Literature DB >> 31055190

A liquid chromatography-tandem mass spectrometry method for simultaneous determination of simeprevir, daclatasvir, sofosbuvir, and GS-331007 applied to a retrospective clinical pharmacological study.

Davide Ferrari1, Sabrina Bagaglio2, Michele Raso3, Laura Galli2, Simone Premaschi3, Emanuela Messina2, Giulia Morsica2, Massimo Locatelli3, Caterina Uberti-Foppa4, Hamid Hasson2.   

Abstract

A highly sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and validated for simultaneous determination of daclatasvir (DCV), simeprevir (SMV), sofosbuvir (SOF), and its major metabolite GS-331007 in human plasma using stable-isotope-labeled (SIL) analogs as internal standards (IS) to minimize a possible matrix effect. Liquid-liquid extraction (LLE) of the analytes and IS from human plasma was performed using a commercial extraction kit requiring low sample volume (50 μL). The analytes were eluted under a gradient program with mobile phase A (water + 0.1% formic acid) and mobile phase B (methanol + 0.1% formic acid) at a flow-rate of 0.6 mL/min for 10 min. The detection was performed on a Qtrap 5500 triple quadrupole tandem-mass spectrometer using multiple reaction monitoring (MRM) mode via the positive electrospray ionization interface. The method was validated according to the European Medicine Agency (EMA) guidelines over the clinically relevant concentration range of 15.6-2000 ng/mL. The high reproducibility, the low matrix effect associated with the use of SIL-IS, and the need of small sample amounts make this method particularly suited for high-throughput routine analysis. The proposed method was successfully applied to a retrospective clinical pharmacology study involving 67 HIV/HCV co-infected patients treated with a SOF-based therapy. DCV, SMV, SOF, and GS-331007 plasma levels were measured at week 4 of treatment and compared with the patients' clinical and laboratory characteristics. Higher GS-331007 plasma concentrations were observed in female patients compared to males, which can be explained by different anthropometric characteristics between genders. Importantly, patients with high plasma levels of GS-331007 also showed enhanced concentration of DCV and SMV probably due to a specific metabolic/pathological condition. Altogether, our findings indicate that the proposed method is a reliable and accurate new tool for high-throughput screening of large patient cohorts that could be readily used to optimize treatment modalities and reduce drug-related toxicities.
Copyright © 2019 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  DAA; Daclatasvir; HCV; Simeprevir; Sofosbuvir; Tandem-mass spectrometry

Mesh:

Substances:

Year:  2019        PMID: 31055190     DOI: 10.1016/j.jchromb.2019.04.048

Source DB:  PubMed          Journal:  J Chromatogr B Analyt Technol Biomed Life Sci        ISSN: 1570-0232            Impact factor:   3.205


  1 in total

1.  Evaluation of antibody titer kinetics and SARS-CoV-2 infections in a large cohort of healthcare professionals ten months after administration of the BNT162b2 vaccine.

Authors:  Davide Ferrari; Alessandro Ambrosi; Chiara Di Resta; Rossella Tomaiuolo; Massimo Locatelli; Giuseppe Banfi
Journal:  J Immunol Methods       Date:  2022-06-02       Impact factor: 2.287

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.