoring function in cases of mild to moderate osteoarthritis [5,6], particularly in patients with knee OA who have not had an adequate response to non-pharmacologic modalities and full-dose acetaminophen [7-9]. Despite this controversy, use of such products is widespread, and annual sales are expected to surpass $2.6 billion in the near future [10]. This controversy is rooted in the fact that it is difficult to prove clinical efficacy versus placebo and that there is no consensus concerning the mechanism of action. Many studies report that hyaluronic acid has a protective effect on cartilage explants and chondrocytes through multiple biological mechanisms. As a critical component of the cartilage extracellular matrix, hyaluronic acid interacts with chondrocytes through the CD44 receptor [11]. This binding is thought to be both anabolic and anti-catabolic, inhibiting expression and activity of inflammatory cytokines [12] and degradative proteinases in vitro [13], and reducing matrix damage [14], fibrosis [15], and expression of inflammatory markers in vivo [16]. Although such potential biological mechanisms exist, the FDA classifies hyaluronic acid injections as class III medical devices, implying that a primary mode of action is mechanical. Indeed, the lubricating role of hyaluronic acid in synovial fluid has been known for decades [17]. Addition of hyaluronic acid is known to lower friction coefficients of whole joints [18,19] and in ex vivo studies of cartilage-on-cartilage [20] and cartilage-on-glass [21] interfaces. Although injecting hyaluronic acid is commonly referred to as ‘viscosupplementation’, there has been relatively little direct investigation of the extent to which the viscosity of hyaluronic acid governs its lubricating ability and clinical efficacy. Many studies, focusing on either lubricating properties or in vivo efficacy, have compared hyaluronic acid solutions based on molecular weight, which is typically related to intrinsic viscosity via a power law relationship (i.e., the Mark-Houwink equation). However, inferring the effect of viscosity from such studies can be challenging, as the Mark-Houwink coefficients for hyaluronic acid solutions vary with molecular weight [22]. Further, the relationship between molecular weight and intrinsic viscosity can change when the molecule is modified or partially crosslinked. While molecular weight correlates with improved lubrication in experiments using isolated cartilage tissue [20,23] and whole joints [18], the relationship between molecular weight and clinical outcomes is less clear. Several studies report that high molecular weight formulations improve outcomes, both in preclinical studies [24-26] and in human trials [27]. In contrast, several studies report no clinical benefit of increasing molecular weight [28-34] or crosslinking [35], while others suggest that low molecular weight formulations may be superior [36] due to their ability to more effectively penetrate the cartilage matrix [37]. Additionally, the relationship between rheological and viscoelastic properties and clinical outcomes is complicated due to the complex mechanical properties of HA formulations. Although it is well understood that these solutions are described by non-Newtonian, shear thinning behavior [22], their mechanical properties are not be fully captured by conventional rheology. Recent evidence suggests that standard rheologic analyses are confounded due to the interfacial viscosity [38], and consequently, the in vivo situation is even further confounded as HA is known to interact with the proteins at the articular surface [21,39,40]. Because of these factors, the relationship between HA mechanical properties and clinical efficacy has not been well established. The lack of clarity from these above studies suggests that a new framework is needed to understand the action of hyaluronic acid and to develop tools to predict both lubricating ability and clinical outcomes. Several studies have attempted to understand cartilage tissue and joint lubrication in the context of classic lubrication framework using a Stribeck curve [19,41,42], where distinct lubrication modes are mapped as a function of sliding speed, normal load, sample geometry, and lubricant viscosity. Classically, for hard permeable materials in specific geometries, the curve maps a frictional transition from boundary mode marked by solid-solid contact, to partial separation of surfaces by pressurized fluid, to full separation by a fluid film, which results in extremely low friction. Recently, it was shown that soft, permeable materials [43], including articular cartilage [21] undergo a similar “elastoviscous transition” in lubrication behavior. Using this framework, the transition of cartilage tissue through different lubrication modes was shown to be predicted by the viscosity of hyaluronic acid solutions. The goals of the current study were to evaluate the lubricating properties of 6 hyaluronan formulations that are currently used in the US and to determine the extent to which their rheological and viscoelastic properties measured by traditional means, and frictional properties are correlated with their clinical function. Here, we show that commercial formulations of hyaluronic acid produce speed-dependent friction of cartilage, but these friction coefficients are not well described by standard rheological techniques. Further, using a Stribeck-like framework enables the calculation of an effective lubricating viscosity for each formulation that is distinct from the measured dynamic viscosity. Finally, we show that the effective lubricating viscosity and friction coefficient measured in vitro correlate with changes in clinical outcome data aggregated from previous clinical trials.

