Yuan Zhao1, Fangjie Zheng1, Wei Ke1, Wei Zhang2, Lixia Shi1, Han Liu1.
Abstract
Establishing a simple and accurate assay for detecting Microcystin-LR (MC-LR) is of significant important for the environment and human health. Herein, we develop a ratiometric surface-enhanced Raman scattering (SERS) aptasensor based on internal standard (IS) methods for the sensitive and reproducible quantitative detection of MC-LR. Gap-tethered SERS-active Au@AgAu nanoparticles (NPs) are successfully prepared and the gap sizes are adjustable by simply adjusting the acidity. Gap-tethered Au@AgAu NPs exhibit gap-tunable amplified SERS activity and are served as SERS tags. The graphene oxide (GO)/Fe3O4 NPs demonstrate a unique and stable Raman band from the graphitic component, making them an ideal IS for quantitative Raman analysis. In principle, Au@gap@AgAu NPs are assembled with GO/Fe3O4 NPs depending on the π-π stacking interaction between GO and MC-LR aptamers. In the presence of MC-LR, Au@gap@AgAu NPs are dissociated from GO/Fe3O4 NPs due to the affinity of aptamer, leading to the changes of Raman intensity of SERS tags. Quantitatively, upon correction by the IS Raman signals, the limit of detection (LOD) is as low as 9.82 pM for MC-LR. The developed protocol provides a simple and rapid approach for the sensitive and quantitative detection of MC-LR and shows great promise for applications in complex systems.Entities:
Mesh:
Substances:
Year: 2019 PMID: 31066265 DOI: 10.1021/acs.analchem.9b00348
Source DB: PubMed Journal: Anal Chem ISSN: 0003-2700 Impact factor: 6.986