Literature DB >> 31061061

ABO blood type and risk of porcine bioprosthetic aortic valve degeneration: SWEDEHEART observational cohort study.

Michael Persson1,2, Gustaf Edgren3,4, Magnus Dalén1,2, Natalie Glaser1,4, Martin L Olsson5,6, Anders Franco-Cereceda1,2, Martin J Holzmann7,8, Ulrik Sartipy1,2.   

Abstract

OBJECTIVE: Blood type A antigen on porcine aortic bioprostheses might initiate an immune reaction leading to an increased frequency of structural valve deterioration in patients with blood type B or O. The aim was to analyse the association between ABO blood type and porcine bioprosthetic aortic valve degeneration.
DESIGN: Observational nationwide cohort study.
SETTING: Swedish population-based study. PARTICIPANTS: Adult patients (n=3417) who underwent surgical aortic valve replacement and received porcine bioprosthetic aortic valves between 1995 and 2012 from the Swedish Web system for Enhancement and Development of Evidence-based care in Heart disease Evaluated According to Recommended Therapies register. The study database was enriched with information from other national registers. EXPOSURE: The patients were categorised into type A/AB and type B/O blood groups. PRIMARY AND SECONDARY OUTCOME MEASURES: Primary outcome measure was aortic valve reoperation, and secondary outcomes were heart failure and all-cause mortality. We report risk estimates that account for the competing risk of death.
RESULTS: In total, 3417 patients were identified: 1724 (50.5%) with blood type A/AB and 1693 (49.5%) with blood type B/O. Both groups had similar baseline characteristics. The cumulative incidence of aortic valve reoperation was 3.4% (95% CI 2.5% to 4.4%) and 3.6% (95% CI 2.6% to 4.6%) in the type B/O and the A/AB group, respectively, at 15 years of follow-up (absolute risk difference: -0.2% (95% CI -1.5% to 1.2%)). There was no significantly increased risk for aortic valve reoperation in patients with blood type B/O compared with type A/AB (HR 0.95, 95% CI 0.62 to 1.45). There was no significant difference in absolute or relative risk of heart failure or death between the groups.
CONCLUSIONS: We found no significant association between patient blood type and clinical manifestations of structural valve deterioration following porcine aortic valve replacement. Our findings suggest that it is safe to use porcine bioprosthetic valves without consideration of ABO blood type in the recipient. TRIAL REGISTRATION NUMBER: NCT02276950. © Author(s) (or their employer(s)) 2019. Re-use permitted under CC BY-NC. No commercial re-use. See rights and permissions. Published by BMJ.

Entities:  

Keywords:  adult cardiology; cardiac epidemiology; cardiac surgery; epidemiology; valvular heart disease

Mesh:

Substances:

Year:  2019        PMID: 31061061      PMCID: PMC6502064          DOI: 10.1136/bmjopen-2019-029109

Source DB:  PubMed          Journal:  BMJ Open        ISSN: 2044-6055            Impact factor:   2.692


Data were obtained from high-quality national Swedish health data registers including Swedish Web system for Enhancement and Development of Evidence-based care in Heart disease Evaluated According to Recommended Therapies. The study exposure, that is, blood group, is genetically determined, and associations between exposure and outcomes are therefore robust to measured and unmeasured confounding. Other strengths of the study are the reporting of both relative and absolute risks, and the long and complete follow-up. One limitation of the study was that the porcine blood type for each implanted valve was not known. Another limitation was that we were unable to precisely measure structural valve deterioration, and had to rely on surrogate endpoints.