Results

Clinically approved HA formulations exhibit a wide range of rheological behavior

To test the hypothesis that the clinical efficacy of HA injections is related to its mechanical properties, we tested six clinically-approved HA formulations (Synvisc, Monovisc, Hyalgan, Euflexxa, Supartz, and Hymovis) using a commercial rheometer. In brief, we conducted experiments in which shear rate was increased from 0.1 to 100 s-1 using a cone-plate rheometer configuration. As expected, we found shear thinning behavior in each of the formulations, but viscosities varied by orders of magnitude between the products (). To more fully characterize these results, we fit this rheological data to a Carreau-Yasuda model given by the equation: Where, η is dynamic viscosity, η is the dynamic viscosity at infinite shear rate, η is the dynamic viscosity at zero shear rate, is shear rate, and λ, n, and a are fitting parameters (). Data from all commercial formulations were described well by the Carreau-Yasuda model, with coefficients of variation <10% for all fits (). Additionally, we characterized the viscoelastic properties of each of these products in oscillatory shear (3% strain from 0.1 to 100 rad/sec). Overall, we found that the rheological properties of all of these HA formulations varied by orders of magnitude. Specifically, the storage and loss moduli ranged from under 0.1 Pa to over 100 Pa and under 1 Pa to 100 Pa, respectively. Additionally, there was a range of phase angles observed at low shear rates (0.1 rad/s) that ranged from 28° to 83° indicating that the HA formulations exhibit a range of elastic versus viscous behavior ().

Rheology of clinical HA formulations.

(A) Flow sweep experiments revealed shear thinning behavior of all HA formulations, but orders of magnitude variations in dynamic viscosity were evident. (B,C) Storage and loss moduli of the same HA formulations as a function of angular frequency.

Carreau-Yasuda model parameters for 6 clinically approved HA viscosupplements.

Interestingly, the zero shear viscosities (i.e., η0) of these formulations spanned more than two orders of magnitude. G’, storage modulus; G”, loss modulus; δ, phase angle ^Indicates that inertial effects of the rheometer head likely dominate this measurement due to low mechanical properties.

Frictional behavior of HA formulations is not fully described by standard rheology

