Literature DB >> 31064313

Biomechanical in vitro evaluation of a ready-to-use calcium phosphate cement implanted to augment intramedullary nail fixation of a three-part humeral head fracture model.

Dag Grünewald1, Elia Langenmair2, Anja Hirschmüller3, Dirk Maier3, Norbert P Südkamp3, Lukas Konstantinidis3.   

Abstract

The aim of this study was the dynamic biomechanical evaluation of a ready-to-use oil-based calcium phosphate cement paste implanted to augment intramedullary nail fixation of a three-part humeral head fracture model. Fractures in the osteoporotic bone are often fractures of the proximal humerus. Secondary fracture displacements due to cut-out in osteoporotic bone have been observed in up to 13% of cases. Procedures have been developed to augment fracture fixation with polymethylmethacrylate to increase stability, but there are still unsolved challenges relating to its material-specific properties. Calcium phosphate cement could be a biological alternative in the augmentation of osteoporotic fractures because of its more favourable material properties. Fracture fixation was performed on eight pairs of human cadaveric bones to stabilize a standardized three-part humeral head fracture model by implantation of the Targon® PH (Braun-Aesculap AG, Tuttlingen, Germany) intramedullary nail and insertion of three head screws and two bicortical shaft screws. The procedure was randomized, and one bone of each pair received calcium phosphate cement augmentation. Custom-made cannulated screws with an open lateral slot facilitated augmentation, making it possible to cement the threaded portion of the screw (1-mL calcium phosphate cement/screw). After the calcium phosphate cement had hardened, the humeri were subjected to dynamic axial loading. Load was progressively increased, monitored by ultrasound-based motion analysis, and total deformation was recorded. Load testing continued until implant failure. The augmented group withstood significantly more cycles before implant failure. The average initial stiffness showed a significant difference between the two study groups. Ultrasonic sensor technology was used to measure angular displacement during testing and a significant difference was found. Calcium phosphate cement offers a potential alternative to implant augmentation in the treatment of osteoporotic humeral head fractures. Future studies are required to confirm these observations clinically in vivo.

Entities:  

Keywords:  Proximal humerus; augmentation; biomechanical testing/analysis; calcium phosphate cement; fracture; nail fixation; osteoporosis

Mesh:

Substances:

Year:  2019        PMID: 31064313     DOI: 10.1177/0954411919848625

Source DB:  PubMed          Journal:  Proc Inst Mech Eng H        ISSN: 0954-4119            Impact factor:   1.617


  1 in total

1.  Angle-stable polyaxial locked plating with and without polymethylmethacrylate cement augmentation for proximal humeral fractures in elderly.

Authors:  Sheer Ahmad Hakimi; Katharina Schumacher; Andrej Ring
Journal:  Jt Dis Relat Surg       Date:  2021-11-19
  1 in total