Introduction

Bioprosthetic aortic valve replacement with bovine or porcine tissue is one of the few xenotransplant procedures in common practice. Ionescu et al performed the first porcine bioprosthetic heart valve procedures implanted in mitral, tricuspid and aortic positions in 1967.1 Since then, the use of biological heart valves has increased to become the most common type of heart valve implanted.2 The primary advantage of bioprosthetic valves is that they do not require anticoagulation. The European guidelines from 2017 include a class I level C recommendation to choose a bioprosthetic valve according to patient desire, when good-quality anticoagulation is unlikely or contraindicated, and for reoperation for mechanical valve thrombosis despite good long-term anticoagulant control.3 The main disadvantage of biological prostheses is the risk of structural valve deterioration.4 Structural valve deterioration presents as calcification, leaflet thickening, reduced leaflet motion and tearing. Some factors in this process are known, but research suggests that there are additional unknown contributing mechanisms. The most accepted hypothesis is that various immune responses and mechanical stress results in activation of immune cells and complement factors causing fibrosis, thrombosis and calcification.4 Xenogeneic carbohydrate structures and glycans have been shown to remain on commercial bioprosthetic valves even after pretreatment.5–7 Several studies have shown a humoral response in patients after bioprosthetic valve implants, including increased levels of IgM and IgG levels against the major glycan xenoantigen galactose-α-1,3-galactose (Galα(1-3)Gal), an ABO-like oligosaccharide.8–10 Porcine species express only the A and O blood groups of the ABO system, with type A phenotype the more common.11 12 Thus, A antigen on bioprosthetic valves could trigger an immunogenic response in blood type B/O patients due to the presence of anti-A antibodies, similar to an ABO-mismatched organ transplant or blood transfusion. It is not known whether this potential pathway is important in the development of structural valve deterioration in porcine bioprosthetic aortic valves. The aim of this study was to analyse the association between ABO blood type and clinical manifestations of structural valve deterioration in patients with porcine bioprosthetic aortic heart valves.

Patient and public involvement

There was no patient or public involvement in the design or conduct of this study.

Study design

The design of the study was a nationwide, population-based, observational cohort study. Study reporting followed the Strengthening the Reporting of Observational Studies in Epidemiology and REporting of studies Conducted using Observational Routinely collected health Data guidelines for observational studies using routinely collected data.13 14 The Swedish Web system for Enhancement and Development of Evidence-based care in Heart disease Evaluated According to Recommended Therapies (SWEDEHEART) register15 was used to identify patients who received porcine bioprosthetic aortic valves in Sweden between 1995 and 2012. The register collects pre, peri and postoperative parameters and outcomes of patients receiving cardiac surgery in Sweden.16Patients with concomitant procedures involving any other valves were excluded. ABO blood type was obtained from the Scandinavian Donations and Transfusions Database (SCANDAT2).17 This database contains information including blood type on persons donating or receiving blood in Sweden and Denmark. The study population was categorised into two groups: A (blood type A and AB patients) and non-A (blood type B and O patients). Baseline characteristics were obtained from The National Patient Register18 and the Cause of Death Register,19 maintained by the National Board of Health and Welfare, and the Longitudinal Integration Database for Health Insurance and Labour Market Studies, maintained by Statistics Sweden. Individual-level data linking between the registers were possible because of the Swedish personal identity number.20

Outcomes

The primary outcome was aortic valve reoperation; this information was obtained from the SWEDEHEART register. Secondary outcomes were hospitalisation for heart failure and all-cause mortality, obtained from the National Patient Register and the Cause of Death Register, respectively. The hypothesis was that the anti-A immune response increased the rate of structural valve deterioration in porcine aortic valve bioprostheses. However, because structural valve deterioration is difficult to quantify by variables available from national registers, clinically relevant surrogate measures were selected to represent the presentation of structural valve deterioration. Valve reoperation served as a surrogate measure for prosthesis failure, and heart failure hospitalisation as an indication of progressive valve stenosis or regurgitation.

Missing data

Some baseline patient characteristics were missing: left ventricular ejection fraction (41%) and emergent status of surgery (41%) were missing for all patients operated before 2001. Estimated glomerular filtration rate was missing in 13% of patients. We categorised all patients with missing information regarding the emergent status of surgery as not having emergent status of surgery. Missing data for left ventricular ejection fraction and estimated glomerular filtration rate were handled by multiple imputation by chained equations under the assumption that data were missing at random.21 The imputation models included all variables in table 1, year of surgery, hospital, the event indicator and the Nelson-Aalen estimator of the cumulative baseline hazard.22 Ten datasets were imputed and estimates from these datasets were combined according to Rubin’s rules.
Table 1

Baseline characteristics in 3417 patients with porcine aortic valve bioprostheses according to ABO blood group

