| Literature DB >> 31060563 |
Ying Wang1, Zhengyi Sun1, Aipeng Li2, Yongsheng Zhang3.
Abstract
BACKGROUND: Inconsistent results according to numerous studies that had investigated the association between serum zinc levels and lung cancer risk were reported. The aim of this study was to explore whether serum zinc levels were lower in lung cancer patients than that in controls.Entities:
Keywords: Lung cancer; Meta-analysis; Serum zinc or serum zinc level
Mesh:
Substances:
Year: 2019 PMID: 31060563 PMCID: PMC6503426 DOI: 10.1186/s12957-019-1617-5
Source DB: PubMed Journal: World J Surg Oncol ISSN: 1477-7819 Impact factor: 2.754
Fig. 1Flow diagram of the literature search
Characteristics of studies between serum zinc levels and lung cancer risk
| Study, year | Country | Study type | Age | Lung cancer cases | Controls | Methods of measured zinc | ||
|---|---|---|---|---|---|---|---|---|
|
| Zinc: mean ± SD |
| Zinc: mean ± SD | |||||
| Sun et al., 1991 | China | Case-control | 30–75 | 104 | M = 0.945 ± 0.303(μg/mL) | 252 | M = 0.945 ± 0.23(μg/mL) | Atomic absorption spectrophotometer measurements (IL-951, USA) |
| Cobanoglu et al., 2010 | Turkey | Case-control | 54 ± 8.29 | 30 | 0.539 ± 0.225 (μg/dL) | 20 | 2.051 ± 0.298 (μg/dL) | UNICAM-929 spectrophotometer (Unicam Ltd, York Street, Cambridge, UK) |
| Diez et al., 1989 | Spain | Case-control | 60 ± 7 | 64 | 0.627 ± 0.136 (μg/mL) | 100 | 0.733 ± 0.173 (μg/mL) | Perkin-Elmer 5.000 atomic absorption spectrophotometer |
| Jin et al., 2011 | China | Case-control | 34.9 ± 21.3 | 154 | 0.673 ± 0.47 (μg/mL) | 154 | 1.27 ± 0.442 (μg/mL) | Atomic absorption spectrophotometer (Wako Pure Chemical Industries, Osaka, Japan) |
| Oyama et al., 1994 | Japan | Case-control | 26–83 | 109 | 0.853 ± 0.279 (μg/mL) | 53 | 0.873 ± 0.324 (μg/mL) | Atomic absorption spectrophotometry (Wako Pure Chemical Industries, Osaka, Japan) |
| Zablocka-Slowinska et al., 2018 | Poland | Case-control | 50–70 | 44 | 0.86 ± 0.215 (μg/L) | 44 | 0.99 ± 0.263 (μg/L) | Atomic absorption spectrometry |
| Zowczak et al., 2001 | Poland | Case-control | 42–87 | 14 | 12 ± 2 (μmol/L) | 18 | 13.8 ± 2 (μmol/L) | Flame atomic absorption spectrometry using Perkin ELmer spectrometer |
| Feng et al., 2006 | China | Observation study | 18–82 | 13 | 17.72 ± 2.55 (μmol/L) | 36 | 17.57 ± 2.74 (μmol/L) | Flame atomic absorption spectrometry |
| Zhang et al., 1997 | China | Case-control | 25–80 | 64 | 0.788 ± 0.171 (μg/mL) | 31 | 0.91 ± 0.374 (μg/mL) | Atomic absorption spectrophotometer measurements |
| Jin et al., 2001 | China | Case-control | 45–70 | 40 | 11.1 ± 3.73 (μmol/L) | 46 | 13.4 ± 2.5 (μmol/L) | Atomic absorption spectrophotometer measurements |
| Zhang et al., 1994 | China | Case-control | 59 ± 9 | 40 | 16.98 ± 3.06 (μmol/L) | 24 | 20.96 ± 3.67 (μmol/L) | Atomic absorption spectrophotometer measurements |
| Xu et al., 1993 | China | Case-control | 56 ± 7.5 | 42 | 11.45 ± 2.08 (μmol/L) | 40 | 13.78 ± 2.12 (μmol/L) | Atomic absorption spectrophotometer measurements |
| Zhou et al., 1995 | China | Case-control | 39–69 | 186 | 0.702 ± 0.182 (μg/mL) | 150 | 0.976 ± 0.102 (μg/mL) | Atomic absorption spectrophotometer measurements |
| Chen et al., 1994 | China | Case-control | 37–72 | 58 | 27.4 ± 4.8 (mol/L) | 100 | 14.5 ± 3.8 (mol/L) | Atomic absorption spectrophotometer measurements (MFX-ID) |
