Literature DB >> 31071052

A Dual-Band Wireless Power Transmission System for Evaluating mm-Sized Implants.

Yaoyao Jia, S Abdollah Mirbozorgi, Pengcheng Zhang, Omer T Inan, Wen Li, Maysam Ghovanloo.   

Abstract

Distributed neural interfaces made of many mm-sized implantable medical devices (IMDs) are poised to play a key role in future brain-computer interfaces because of less damage to the surrounding tissue. Evaluating them wirelessly at preclinical stage (e.g., in a rodent model), however, is a major challenge due to weak coupling and significant losses, resulting in limited power delivery to the IMD within a nominal experimental arena, like a homecage, without surpassing the specific absorption rate limit. To address this problem, we present a dual-band EnerCage system with two multi-coil inductive links, which first deliver power at 13.56 MHz from the EnerCage (46 × 24 × 20 cm3) to a headstage (18 × 18 × 15 mm3, 4.8 g) that is carried by the animal via a 4-coil inductive link. Then, a 60 MHz 3-coil inductive link from the headstage powers up the small IMD (2.5 × 2.5 × 1.5 mm3, 15 mg), which in this case is a free floating, wirelessly powered, implantable optical stimulator (FF-WIOS). The power transfer efficiency and power delivered to the load (PDL) from EnerCage to the headstage at 7 cm height were 14.9%-22.7% and 122 mW; and from headstage to FF-WIOS at 5 mm depth were 18% and 2.7 mW, respectively. Bidirectional data connectivity between EnerCage-headstage was established via bluetooth low energy. Between headstage and FF-WIOS, on-off keying and load-shift-keying were used for downlink and uplink data, respectively. Moreover, a closed-loop power controller stabilized PDL to both the headstage and the FF-WIOS against misalignments.

Entities:  

Mesh:

Year:  2019        PMID: 31071052      PMCID: PMC6728165          DOI: 10.1109/TBCAS.2019.2915649

Source DB:  PubMed          Journal:  IEEE Trans Biomed Circuits Syst        ISSN: 1932-4545            Impact factor:   3.833


  30 in total

1.  A mm-sized wirelessly powered and remotely controlled locomotive implant.

Authors:  Daniel Pivonka; Anatoly Yakovlev; Ada S Y Poon; Teresa Meng
Journal:  IEEE Trans Biomed Circuits Syst       Date:  2012-12       Impact factor: 3.833

2.  An Adaptive Reconfigurable Active Voltage Doubler/Rectifier for Extended-Range Inductive Power Transmission.

Authors:  Hyung-Min Lee; Maysam Ghovanloo
Journal:  IEEE Trans Circuits Syst II Express Briefs       Date:  2012       Impact factor: 3.292

3.  Design and Optimization of a 3-Coil Inductive Link for Efficient Wireless Power Transmission.

Authors:  Mehdi Kiani; Uei-Ming Jow; Maysam Ghovanloo
Journal:  IEEE Trans Biomed Circuits Syst       Date:  2011-07-14       Impact factor: 3.833

4.  An RFID-Based Closed-Loop Wireless Power Transmission System for Biomedical Applications.

Authors:  Mehdi Kiani; Maysam Ghovanloo
Journal:  IEEE Trans Circuits Syst II Express Briefs       Date:  2010-04-01       Impact factor: 3.292

5.  EnerCage: a smart experimental arena with scalable architecture for behavioral experiments.

Authors:  Peter McMenamin; Mehdi Kiani; Joseph R Manns; Maysam Ghovanloo
Journal:  IEEE Trans Biomed Eng       Date:  2013-08-15       Impact factor: 4.538

6.  Modeling and optimization of printed spiral coils in air, saline, and muscle tissue environments.

Authors:  M Ghovanloo
Journal:  IEEE Trans Biomed Circuits Syst       Date:  2009-08-25       Impact factor: 3.833

7.  Failure mode analysis of silicon-based intracortical microelectrode arrays in non-human primates.

Authors:  James C Barrese; Naveen Rao; Kaivon Paroo; Corey Triebwasser; Carlos Vargas-Irwin; Lachlan Franquemont; John P Donoghue
Journal:  J Neural Eng       Date:  2013-11-12       Impact factor: 5.379

8.  320-channel active probe for high-resolution neuromonitoring and responsive neurostimulation.

Authors:  Ruslana Shulyzki; Karim Abdelhalim; Arezu Bagheri; M Tariqus Salam; Carlos M Florez; Jose Luis Perez Velazquez; Peter L Carlen; Roman Genov
Journal:  IEEE Trans Biomed Circuits Syst       Date:  2014-06-04       Impact factor: 3.833

9.  Implanted neural electrodes cause chronic, local inflammation that is correlated with local neurodegeneration.

Authors:  George C McConnell; Howard D Rees; Allan I Levey; Claire-Anne Gutekunst; Robert E Gross; Ravi V Bellamkonda
Journal:  J Neural Eng       Date:  2009-08-21       Impact factor: 5.379

10.  Retinotopy within rat primary visual cortex using optical imaging.

Authors:  C Gias; N Hewson-Stoate; M Jones; D Johnston; J E Mayhew; P J Coffey
Journal:  Neuroimage       Date:  2005-01-01       Impact factor: 6.556

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.