Literature DB >> 31053351

Development and validation of a semi-quantitative ultra-high performance liquid chromatography-tandem mass spectrometry method for screening of selective androgen receptor modulators in urine.

Emiliano Ventura1, Anna Gadaj2, Gail Monteith3, Alexis Ripoche3, Jim Healy4, Francesco Botrè5, Saskia S Sterk6, Tom Buckley7, Mark H Mooney3.   

Abstract

A semi-quantitative method was developed to monitor the misuse of 15 SARM compounds belonging to nine different families, in urine matrices from a range of species (equine, canine, human, bovine and murine). SARM residues were extracted from urine (200 μL) with tert-butyl methyl ether (TBME) without further clean-up and analysed by ultra-high performance liquid chromatography coupled to tandem mass spectrometry (UHPLC-MS/MS). A 12 min gradient separation was carried out on a Luna Omega Polar C18 column, employing water and methanol, both containing 0.1% acetic acid (v/v), as mobile phases. The mass spectrometer was operated both in positive and negative electrospray ionisation modes (ESI±), with acquisition in selected reaction monitoring (SRM) mode. Validation was performed according to the EU Commission Decision 2002/657/EC criteria and European Union Reference Laboratories for Residues (EU-RLs) guidelines with CCβ values determined at 1 ng mL-1, excluding andarine (2 ng mL-1) and BMS-564929 (5 ng mL-1), in all species. This rapid, simple and cost effective assay was employed for screening of bovine, equine, canine and human urine to determine the potential level of SARMs abuse in stock farming, competition animals as well as amateur and elite athletes, ensuring consumer safety and fair play in animal and human performance sports.
Copyright © 2019 The Authors. Published by Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Doping control; Residue and food safety; Selective androgen receptor modulators; UHPLC-MS/MS; Urine

Mesh:

Substances:

Year:  2019        PMID: 31053351     DOI: 10.1016/j.chroma.2019.04.050

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  3 in total

1.  Hand-Held Diode Laser for On-Site Analysis Using Transportable Mass Spectrometry.

Authors:  Ane Arrizabalaga-Larrañaga; Michel W F Nielen; Marco H Blokland
Journal:  Anal Chem       Date:  2021-06-02       Impact factor: 6.986

2.  Enhanced UHPLC-MS/MS screening of selective androgen receptor modulators following urine hydrolysis.

Authors:  Anna Gadaj; Emiliano Ventura; Jim Healy; Francesco Botrè; Saskia S Sterk; Tom Buckley; Mark H Mooney
Journal:  MethodsX       Date:  2020-05-21

3.  Monitoring of selective androgen receptor modulators in bovine muscle tissue by ultra-high performance liquid chromatography-tandem mass spectrometry.

Authors:  Anna Gadaj; Emiliano Ventura; Alexis Ripoche; Mark H Mooney
Journal:  Food Chem X       Date:  2019-09-24
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.