VariableBlood groupP valueStandardised difference (%)
A or AB n=1724B or O n=1693
Age, years (mean (SD))76.2 (7.1)76.0 (7.5)0.3283.3
Female791 (45.9)812 (48.0)0.2364.2
Blood group
 A1554 (90.1)
 AB170 (9.9)
 B337 (19.9)
 O1356 (80.1)
Not married549 (38.7)572 (41.4)0.1605.5
Non-Nordic birth region58 (4.1)60 (4.3)0.8251.2
Education0.2766.6
 <10 years632 (52.7)613 (52.5)
 10–12 years408 (34.0)375 (32.1)
 >12 years159 (13.3)180 (15.4)
Household disposable income, kSEK (median (Q1, Q3))182 (126, 265]177 (122, 256]0.1936.3
Body mass index, kg/m2 (mean (SD))26.0 (4.2)26.1 (4.5)0.5412.2
Diabetes263 (15.3)277 (16.4)0.4013.0
Atrial fibrillation294 (17.1)274 (16.2)0.5252.3
Hypertension404 (23.4)384 (22.7)0.6301.8
Hyperlipidaemia153 (8.9)103 (6.1)0.00210.6
Stroke200 (11.6)174 (10.3)0.2364.2
Peripheral vascular disease184 (10.7)145 (8.6)0.0427.2
Chronic pulmonary disease126 (7.3)142 (8.4)0.2674.0
Prior myocardial infarction335 (19.4)271 (16.0)0.0109.0
Prior PCI101 (5.9)80 (4.7)0.1615.1
Prior major bleeding event143 (8.3)162 (9.6)0.2134.5
Prior venous thromboembolism39 (2.3)33 (1.9)0.6052.2
Alcohol dependency21 (1.2)23 (1.4)0.8321.2
Liver disease23 (1.3)18 (1.1)0.5692.5
Cancer190 (11.0)171 (10.1)0.4123.0
eGFR, mL/min/1.73 m2 0.2738.3
 >60894 (59.1)821 (56.5)
 45–60389 (25.7)411 (28.3)
 30–45179 (11.8)161 (11.1)
 15–3036 (2.4)40 (2.8)
 <15 or dialysis14 (0.9)21 (1.4)
Heart failure393 (22.8)420 (24.8)0.1804.7
LV ejection fraction0.3486.5
 >50%731 (70.4)690 (69.7)
 30%–50%259 (24.9)239 (24.1)
 <30%49 (4.7)61 (6.2)
Cardiac implantable electronic device38 (2.2)47 (2.8)0.3353.7
Endocarditis48 (2.8)48 (2.8)1.0000.3
Emergent operation (%)25 (1.5)27 (1.6)0.8371.2

Data are n (%) unless otherwise noted.

kSEK=1000 Swedish krona.

eGFR, estimated glomerular filtration rate; LV, left ventricular; PCI, percutaneous  coronary intervention.

Baseline characteristics in 3417 patients with porcine aortic valve bioprostheses according to ABO blood group Data are n (%) unless otherwise noted. kSEK=1000 Swedish krona. eGFR, estimated glomerular filtration rate; LV, left ventricular; PCI, percutaneous  coronary intervention.

Statistical analysis

Baseline characteristics were described as means and SD, or medians and quartiles for continuous variables. Categorical variables were described as frequencies and percentages. Balance between the groups was assessed by t-tests, X2 tests and standardised mean differences. A standardised mean difference of 10% or less (absolute value) is generally considered an ideal balance.23 Time to event was calculated as time in days from the date of surgery until the date of respective event or end of follow-up (31 December 2013 for aortic valve reoperation or death, and 31 December 2012 for heart failure hospitalisation). We used the Kaplan-Meier method to estimate cumulative survival. Cox proportional hazards regression was used to estimate crude and adjusted HR and 95% CIs for the association between patient blood type and outcomes. The cause-specific hazard for aortic valve reoperation or heart failure was explored by treating competing events (deaths) as censored in the Cox regression analyses. We fitted both univariate models, models including only ABO blood type, age, and sex, as well as fully adjusted models including a range of possible confounding factors. The following variables were included in the fully adjusted Cox regression model: patient age, sex, left ventricular ejection fraction, estimated glomerular filtration rate, atrial fibrillation, hypertension, chronic obstructive pulmonary disease, prior myocardial infarction, prior stroke, hyperlipidaemia, peripheral vascular disease, alcohol dependency, heart failure, diabetes, prior major bleeding event, prior venous thromboembolism and emergent operation. Flexible parametric survival models were used to estimate the cumulative incidence and the cumulative incidence difference of aortic valve reoperation and heart failure, respectively, accounting for the competing risk of death.24 We compared survival probabilities in the study population to that of a Swedish reference general population matched for age, sex and year, available from the Human Mortality Database (http://www. mortality.org).25 We calculated the difference in restricted mean survival time with 95% CI for the aortic valve reoperation outcome at 15 years.26 Data management and statistical analyses were performed using Stata V.15.1 (StataCorp LP) and R version V.3.4.3 (R Foundation for Statistical Computing, Vienna, Austria).

