| Literature DB >> 31046726 |
Salem Abdulraheem1,2, Liselotte Paulsson3, Sofia Petrén3, Mikael Sonesson3.
Abstract
OBJECTIVE: To examine: (I) the current evidence of the impact of fixed orthodontic appliances on the development of halitosis in patients undergoing orthodontic treatment, and (II) the influence of different orthodontic bracket systems on halitosis.Entities:
Keywords: Fixed orthodontic appliance; Halitosis; Systematic review
Mesh:
Year: 2019 PMID: 31046726 PMCID: PMC6498650 DOI: 10.1186/s12903-019-0761-1
Source DB: PubMed Journal: BMC Oral Health ISSN: 1472-6831 Impact factor: 2.757
Search strategy searching PubMed
| Search block | |
|---|---|
| #1 | Bad breath OR oral odor OR oral malodor OR oral malodour OR oral odour OR Halitosis OR “Halitosis” [Mesh] AND Orthodontic Appliances [Mesh] OR Orthodontic Appliances OR “Orthodontic Brackets”[Mesh] OR Orthodontic appliances OR “Orthodontic Brackets” OR Orthodontic Brackets OR Orthodontic Braces OR fixed orthodontic appliances OR fixed orthodontic appliance |
| #2 | Adolescents AND Halitosis |
Fig. 1Flowchart of study selection performed according to the PRISMA guidelines
Summarised data of the three studies included in the review
| Study information | Study design | Sample (n) | Interventions | Halitosis examinations | Additional examinations | Outcomes |
|---|---|---|---|---|---|---|
| Kaygisiz | - RCT | - 60 | Group I: SLB in both arches | - Halimeter | Plaque Index | No statistically significant difference between pre-bonding and post-bonding VSC values |
| Nalcaci | - RCT | - 46 | Group I: SLB Unknown number of arches | - Halimeter | Plaque index | Statistically significant increase of VSC mean values between pre-bonding and post-bonding measured after 1 and 5 weeks of bonding. |
| Babacan | - RCT | - 44 | Group I: CB in both arches | - Halimeter | Plaque index | Statistically significant increase of VSC mean values between pre-bonding and post-bonding measured after 1 and 4 weeks of bonding. |
Fig. 2The four assessors’ judgements using the Cochrane risk of bias assessment tool [21]. The domains were assessed as low, high or unclear risk of bias (marked as green, yellow and red). All studies were assigned as an overall risk of bias