Detection of left atrial appendage thrombi by third-generation dual-source dual-energy CT: Iodine concentration versus conventional enhancement measurements.

Wenhuan Li1, Fangfang Yu1, Weiwei Zhu2, Weiguo Zhang3, Tao Jiang4.   

Abstract

BACKGROUND: Dual-energy computed tomography (DECT) can differentiate iodine from other materials through the material decomposition technique. The purpose of this study was to compare the diagnostic performance of DECT-derived iodine concentration (mg/ml) with conventional enhancement measurements (HU), in detecting left atrial appendage (LAA) thrombi and differentiating thrombi from circulatory stasis in atrial fibrillation (AF) patients referred for catheter ablation.
METHODS: Consecutive patients were prospectively recruited and scanned using a third-generation dual-source CT system in dual-energy mode. Regions of interest were placed inside the filling defect in the LAA and ascending aorta (AA) of the same sections, to determine iodine concentration and the LAA/AA HU ratio. The diagnostic performance of iodine concentration and LAA/AA HU ratios were compared using transesophageal echocardiography (TEE) as the reference standard.
RESULTS: Among 302 patients, 10 thrombi and 27 cases with spontaneous echo contrast (SEC) were detected by TEE. Diagnostic accuracy, sensitivity, specificity, positive predictive value, and negative predictive value of iodine concentration were superior to those of LAA/AA HU ratios (iodine concentration: 99.7%, 100%, 99.7%, 90.9%, and 100% vs. LAA/AA HU ratios: 96.0%, 100%, 95.9%, 45.5%, and 100%) in detecting LAA thrombi. The area under the receiver operating characteristic curve of iodine concentration (0.996; 0.898-1.000) was significantly larger than that of the LAA/AA HU ratio (0.881; 0.733-0.964) in differentiating thrombi from circulatory stasis (p < 0.05).
CONCLUSIONS: DECT-derived iodine concentration was associated with improved diagnostic accuracy compared with conventional enhancement measurements in detecting LAA thrombi and differentiating thrombi from circulatory stasis in AF patients.
Copyright © 2019 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2019        PMID: 31072634     DOI: 10.1016/j.ijcard.2019.04.079

Source DB:  PubMed          Journal:  Int J Cardiol        ISSN: 0167-5273            Impact factor:   4.164


  2 in total

1.  Cardiac Computed Tomography Versus Transesophageal Echocardiography for the Detection of Left Atrial Appendage Thrombus: A Systemic Review and Meta-Analysis.

Authors:  Shandong Yu; Heping Zhang; Hongwei Li
Journal:  J Am Heart Assoc       Date:  2021-11-19       Impact factor: 6.106

2.  Detection of left atrial appendage thrombus by dual-energy computed tomography-derived imaging biomarkers in patients with atrial fibrillation.

Authors:  Wenhuan Li; Mingxi Liu; Fangfang Yu; Weiwei Zhu; Xianbo Yu; Xiaojuan Guo; Qi Yang
Journal:  Front Cardiovasc Med       Date:  2022-07-22
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.