Classically, clinical HA injections have been considered mechanical interventions with shock absorbing and lubricating modes of action. To test this hypothesis that HA is effective in lowering the friction coefficient of cartilage, we utilized a previously described tribometer to evaluate the ability of these HA formulations to lower cartilage friction. Briefly, neonatal bovine articular cartilage cylinders were mated against a polished glass counterface, compressed to 25% axial strain, and allowed to equilibrate for 60 minutes while bathed in one of the HA formulations or PBS. The glass slide was then reciprocated through a speed sweep from 0.1 to 10 mm/s, and both normal and shear loads were recorded using a custom biaxial load cell. For each speed, the friction coefficient was recorded as the ratio of the shear load to normal load at the end of the sliding cycle when the friction coefficient reached a steady value. As with viscoelastic properties, the ability of HA formulations to lubricate cartilage varied widely, with friction coefficients ranging from over 0.2 to under 0.05 (). Additionally, speed-dependence was observed for all lubricants, as would be expected for sliding within highly viscous lubricants. Because of the speed-dependence, we examined friction as a function of the Sommerfeld number, S. This normalization presents friction as a function of v sliding speed, η lubricant viscosity, d contact width, and N normal load. In performing this analysis, the question emerges as to the appropriate viscosity to use for each formulation as they all exhibit viscoelastic, non-Newtonian, shear thinning behavior. We have recently shown that the lubricating behavior of such HA formulations can be described by low shear viscosities [21], thus we incorporated the zero-shear rate viscosities (i.e., η, ) obtained from the Carreau-Yasuda curve fitting. However, upon inspection of the normalized data (), it was evident that normalization to this viscosity was not sufficient to collapse the data onto a master curve of friction versus Sommerfeld number. This fact should not be entirely surprising as it is clear that all of the formulations have different shear thinning and elastic properties (). Additionally, we and others have recently reported that HA interacts with the articular surface through bound lubricin, and it is possible that chemical modifications of these HA formulations can alter this interaction [21,39,40]. (A) All HA formulations exhibited decreased friction as a function of increased sliding speed. (B) However, presenting friction as a function of the Sommerfeld number (S, Eq 2) did not collapse all of the data onto a master friction curve when S was calculated based on η0 values obtained in Table (n = 4 samples per group). Thus, to better understand the lubricating behavior of these HA formulations, we allowed η to vary when calculating S to determine an effective lubricating viscosity, η. To calculate this parameter for each lubricant, we compared each friction sweep to a friction curve we previously obtained in the absence of HA. Specifically, we collapsed the data onto an elastoviscous curve obtained for 2 MDa dextran lubricating cartilage (). This was conducted by minimizing RMS error between the data and the model curve. This curve of friction coefficient μ, as a function of S is given by: Where, μ is the minimum friction coefficient, μ is the boundary friction coefficient, S is the Sommerfeld number at the mid-point of the transition from high to low friction, and d is a fitting parameter controlling the slope of the transition. The values obtained for 2 MDa dextran are: μ = 0.04, μ = 0.21, S = 2.7·10−6, and d = 0.62. For each lubricant, the effective viscosity was lower than the measured viscosity, in some cases by orders of magnitude. This difference, which was highly variable between the HA formulations, highlights the fact that chemical modifications of HA formulations can alter the lubricating properties in a manner not fully predicted by the measured viscosity.

Traditional rheological and viscoelastic characterization does not predict clinical outcome, but friction does

We aggregated clinical trial data for each of these HA formulations tested and extracted the change in WOMAC pain score from baseline. First, we inspected correlations between the rheological properties and maximum WOMAC change from baseline. While some rheological properties were predictive of other rheological properties [e.g., R2 = 0.92 between η( = 0.1) and G”], none of the rheological properties were predictive of clinical outcomes ( and ). In fact, the highest correlation coefficient observed was between the phase angle, δ, and change in WOMAC (R2 = 0.3), but this comparison fell well short of significance (p = 0.2). Interestingly, the rheological properties of the formulations were not predictive of the frictional behavior either. The strongest correlation; however, was between the zero shear viscosity and the friction coefficient at 0.1 mm/s (R2 = 0.61, p = 0.04, ). Additionally, in stark contrast to the rheological data, the measured friction coefficients and the effective viscosity calculated from the frictional analysis were much more predictive of the change in WOMAC scores (, ). In fact, low speed friction [μ(v = 0.1 mm/s)], high speed friction [μ(v = 10 mm/s)], and the effective viscosity (ηeff) all provided significant correlations with the aggregated clinical outcome data (R2 = 0.70, p = 0.019; R2 = 0.77, p = 0.009; and R2 = 0.78, p = 0.008, respectively).

R2 values for pair-wise comparisons of rheological properties, friction properties, and changes in WOMAC from baseline.

Red indicates poor correlations and blue indicates strong correlations. Bolded values indicate significant correlations with p < 0.05. Of note is the correlation between frictional properties and change in WOMAC. (A,B) Collection of data from all products studied indicated that rheological properties (i.e., η0 and G’) were not predictive of mean change in WOMAC score from baseline. (C,D) However, the effective lubricating viscosity (lubricating viscosity (ηeff) and friction coefficient (μ) provided strong correlations with the clinical data.