Results

We identified 3417 patients: 1724 (50.5%) in the type A/AB group and 1693 (49.5%) in the type B/O group. There was no significant difference in baseline characteristics except for hyperlipidaemia (8.9% vs 6.1%), peripheral vascular disease (10.7% vs 8.6%) and prior myocardial infarction (19.4% vs 16.0%), all more common in the type A/AB group. The standardised difference was less than 10% for all variables except hyperlipidaemia (standardised difference 10.6%). Baseline characteristics are described in table 1. Incidence rates for aortic valve reoperation, heart failure and death were similar in both groups during follow-up and are reported in table 2.
Table 2

Incidence rate of aortic valve reoperation, heart failure admission or death in 3417 patients with porcine aortic bioprostheses according to blood group

Total (n=3417)Blood group
A or AB (n=1724)B or O (n=1693)
EventsIncidence rate per 100 PY (95% CI)EventsIncidence rate per 100 PY (95% CI)EventsIncidence rate per 100 PY (95% CI)
Aortic valve reoperation
Follow-up time (years)
 0–1351.1 (0.8 to 1.5)221.3 (0.9 to 2.0)130.8 (0.5 to 1.4)
 1–5340.3 (0.2 to 0.4)170.3 (0.2 to 0.5)170.3 (0.2 to 0.5)
 5–15280.3 (0.2 to 0.4)110.2 (0.1 to 0.4)170.4 (0.2 to 0.6)
 Total1000.4 (0.3 to 0.5)520.4 (0.3 to 0.6)480.4 (0.3 to 0.5)
Heart failure
Follow-up time (years)
 0–11695.3 (4.6 to 6.2)915.7 (4.6 to 7.0)784.9 (4.0 to 6.2)
 1–51761.7 (1.5 to 2.0)941.9 (1.5 to 2.3)821.6 (1.3 to 2.0)
 5–152483.4 (3.0 to 3.8)1253.5 (2.9 to 4.1)1233.3 (2.7 to 3.9)
 Total5982.9 (2.7 to 3.1)3123.0 (2.7 to 3.4)2862.7 (2.4 to 3.1)
Death
Follow-up time (years)
 0–11534.6 (3.9 to 5.4)814.8 (3.9 to 6.0)724.4 (3.5 to 5.5)
 1–55855.2 (4.8 to 5.7)3105.6 (5.0 to 6.2)2754.9 (4.3 to 5.5)
 5–15115512 (12 to 13)56012 (11 to 13)59512 (11 to 13)
 Total19177.9 (7.6 to 8.3)9648.1 (7.6 to 8.6)9537.8 (7.4 to 8.3)

PY, person-years.

Incidence rate of aortic valve reoperation, heart failure admission or death in 3417 patients with porcine aortic bioprostheses according to blood group PY, person-years. The crude and adjusted risk of aortic valve reoperation, heart failure hospitalisation or death are shown in table 3. The median follow-up time was 6.8 years and 7.1 years in type A/AB group and type B/O group, respectively. There was no increased risk for aortic valve reoperation in the type B/O group compared with the type A/AB group (HR 0.95, 95% CI 0.62 to 1.45). There was no increased risk for heart failure (HR 0.92, 95% CI 0.77 to 1.08) or all-cause mortality (HR 0.95, 95% CI 0.87 to 1.05) in the type B/O group compared with the type A/AB group.
Table 3

