Literature DB >> 31070956

Effects of high PEEP and fluid administration on systemic circulation, pulmonary microcirculation, and alveoli in a canine model.

Huaiwu He1, Qinhe Hu1,2, Yun Long1, Xu Wang1, Rui Zhang1, Longxiang Su1, Dawei Liu1, Can Ince3.   

Abstract

This study aimed to determine the response of systemic circulation, pulmonary microcirculation, and alveoli to high positive end-expiratory pressure (PEEP) in a canine model. This study was conducted in nine mixed-breed dogs on mechanical ventilation under anesthesia. The PEEP was initially set at 5 cmH2O (PEEP5), the PEEP was then increased to 25 cmH2O (PEEP25), and then saline was used for fluid loading. Data were obtained at the following time points: PEEP5; PEEP25 prefluid loading; and PEEP25 postfluid loading. The images of subpleural lung microcirculation were assessed by sidestream dark-field microscopy, and the hemodynamic data were collected from pulse contour waveform-derived measurements. Compared with PEEP5, the lung microvascular flow index (MFI, 2.3 ± 0.8 versus 0.9 ± 0.8, P = 0.001), lung perfused vessel density (PVD, 4.2 ± 2 versus 1.5 ± 1.8, P = 0.004), lung proportion of perfused vessel (PPV, 93 ± 14 versus 40 ± 4, P = 0.003), cardiac output (2.5 ± 0.6 versus 1.4 ± 0.5, P = 0.001), and mean blood pressure (116 ± 24 versus 91 ± 31, P = 0.012) were significantly lower at PEEP25 prefluid loading. After fluid loading, there were no significant differences in cardiac output or mean arterial pressure between the PEEP5 and PEEP25 postfluid loading levels. However, the lung microcirculatory MFI, PVD, and PPV at PEEP25 postfluid loading remain lower than at PEEP5. A significant increase in septal thickness was found at PEEP25 postfluid loading relative to septal thickness at PEEP25 prefluid loading (25.98 ± 5.31 versus 40.76 ± 7.9, P = 0.001). Under high PEEP, systemic circulation was restored after fluid loading, but lung microcirculation was not. Moreover, the septal thickness of alveoli significantly increased after fluid loading.NEW & NOTEWORTHY An excessively high positive end-expiratory pressure (PEEP) can impair the systemic circulation and alveolar microcirculation. In the high-PEEP condition, fluid loading restored the systemic circulation but did not affect the impaired lung microcirculation. The septal thickness of the alveoli significantly increased after fluid loading in the high-PEEP condition.

Entities:  

Keywords:  PEEP; lung microcirculation; mechanical ventilation; sidestream dark field

Mesh:

Year:  2019        PMID: 31070956     DOI: 10.1152/japplphysiol.00571.2018

Source DB:  PubMed          Journal:  J Appl Physiol (1985)        ISSN: 0161-7567


  4 in total

1.  Lactate guided resuscitation-nothing is more dangerous than conscientious foolishness.

Authors:  Paul E Marik
Journal:  J Thorac Dis       Date:  2019-09       Impact factor: 2.895

2.  A Barrier to Defend - Models of Pulmonary Barrier to Study Acute Inflammatory Diseases.

Authors:  Anna Herminghaus; Andrey V Kozlov; Andrea Szabó; Zoltán Hantos; Severin Gylstorff; Anne Kuebart; Mahyar Aghapour; Bianka Wissuwa; Thorsten Walles; Heike Walles; Sina M Coldewey; Borna Relja
Journal:  Front Immunol       Date:  2022-07-07       Impact factor: 8.786

3.  Use of intraoperative ultrasonography for identification and management of pneumothorax caused by iatrogenic diaphragm defect: a case report and literature review.

Authors:  Qiang Han; Beibei Wang; Aijun Xu
Journal:  J Int Med Res       Date:  2020-01       Impact factor: 1.671

4.  Thoracic, Peripheral, and Cerebral Volume, Circulatory and Pressure Responses To PEEP During Simulated Hemorrhage in a Pig Model: a Case Study.

Authors:  Leslie D Montgomery; Richard W Montgomery; Michael Bodo; Richard T Mahon; Frederick J Pearce
Journal:  J Electr Bioimpedance       Date:  2021-12-27
  4 in total