Discussion

Here, we assessed both the rheological and tribological properties of clinically approved hyaluronic acid viscosupplements and found that data obtained from cartilage friction measurements are significantly more predictive of published clinical outcomes than either rheological or viscoelastic properties as measured by traditional means. Indeed, despite the colloquial use of the term ‘viscosupplementation’, we found little evidence that these products can be judged in a pre-clinical context solely by their rheological properties measured with standard techniques. A major question remains as to connection between frictional properties of these formulations and the maximum reduction of pain reported by the WOMAC scores ( and ). There is currently growing evidence that chondrocytes are susceptible to dysfunction as a direct result of altered friction levels within a joint [44-46]. Additionally, there is a strong association between cartilage friction and wear of the articular surface [47,48]. While these factors may provide possible clues to the relationships found in this study, there is a host of possible explanations for this correlation. One particularly interesting finding of this study revealed that the widely varying viscosities of these formulations did not predict the frictional properties. In fact, the measured viscosities, η0, varied by orders of magnitude from effective viscosities, ηeff, in an unpredictable manner. This result may be linked to difficulties in measuring rheological properties in a robust and physiologically relevant manner. For highly viscous polymeric solutions such as the ones studied here, factors such as wall slip and interfacial effects may lead to this disconnect [38,49]. Thus, standard techniques that do not account for such interfacial effects may not accurately measure mechanical properties. It should be noted that for other biomolecules such as mucin [50], adsorption to a surface causes an increased local viscosity that enhances lubricating properties, and we have recently shown that a similar mechanism can occur for HA [21]. In fact, tuning the affinity of HA to the cartilage surface can drastically alter the lubricating response [51]. With this in mind, it is currently unclear how HA-stainless steel interfaces in rheological configurations mimic the physiologically relevant cartilage-HA interface. Further, we and others have recently reported that HA interacts with molecules such as lubricin bound to the articular surface [21,39,40]. This interaction with lubricin is not specific to HA and can be replicated by another viscous polysaccharide, dextran. It is hypothesized that facilitating the aggregation of HA at the articular surface allows viscous surface layers to develop, which in turn facilitate lubrication through a mechanism called viscous boundary lubrication [50]. It is possible that the molecular weight variations and the chemical modifications of the HA formulations in the present study alter such interactions with the articular surface that can either promote or inhibit effective lubrication leading to the disparities observed. While this study revealed a strong connection between lubricating properties and clinical data, there are several limitations that must be addressed. This study utilized healthy, neonatal bovine cartilage to mitigate sample to sample variations that could occur during testing. We have previously shown, however, that both injury and degeneration alter the lubrication of cartilage by HA [52,53], thus the frictional properties reported may not fully describe the lubricating effect of the HA formulations on clinically relevant tissue, and the reported friction coefficients may not fully recapitulate the in vivo situation. While HA and other synovial fluid molecules lower the cartilage friction coefficient, the structure of cartilage is also crucial to the low friction surfaces as the low permeability of the tissue allows substantial interstitial fluid pressurization [54,55]. Additionally, the rheological techniques used do not necessarily represent the state of the art, but represent standard techniques that may not capture the complex mechanical properties of these HA solutions. These techniques may not fully convey rheological phenomenon that occur at higher or lower strains, strain rates and oscillation frequencies in addition to interfacial effects that likely contribute to the frictional response. Further, the clinical trial data was not aggregated from studies conducted in an identical manner. Aspects including doses, timing of administration, timing of maximum efficacy, and study inclusion/exclusion criteria all varied between the clinical trials. It is also noted that the studies aggregated for this analysis are not exhaustive of the clinical data, but represent a subset of studies where both the clinical data were available and the lubricant was available for in vitro testing. Additionally, it should be noted that despite the strong correlations, causation is not necessarily implied. Other factors that can trend with lubricating efficacy may also play a vital role. For example, altering the chemical structure to promote effective lubrication can have a parallel effect of altering the residence time of these molecules. Thus promoting aggregation of HA at the articular surface could promote lubrication and enhance residence time simultaneously. Despite these stated limitations, this study revealed that rheological and viscoelastic properties are less predictive of clinical efficacy compared to lubricating ability.