Crude and adjusted risk of aortic valve reoperation, heart failure admission or death in 3417 patients with porcine aortic bioprostheses according to blood group

OutcomeBlood groupCrude HR (95 % CI)Age-adjusted and sex-adjusted HR (95% CI)Multivariable adjusted HR (95 % CI)*
Aortic valve reoperationA or AB (ref)1.001.001.00
B or O1.06 (0.70 to 1.61)1.00 (0.66 to 1.52)0.95 (0.62 to 1.45)
Heart failureA or AB (ref)1.001.001.00
B or O0.91 (0.77 to 1.07)0.92 (0.78 to 1.09)0.92 (0.77 to 1.08)
All-cause deathA or AB (ref)1.001.001.00
B or O0.98 (0.89 to 1.07)0.98 (0.89 to 1.07)0.95 (0.87 to 1.05)

*Adjusted for patient age, sex, left ventricular ejection fraction, estimated glomerular filtration rate, atrial fibrillation, hypertension, chronic obstructive pulmonary disease, prior myocardial infarction, prior stroke, hyperlipidaemia, peripheral vascular disease, alcohol dependency, heart failure, diabetes, prior major bleeding event, prior venous thromboembolism and emergent operation.

Ref, reference category.

Crude and adjusted risk of aortic valve reoperation, heart failure admission or death in 3417 patients with porcine aortic bioprostheses according to blood group *Adjusted for patient age, sex, left ventricular ejection fraction, estimated glomerular filtration rate, atrial fibrillation, hypertension, chronic obstructive pulmonary disease, prior myocardial infarction, prior stroke, hyperlipidaemia, peripheral vascular disease, alcohol dependency, heart failure, diabetes, prior major bleeding event, prior venous thromboembolism and emergent operation. Ref, reference category. The cumulative incidence of aortic valve reoperation was 3.4% (95% CI 2.5% to 4.4%) and 3.6% (95% CI 2.6% to 4.6%) in the type B/O group and the type A/AB group, respectively, at 15 years of follow-up. This corresponded to an absolute risk difference of −0.2% (95% CI −1.5% to 1.2%) (figure 1). Similarly, there was no significant difference in restricted mean survival time for aortic valve reoperation between the type B/O and the type A/AB group at 15 years (6 days, 95% CI: −58 to 70 days, p=0.855). For hospitalisation for heart failure, the cumulative incidence at 15 years was 25% (95% CI, 23% to 28%) in the type A/AB group and 23%, (95% CI 21% to 26%) in the type B/O group, corresponding to an absolute risk difference of −1.8% (95% CI −5.1% to 1.4%). The analyses were repeated in a subset of patients who were operated after 2001 (with less missing data), and we found results that were very similar to the main analyses. We also used a multivariable model that excluded ejection fraction, glomerular filtration rate and emergent status (ie, those variables with most missing data), and we found practically identical results as in our main analysis.
Figure 1

Cumulative incidence of aortic valve reoperation (upper panel) and heart failure hospitalisation (lower panel) in 3417 patients with porcine aortic valve bioprostheses according to ABO blood group.

Cumulative incidence of aortic valve reoperation (upper panel) and heart failure hospitalisation (lower panel) in 3417 patients with porcine aortic valve bioprostheses according to ABO blood group. There was no difference in Kaplan-Meier estimated survival between the groups during 15 years of follow-up (figure 2). The observed overall survival in the total study population was compared with the expected survival of an age and gender-matched Swedish population and is shown in figure 3.
Figure 2

Cumulative survival in 3417 patients with porcine aortic valve bioprostheses according to ABO blood group.

Figure 3

The observed overall survival (95% CI) in the total study population (red line) compared with the expected survival of an age and gender-matched Swedish population (black line).

Cumulative survival in 3417 patients with porcine aortic valve bioprostheses according to ABO blood group. The observed overall survival (95% CI) in the total study population (red line) compared with the expected survival of an age and gender-matched Swedish population (black line).