| Luo et al., 1996 | China | Case-control | 40–70 | 35 | 10.25 ± 1.38 (μmol/L) | 22 | 12.85 ± 4.28 (μmol/L) | Atomic Absorption Spectrophotometer measurements |
| Mo et al., 1995 | China | Case-control | 58.5 | 57 | 0.719 ± 0.159 (μg/mL) | 46 | 0.955 ± 0.139 (μg/mL) | Atomic absorption spectrophotometer measurements |
| He et al., 1995 | China | Case-control | 34–72 | 143 | 19.481 ± 3.671(μmol/L) | 50 | 21.436 ± 6.278(μmol/L) | Atomic absorption spectrophotometer measurements |
| Wei L et al., 2002 | China | Case-control | 22–76 | 79 | 0.832 ± 0.092 (μg/mL) | 32 | 1.182 ± 0.018 (μg/mL) | Atomic absorption spectrophotometer measurements (American p-100) |
| Zhao et al., 1993 | China | Case-control | 43–62 | 46 | 11.17 ± 3.74 (μmol/L) | 50 | 16.92 ± 5.6 (μmol/L) | Atomic absorption spectrophotometer measurements (BJKP-36) |
| He et al., 2011 | China | Case-control | 38–69 | 104 | 9.08 ± 1.44 (μmol/L) | 122 | 16.44 ± 1.69 (μmol/L) | Atomic absorption spectrophotometer measurements |
| Chen et al., 1998 | China | Case-control | 47–72 | 43 | 11.74 ± 2.74 (μmol/L) | 180 | 13 ± 1.83 (μmol/L) | Atomic absorption spectrophotometer measurements (Japan Shimadzu-A670) |
| Liang et al., 1992 | China | Case-control | 61 | 57 | 13.86 ± 5.56 (μmol/L) | 80 | 21.81 ± 3.38 (μmol/L) | Atomic absorption spectrophotometer measurements (Chinese WFX-ID) |
| Huang et al., 1998 | China | Case-control | 25–65 | 136 | 11.933 ± 2.68 (μmol/L) | 7101 | 19.808 ± 6.43(μmol/L) | Atomic absorption spectrophotometer measurements (Japan Shimadzu-AA670/C2H2) |
| Wang et al., 2003 | China | Case-control | 28–69 | 50 | 0.74 ± 0.18 (μg/L) | 60 | 1.83 ± 1.44 (μg/L) | Atomic absorption spectrophotometer measurements |
| Cheng et al., 2011 | China | Case-control | 37–68 | 197 | 0.9 ± 0.3 (μmol/L) | 93 | 1.12 ± 0.56 (μmol/L) | Atomic absorption spectrophotometer measurements |
| Xie et al., 2000 | China | Case-control | 35–68 | 64 | 70.28 ± 10.6 (μmol/L) | 100 | 80.3 ± 20.7 (μmol/L) | Atomic absorption spectrophotometer measurements |
| Du et al., 1996 | China | Case-control | 22–73 | 73 | 13.1 ± 4 (μmol/L) | 63 | 15.2 ± 3.5 (μmol/L) | Atomic absorption spectrophotometer measurements |
| Zhu et al., 1997 | China | Case-control | NA | 56 | 13.16 ± 1.71 (μmol/L) | 118 | 15.46 ± 2.13 (μmol/L) | Atomic absorption spectrophotometer measurements (Perkin Elmer Zeeman/3030, USA) |
| Zhang et al., 2000 | China | Case-control | 25–77 | 310 | 0.812 ± 0.16 (μg/mL) | 48 | 1.039 ± 0.154 (μg/mL) | Atomic absorption spectrophotometer measurements (Japan Shimadzu-180-80) |
| Hu et al., 2000 | China | Case-control | 36–77 | 56 | 0.797 ± 0.176 (μg/mL) | 60 | 0.908 ± 0.022 (μg/mL) | Atomic Absorption Spectrophotometer measurements |
| Guo et al., 1994 | China | Case-control | 55.1 | 26 | 1.28 ± 0.94 (μg/mL) | 26 | 0.8 ± 0.25 (μg/mL) | Atomic absorption spectrophotometer measurements (Varian Spectr AA-40p, USA) |
| Han et al., 1999 | China | Case-control | 4–77 | 400 | 0.93 ± 0.38 (μg/mL) | 100 | 1.1 ± 0.36 (μg/mL) | Atomic absorption spectrophotometer measurements (American PE3030) |
SD standard deviation, NA not available, F female, M male
Fig. 2Forest plot of standard mean difference (SMD) with corresponding 95% confidence interval (CI) of studies about serum zinc levels and lung cancer risk