Materials and methods

Rheological testing

To determine the role of viscosity, a commercial rheometer (TA Instruments DHR3 Rheometer, New Castle DE) was used to measure the shear rate-dependent viscosity of the lubricant baths. For the HA-based lubricants, a 40 mm diameter cone-plate set up with a 2° angle and 50 μm truncation was used in a shear rate sweep of to determine dynamic viscosities based on standard protocols from the manufacturer built into the Trios software package. To determine the pseudoplastic properties of the lubricating solutions, the shear rate () dependent dynamic viscosity (η) was fit to a Carreau-Yasuda model given by Eq 1. The parameters were determined by minimizing the root-mean-square error between the data and the model fit using a custom Excel template. Goodness of fit was reported for each curve based on the coefficient of variation of the RMS error. Additionally, this rheometer configuration (40 mm cone-plate) was utilized to determine viscoelastic properties of the solutions (i.e., storage and loss moduli, and phase angle). Preliminary evidence suggested that the linear regime for HA and modified HA solutions extends past 10% strain [56,57]. To capture this behavior, these analyses were conducted using 3% oscillatory shear strain with an angular frequency sweep from ω = 0.1 to 100 rad/sec based on protocols in the Trios software. Data are reported for a single replicate from the same lubricant formulation batch used in the tribological testing described below.

Tribological testing

Tribological testing was conducted as described recently [21,52,53]. Friction coefficients of cartilage-against-glass were measured on a custom tribometer. Cartilage samples were extracted from the patellofemoral groove of neonatal (1–3 day old) bovine stifles. These cartilage samples were extracted using a 6 mm diameter biopsy punch and sized to 2 mm thick cylinders. Cartilage was mated against a polished glass flat counterface while bathed in a lubricant bath in a tilt-pad bearing configuration [58]. Friction coefficients were measured in a stationary contact area configuration. That is, cartilage was compressed against a flat surface and reciprocated in a manner that mitigates the effects of interstitial fluid pressurization on friction coefficient measurements that can arise from active deformation of the cartilage matrix. Prior to friction coefficient measurements, samples were compressed to 25% axial strain and allowed to depressurize over the course of 1 hour resulting in equilibrium normal loads on the order of 2.5 N. Following normal force equilibrium, the glass counterface was reciprocated at predetermined speeds ranging from 0.1 to 10 mm/s, and friction coefficients were calculated as the ratio of shear load to normal load measured by a biaxial load cell. Coefficients were calculated at the end of sliding when friction had reached an equilibrium value to mitigate effects of the static friction coefficient and inertial effects that are present at the beginning of sliding at elevated speeds. To account for any misalignments, the friction coefficient was averaged for both the forward and reverse sliding directions.

Lubricant formulations and cartilage surfaces

Lubricants used in this study were phosphate buffered saline (PBS; Corning, Manassas VA). Sodium hyaluronate with 500–730 kDa molecular weight obtained from Streptococcus Equi fermentation and formulated to a final solution of 10 mg/mL in PBS (Hyalgan, Fidia Farmaceutici, Padua Italy) was used as the HA solution. Hymovis (Fidia Farmaceutici, Padua Italy), which is based on HYADD4, a hydrophobic partial hexadecyl derivative of HA with a degree of substitution ~ 2% mol/mol with respect to the polysaccharide repeating unit, provided a lubricant bath with increased viscosity at a concentration of 8 mg/mL in PBS. Additionally, other commercially available viscosupplements were tested at their clinically relevant concentrations. These solutions were Supartz (trademark of Seikugaku Corporation), Monovisc (trademark of Anika Therapeutics), Synvisc (trademark of Genzyme Corporation), and Euflexxa (trademark of Ferring BV) (Gifts from Drs. Scott Rodeo and John Kennedy, Hospital for Special Surgery).

Comparison to clinical trial data

To assess the extent to which data from friction studies and rheological characterization correlated with clinical outcomes, data was collected from published clinical trials [32,59-64]. For all data sets, the parameter chosen to represent clinical efficacy was the maximum percentage improvement in WOMAC score compared to baseline, regardless of the time point at which such maximal improvement occurred. Because placebo effects due to saline injections are often quite high, the comparison of clinical efficacy to tribological and rheological studies also included data on saline injection, using measured parameters on the properties of PBS to enable inclusion of such data in correlation analyses [9].