Discussion

We found no significant difference in the risk of aortic valve reoperation between type A/AB and type B/O patients after porcine bioprosthetic aortic valve replacement during 15 years of follow-up. Furthermore, there was no difference in the risk of heart failure hospitalisation or all-cause mortality. Taken together, these findings suggest that it is safe to use porcine bioprosthetic valves without consideration of ABO blood type in the recipient. Our data also indicate that even if an immune reaction occurs against type A antigens, the clinical manifestation is negligible and does not result in symptomatic structural valve deterioration. The underlying mechanisms for valve deterioration are not fully understood, although mechanical stress and immune reactions are likely culprits. Humoral response against several xenogenic antigens has been shown in patients receiving bioprosthetic heart valves,8 10 27 and a recent case report has identified specific immune responses as the direct cause of increased valve deterioration in specific patients.28 One of the most well-studied antigens in this context is Galα1,3Gal,29 which has a similar structure to the terminal part of certain blood group antigens. It is present on various tissues on most mammals with the exception of Old World apes and humans, and is known to be the antigen responsible for red-meat allergy.30 In a case report, Hawkins et al 28 reported early bioprosthetic failure without signs of endocarditis in two patients with a history of allergic reactions after red meat consumption coupled with increased titres of circulating anti-Galα1,3Gal IgE antibodies.28 Anti-Galα1,3Gal IgM and IgG have also been reported to increase after bioprosthetic aortic valve replacement,9 10 consistent with studies showing Galα1,3Gal epitopes remaining on commercial bioprosthetic valves after pretreatment with, for example, glutaraldehyde.5 These findings support the idea that type A antigens also remain on commercial valves and can initiate immune responses by anti-A antibodies in a manner similar to that occurring in ABO-mismatched organ transplants and blood transfusions. It is likely that bovine species also express blood type antigens, and there are data to support the presence of xenogenic antigens.31 However, the bovine blood type system is more complicated with a high degree of polymorphism especially in the B type.32 This would introduce more unknown factors in this exploratory study, and so the authors choose to focus on porcine species with a limited ABO blood system.

Strengths and limitations

One limitation of the study is that the porcine blood type for each implanted valve was not known. Small experimental studies indicate that type A is slightly more common (ranging from 55% to 94%), and the only other known blood type in the porcine ABO system is type O.11 12 It is possible, but highly unlikely, that all the valves were from type O pigs, which would not yield an ABO mismatch reaction. Another limitation is that we were unable to precisely measure structural valve deterioration, and we had to rely on surrogate endpoints. We lacked the necessary echocardiographic parameters to estimate the incidence of structural valve deterioration according to current standardised definitions,33 and therefore, our study cannot definitively rule out a possible small or subclinical effect of patient blood group on the true rate of structural valve deterioration. However, the clinically important effects of structural valve deterioration are an increased rate of hospitalisation for heart failure (due to increased stenosis or regurgitation), an increased rate of reoperation (due to prosthesis failure) or an increased rate of death associated with the conditions previously mentioned; therefore, the chosen outcome measures would be relevant to patients. In this study, the exposure was patient blood type, and exposure occurred nearly randomly enough to constitute a natural experiment. Another limitation was that we lacked information regarding the cause of death. Baseline characteristics were indeed well balanced between the groups, and residual confounding was likely insignificant. The crude analyses performed here should provide valid estimates of the association between blood type and clinical outcomes, and we found only small changes in the point estimates after multivariable adjustment. Other strengths of the study are a thorough long-term follow-up. Limitations regarding the generalisability of the study findings are the lack of information regarding bioprosthetic valve model and blood group for some patients who underwent surgery during the study period. Only patients who had donated or received blood were included in the SCANDAT2 database, meaning that a different method of obtaining blood type for all patients with known bioprosthetic type would have yielded a larger study population.

Conclusions and clinical interpretation

We found no significant association between patient blood type and clinical manifestations of structural valve deterioration following porcine aortic valve replacement. The absolute risk difference between patients with type A/AB and type B/O blood groups at 15 years was negligible. Our findings suggest that it is safe to use porcine bioprosthetic valves without consideration of ABO blood type in the recipient.
  31 in total

1.  Strengthening the Reporting of Observational Studies in Epidemiology (STROBE) statement: guidelines for reporting observational studies.

