Use of fast Fourier transforms in calculating dose distributions for irregularly shaped fields for three-dimensional treatment planning.

R Mohan, C S Chui.   

Abstract

In three-dimensional radiation treatment planning, essentially all fields are irregular and compensated. Consequently, it is important to predict accurately dose for such fields to ensure adequate coverage of the target region and sparing of healthy tissues. Traditional approaches, namely, those involving scatter integration and extended source and those utilizing negatively weighted fields, are inaccurate, especially near the boundaries defined by blocks and collimators. In the method presented in this paper, dose distributions for arbitrarily shaped beams are calculated by two-dimensional convolution of the relative primary photon fluence distributions and kernels representing the cross-sectional profiles of a pencil beam at a series of depths. The pencil beam dose distributions are computed, once and for all, with the Monte Carlo method for photon energy spectrum for each treatment machine. The finite size of the source, which is important for cobalt machines, is also taken into account using convolution of the source with the relative primary fluence distribution. Convolutions are performed using fast Fourier transforms on an array processor. Results of calculations are in excellent agreement with measured data. While no data are presented for fields modified by compensators, the method of calculation should apply at least as well for such fields since the variations in fluence distribution for compensated fields are not as sharp as for points near the block boundaries.

Entities:  

Mesh:

Year:  1987        PMID: 3104741     DOI: 10.1118/1.596097

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  5 in total

1.  Monte Carlo simulations applied to conjunctival lymphoma radiotherapy treatment.

Authors:  Lorenzo Brualla; Ricardo Palanco-Zamora; Klaus-Peter Steuhl; Norbert Bornfeld; Wolfgang Sauerwein
Journal:  Strahlenther Onkol       Date:  2011-07-25       Impact factor: 3.621

Review 2.  Advances in radiation technology can improve survival and quality of life for cancer patients.

Authors:  J Armstrong
Journal:  Ir J Med Sci       Date:  2001 Jan-Mar       Impact factor: 2.089

3.  Limited accuracy of dose calculation for large fields at deep depths using the BrainSCAN v5.21 treatment planning system.

Authors:  Wen C Hsi; Yunkai Zhang; Michael C Kirk; Damian Bernard; James C H Chu
Journal:  J Appl Clin Med Phys       Date:  2005-05-19       Impact factor: 2.102

4.  A multinational audit of small field output factors calculated by treatment planning systems used in radiotherapy.

Authors:  Wolfgang Lechner; Paulina Wesolowska; Godfrey Azangwe; Mehenna Arib; Victor Gabriel Leandro Alves; Luo Suming; Daniela Ekendahl; Wojciech Bulski; José Luis Alonso Samper; Sumanth Panyam Vinatha; Srimanoroth Siri; Milan Tomsej; Mikko Tenhunen; Julie Povall; Stephen F Kry; David S Followill; David I Thwaites; Dietmar Georg; Joanna Izewska
Journal:  Phys Imaging Radiat Oncol       Date:  2018-03-06

5.  Using the frame averaging of aS500 EPID for IMRT verification.

Authors:  J Chang; C C Ling
Journal:  J Appl Clin Med Phys       Date:  2003       Impact factor: 2.102

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.