Literature DB >> 3106501

Quantitation of free kappa light chains in serum and urine using a monoclonal antibody based inhibition enzyme-linked immunoassay.

S M Axiak, L Krishnamoorthy, J Guinan, R L Raison.   

Abstract

The murine monoclonal antibody K-1-21 with specificity for free but not heavy chain-associated kappa chains was used to develop an inhibition enzyme immunoassay for quantitation of free kappa chains in serum and urine. The assay utilizes a biotin conjugate of the monoclonal antibody and has an effective working concentration range of 0.5-50 micrograms/ml free kappa chain. Normal serum and urine yielded mean values of 1.2 and 4.9 micrograms/ml respectively using this assay system. Serum levels in patients with kappa chain myelomatosis ranged from 2 to 1700 micrograms/ml while serum from patients with lambda chain malignancies exhibited normal free kappa chain levels. The importance of the ability to readily quantitate light chains in serum was demonstrated by the finding in one patient of an absence of free kappa chains in the urine despite elevated levels of serum kappa chains. A significant drop in serum-free kappa chain levels was observed in this patient following a course of chemotherapy. The assay should prove valuable in the diagnosis, prognosis and monitoring of B cell neoplasias characterized by free kappa light chain secretion.

Entities:  

Mesh:

Substances:

Year:  1987        PMID: 3106501     DOI: 10.1016/0022-1759(87)90043-3

Source DB:  PubMed          Journal:  J Immunol Methods        ISSN: 0022-1759            Impact factor:   2.303


  4 in total

1.  Immunoturbidimetric assay for estimating free light chains of immunoglobulins in urine and serum.

Authors:  C R Tillyer; J Iqbal; J Raymond; M Gore; T J McIlwain
Journal:  J Clin Pathol       Date:  1991-06       Impact factor: 3.411

2.  Differences in kappa to lambda (kappa:lambda) ratios of serum and urinary free light chains.

Authors:  M Abe; T Goto; M Kosaka; D Wolfenbarger; D T Weiss; A Solomon
Journal:  Clin Exp Immunol       Date:  1998-02       Impact factor: 4.330

3.  The effect of circulating antigen on radioimmunodetection and monoclonal antibody localisation: studies in a normal rat model.

Authors:  D R McKay; G J Bautovich; M R Wilson; K Z Walker
Journal:  Eur J Nucl Med       Date:  1989

4.  Immunodiagnostic capabilities of anti-free immunoglobulin light chain monoclonal antibodies.

Authors:  Sandra Davern; Lian X Tang; Teresa K Williams; Sallie D Macy; Jonathan S Wall; Deborah T Weiss; Alan Solomon
Journal:  Am J Clin Pathol       Date:  2008-11       Impact factor: 2.493

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.