Statistical analysis

Rheological data from flow sweep experiments were fit to a Carreau-Yasuda model to determine the zero shear rate viscosity (Eq 1). These calculations were conducted in a custom excel file that determined the five fitting parameters through root-mean-squared error minimization. Additionally, the coefficient of variation of the RMS error were calculated and reported. Friction data were plotted as a function of S (Eq 2) and fit to a friction transition curve (Eq 3) by minimizing RMS error. Correlations between measured parameters and clinical trial data were conducted through linear regression and R2 values were reported in for each comparison. Significance was determined using a Pearson correlation coefficient.

Example flow sweep viscosity data along with the associated Carreau-Yasuda fit.

(TIF) Click here for additional data file.

Oscillatory shear data for all HA formulations.

A cross-over frequency was not evident within the operating conditions for all of the formulations. (TIF) Click here for additional data file.
Table 1

Carreau-Yasuda model parameters for 6 clinically approved HA viscosupplements.

Interestingly, the zero shear viscosities (i.e., η0) of these formulations spanned more than two orders of magnitude.

Lubricantη0 (Pa·s)η (Pa·s)λanCV(RMSD)
Euflexxa100.090.451.910.940.020.08
Hymovis190.370.0013.160.400.390.08
Hyalgan0.500.002117.200.600.880.09
Monovisc6.460.000.250.600.480.03
Supartz2.110.000.090.600.390.05
Synvisc124.850.003.860.600.210.03
Table 2

Viscoelastic properties of the HA formulations for three different angular frequencies, ω.

ω = 0.1 rad/sω = 1.0 rad/sω = 10. rad/s
FormulationG' (Pa)G'' (Pa)δ (°)G' (Pa)G'' (Pa)δ (°)G' (Pa)G'' (Pa)δ (°)
Euflexxa5.1710.0062.6831.9026.1139.3580.8434.8824.70
Hyalgan0.450.4142.650.430.5555.580.67^1.49^160.95^
Hymovis36.0319.0127.8263.2317.0115.0785.4415.1310.65
Monovisc0.080.6683.261.335.2276.2615.4128.0169.61
Supartz0.350.5457.040.522.4178.887.1314.1581.43
Synvisc30.9323.1836.8671.6827.6721.12111.5124.3912.90

G’, storage modulus; G”, loss modulus; δ, phase angle

^Indicates that inertial effects of the rheometer head likely dominate this measurement due to low mechanical properties.

  57 in total

Review 1.  American College of Rheumatology 2012 recommendations for the use of nonpharmacologic and pharmacologic therapies in osteoarthritis of the hand, hip, and knee.

Authors:  Marc C Hochberg; Roy D Altman; Karine Toupin April; Maria Benkhalti; Gordon Guyatt; Jessie McGowan; Tanveer Towheed; Vivian Welch; George Wells; Peter Tugwell
Journal:  Arthritis Care Res (Hoboken)       Date:  2012-04       Impact factor: 4.794

Review 2.  Treatment of osteoarthritis of the knee: evidence-based guideline, 2nd edition.

Authors:  David S Jevsevar
Journal:  J Am Acad Orthop Surg       Date:  2013-09       Impact factor: 3.020

Review 3.  Consensus statement on viscosupplementation with hyaluronic acid for the management of osteoarthritis.

Authors:  Yves Henrotin; Raghu Raman; Pascal Richette; Hervé Bard; Jörg Jerosch; Thierry Conrozier; Xavier Chevalier; Alberto Migliore
Journal:  Semin Arthritis Rheum       Date:  2015-04-30       Impact factor: 5.532

4.  Role of hyaluronic acid in joint lubrication.

Authors:  D A Swann; E L Radin; M Nazimiec; P A Weisser; N Curran; G Lewinnek
Journal:  Ann Rheum Dis       Date:  1974-07       Impact factor: 19.103

Review 5.  Hyaluronans: is clinical effectiveness dependent on molecular weight?

