Literature DB >> 31063886

Cascade catalysis-initiated radical polymerization amplified impedimetric immunosensor for ultrasensitive detection of carbohydrate antigen 15-3.

Chi Zhang1, Dongsheng Zhang1, Zhanfang Ma2, Hongliang Han3.   

Abstract

Efficient signal amplification strategies are crucial for ultrasensitive detection of tumor markers. Herein, a new signal amplification strategy by coupling cascade catalysis-initiated radical polymerization with impedimetric immunoassay was proposed for ultrasensitive detection of carbohydrate antigen 15-3 (CA15-3). Copper-based metal-organic framework nanoparticles (Cu-MOF), as peroxidase mimics, combined with CA15-3 antibody (Ab2) and glucose oxidase (GOx) were employed as immunoprobes to initiate radical polymerization by cascade catalysis. In this work, the oxidation of glucose was catalyzed by GOx to generate hydrogen peroxide (H2O2), which reacted with acetylacetone (ACAC) via Cu-MOF catalysis to yield ACAC radicals for the polymerization of N-isopropylacrylamide (NIPAM). The polymer, poly (N-isopropylacrylamide) (PNIPAM), was generated in situ from the radical polymerization. As resistance enhancer, PNIPAM was covered on electrode surface to amplify resistance value by its poor conductivity. With the help of polymerization-based amplification, the resistance differences caused by target were improved significantly. Under optimum conditions, the designed biosensor showed wide detection ranges from 10 μU/mL to 10 mU/mL and 10 mU/mL to 100 U/mL, with ultralow detection limit of 5.06 μU/mL for CA15-3. Such an approach opened a new avenue for signal amplification, thus offering an ultrasensitive detection platform for a broad range of tumor markers.
Copyright © 2019 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Carbohydrate antigen 15-3; Cascade catalysis; Impedimetric biosensor; Metal-organic frameworks; Radical polymerization; Signal amplification

Mesh:

Substances:

Year:  2019        PMID: 31063886     DOI: 10.1016/j.bios.2019.04.049

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  2 in total

1.  Ultrasensitive amperometric immunosensor for the prostate specific antigen by exploiting a Fenton reaction induced by a metal-organic framework nanocomposite of type Au/Fe-MOF with peroxidase mimicking activity.

Authors:  Jiejie Feng; Huiqiang Wang; Zhanfang Ma
Journal:  Mikrochim Acta       Date:  2020-01-06       Impact factor: 5.833

Review 2.  A Comprehensive Review of Metal-Organic Framework: Synthesis, Characterization, and Investigation of Their Application in Electrochemical Biosensors for Biomedical Analysis.

Authors:  Zahra Dourandish; Somayeh Tajik; Hadi Beitollahi; Peyman Mohammadzadeh Jahani; Fariba Garkani Nejad; Iran Sheikhshoaie; Antonio Di Bartolomeo
Journal:  Sensors (Basel)       Date:  2022-03-14       Impact factor: 3.576

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.