Hossam Selim1, José Trull2, Miguel Delgado Prieto3, Rubén Picó4, Luis Romeral5, Crina Cojocaru6.
Abstract
Nondestructive testing of metallic objects that may contain embedded defects of different sizes is an important application in many industrial branches for quality control. Most of these techniques allow defect detection and its approximate localization, but few methods give enough information for its 3D reconstruction. Here we present a hybrid laser-transducer system that combines remote, laser-generated ultrasound excitation and noncontact ultrasonic transducer detection. This fully noncontact method allows access to scan areas on different object's faces and defect details from different angles/perspectives. This hybrid system can analyze the object's volume data and allows a 3D reconstruction image of the embedded defects. As a novelty for signal processing improvement, we use a 2D apodization window filtering technique, applied along with the synthetic aperture focusing algorithm, to remove the undesired effects due to side lobes and wide-angle reflections of propagating ultrasound waves, thus enhancing the resulting 3D image of the defect. Finally, we provide both qualitative and quantitative volumetric results that yield valuable information about defect location and size.Entities:
Keywords: 3D reconstruction; NDT; SAFT; apodization; defects; laser ultrasonics; noncontact transducers; synthetic aperture; weighting function
Year: 2019 PMID: 31072063 PMCID: PMC6539283 DOI: 10.3390/s19092138
Source DB: PubMed Journal: Sensors (Basel) ISSN: 1424-8220 Impact factor: 3.576
Figure 1Beamwidth angle Δθ for a point scatterer at depth Z; when the point scatterer is deeper Z2 > Z1, the synthetic aperture size (ΔX) changes accordingly. The apodization window size should be adapted to the synthetic aperture window size.
Figure 2(a) Experimental setup used for the excitation and detection of ultrasound waves; (b) Schematic representation of the object under study with the three-face scan areas. Different Cartesian axes are represented at each scan face; (c) Representation of the 3D object under investigation using the synthetic aperture focusing technique (SAFT) algorithm with the scanning area at one of the faces with the Exciter (T), Receiver (R), and scatterer point in volume.
Figure 3The SAFT algorithm results of the three-face experiment: (a) X1Y1 plane slice for face 1 at Z1 = 99 mm; (b) X1Z1 plane slice for face 1 at Y1 = 40 mm; (c) X2Y2 plane slice for face 2 at Z2 = 95 mm; (d) X2Z2 plane slice for face 2 at Y2 = 51 mm; and (e) X3Y3 plane slice for face 3 at Z3 = 70 mm f) X3Z3 plane slice for face 3 at Y3 = 36 mm. (color map at bottom right applies to all subfigures).
Figure 43D reconstruction of the defect by combining the resulting SAFT images from the three faces and superimposing the actual cylindrical shape of the defect. (a) Isometric view resulting from face 1 (front view/X1Y1) scan area inspection by applying a reject threshold for data with an intensity below 65%; (b) Front view resulting from face 1 scan area inspection by applying a reject threshold for data with intensity below 65%; (c) Isometric view resulting from face 2 (Side view/X2Y2) scan area inspection by applying a reject threshold for data with an intensity below 65%; (d) Side view resulting from face 2 scan area inspection by applying a reject threshold for data with an intensity below 65%; (e) Isometric view resulting from face 3 (Top view/X3Y3) scan area inspection by applying a reject threshold for data with an intensity below 65%; (f) Top view resulting from face 3 scan area inspection by applying a reject threshold for data with an intensity below 65%; (g) Isometric view resulting from the 3d reconstruction by applying a reject threshold for data with an intensity below 65%; (h) isometric view by applying a stricter reject threshold for data with an intensity below 85%. (Color map at bottom right applies to all subfigures.)