Authors:  Peter C Vitanzo; Brian J Sennett
Journal:  Am J Orthop (Belle Mead NJ)       Date:  2006-09

6.  Adaptive multimode lubrication in natural synovial joints and artificial joints.

Authors:  T Murakami; H Higaki; Y Sawae; N Ohtsuki; S Moriyama; Y Nakanishi
Journal:  Proc Inst Mech Eng H       Date:  1998       Impact factor: 1.617

7.  Microscale frictional strains determine chondrocyte fate in loaded cartilage.

Authors:  Edward D Bonnevie; Michelle L Delco; Lena R Bartell; Naveen Jasty; Itai Cohen; Lisa A Fortier; Lawrence J Bonassar
Journal:  J Biomech       Date:  2018-04-25       Impact factor: 2.712

8.  Intraarticular sodium hyaluronate (Hyalgan) in the treatment of patients with osteoarthritis of the knee: a randomized clinical trial. Hyalgan Study Group.

Authors:  R D Altman; R Moskowitz
Journal:  J Rheumatol       Date:  1998-11       Impact factor: 4.666

9.  The effects of intraarticularly injected sodium hyaluronate on levels of intact aggrecan and nitric oxide in the joint fluid of patients with knee osteoarthritis.

Authors:  Kohei Kobayashi; Satoshi Matsuzaka; Yuko Yoshida; Satoshi Miyauchi; Yuichi Wada; Hideshige Moriya
Journal:  Osteoarthritis Cartilage       Date:  2004-07       Impact factor: 6.576

10.  Hyaluronan injection in murine osteoarthritis prevents TGFbeta 1-induced synovial neovascularization and fibrosis and maintains articular cartilage integrity by a CD44-dependent mechanism.

Authors:  Jun Li; Daniel J Gorski; Wendy Anemaet; Jennifer Velasco; Jun Takeuchi; John D Sandy; Anna Plaas
Journal:  Arthritis Res Ther       Date:  2012-06-21       Impact factor: 5.156

View more
  6 in total

1.  Distinct tribological endotypes of pathological human synovial fluid reveal characteristic biomarkers and variation in efficacy of viscosupplementation at reducing local strains in articular cartilage.

Authors:  R M Irwin; E Feeney; C Secchieri; D Galesso; I Cohen; F Oliviero; R Ramonda; L J Bonassar
Journal:  Osteoarthritis Cartilage       Date:  2020-02-24       Impact factor: 6.576

2.  Injection route affects intra-articular hyaluronic acid distribution and clinical outcome in viscosupplementation treatment for knee osteoarthritis: a combined cadaver study and randomized clinical trial.

Authors:  Jun Xiao; Yong Hu; Lin Huang; Zhi-Fa Huang; Wei-Zhou Jiang; Yu-Qiang Luo; Meng-Yan Jia; Di Chen; Zhan-Jun Shi
Journal:  Drug Deliv Transl Res       Date:  2021-02       Impact factor: 4.617

3.  The clot thickens: Autologous and allogeneic fibrin sealants are mechanically equivalent in an ex vivo model of cartilage repair.

Authors:  Rebecca M Irwin; Lawrence J Bonassar; Itai Cohen; Andrea M Matuska; Jacqueline Commins; Brian Cole; Lisa A Fortier
Journal:  PLoS One       Date:  2019-11-08       Impact factor: 3.240

4.  A Hyaluronic Acid-Based Formulation with Simultaneous Local Drug Delivery and Antioxidant Ability for Active Viscosupplementation.

Authors:  Pooyan Makvandi; Francesca Della Sala; Mario di Gennaro; Nicola Solimando; Maurizio Pagliuca; Assunta Borzacchiello
Journal:  ACS Omega       Date:  2022-03-15

5.  On the Dependence of Rheology of Hyaluronic Acid Solutions and Frictional Behavior of Articular Cartilage.

Authors:  David Rebenda; Martin Vrbka; Pavel Čípek; Evgeniy Toropitsyn; David Nečas; Martin Pravda; Martin Hartl
Journal:  Materials (Basel)       Date:  2020-06-11       Impact factor: 3.623

Review 6.  Biological molecules in dental applications: hyaluronic acid as a companion biomaterial for diverse dental applications.

Authors:  Rami Al-Khateeb; Iwona Olszewska-Czyz
Journal:  Heliyon       Date:  2020-04-06
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.