Authors:  Erik von Elm; Douglas G Altman; Matthias Egger; Stuart J Pocock; Peter C Gøtzsche; Jan P Vandenbroucke
Journal:  BMJ       Date:  2007-10-20

2.  2017 ESC/EACTS Guidelines for the management of valvular heart disease.

Authors:  Helmut Baumgartner; Volkmar Falk; Jeroen J Bax; Michele De Bonis; Christian Hamm; Per Johan Holm; Bernard Iung; Patrizio Lancellotti; Emmanuel Lansac; Daniel Rodriguez Muñoz; Raphael Rosenhek; Johan Sjögren; Pilar Tornos Mas; Alec Vahanian; Thomas Walther; Olaf Wendler; Stephan Windecker; Jose Luis Zamorano
Journal:  Eur Heart J       Date:  2017-09-21       Impact factor: 29.983

3.  Validity of the Swedish Cardiac Surgery Registry.

Authors:  Per Vikholm; Torbjörn Ivert; Johan Nilsson; Anders Holmgren; Wolfgang Freter; Lisa Ternström; Haider Ghaidan; Ulrik Sartipy; Christian Olsson; Hans Granfeldt; Sigurdur Ragnarsson; Örjan Friberg
Journal:  Interact Cardiovasc Thorac Surg       Date:  2018-07-01

4.  Anti-alpha-Gal antibody response following xenogeneic heart valve implantation in adults.

Authors:  Chun Soo Park; Sam-Se Oh; Young Eun Kim; Sun Young Choi; Hong-Gook Lim; Hyuk Ahn; Yong Jin Kim
Journal:  J Heart Valve Dis       Date:  2013-03

5.  Immune response in patients receiving a bioprosthetic heart valve: lack of response with decellularized valves.

Authors:  Oliver Bloch; Pia Golde; Pascal M Dohmen; Steffen Posner; Wolfgang Konertz; Wilhelm Erdbrügger
Journal:  Tissue Eng Part A       Date:  2011-06-20       Impact factor: 3.845

6.  Multiple imputation using chained equations: Issues and guidance for practice.

Authors:  Ian R White; Patrick Royston; Angela M Wood
Journal:  Stat Med       Date:  2010-11-30       Impact factor: 2.373

7.  Alpha-Gal specific IgG immune response after implantation of bioprostheses.

Authors:  A Mangold; T Szerafin; K Hoetzenecker; S Hacker; M Lichtenauer; T Niederpold; S Nickl; M Dworschak; R Blumer; J Auer; H J Ankersmit
Journal:  Thorac Cardiovasc Surg       Date:  2009-05-20       Impact factor: 1.827

8.  The Swedish Web-system for enhancement and development of evidence-based care in heart disease evaluated according to recommended therapies (SWEDEHEART).

Authors:  Tomas Jernberg; Mona F Attebring; Kristina Hambraeus; Torbjorn Ivert; Stefan James; Anders Jeppsson; Bo Lagerqvist; Bertil Lindahl; Ulf Stenestrand; Lars Wallentin
Journal:  Heart       Date:  2010-08-27       Impact factor: 5.994

9.  The REporting of studies Conducted using Observational Routinely-collected health Data (RECORD) statement.

Authors:  Eric I Benchimol; Liam Smeeth; Astrid Guttmann; Katie Harron; David Moher; Irene Petersen; Henrik T Sørensen; Erik von Elm; Sinéad M Langan
Journal:  PLoS Med       Date:  2015-10-06       Impact factor: 11.069

10.  The Swedish cause of death register.

Authors:  Hannah Louise Brooke; Mats Talbäck; Jesper Hörnblad; Lars Age Johansson; Jonas Filip Ludvigsson; Henrik Druid; Maria Feychting; Rickard Ljung
Journal:  Eur J Epidemiol       Date:  2017-10-05       Impact factor: 8.082

View more
  1 in total

1.  Comparison of Long-term Performance of Bioprosthetic Aortic Valves in Sweden From 2003 to 2018.

Authors:  Michael Persson; Natalie Glaser; Johan Nilsson; Örjan Friberg; Anders Franco-Cereceda; Ulrik Sartipy
Journal:  JAMA Netw Open       Date:  2022-03-01
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.