Literature DB >> 31046630

Validity of Activity Trackers in Estimating Energy Expenditure During High-Intensity Functional Training.

Cody E Morris1, Paige A Wessel2, Rachel A Tinius2, Mark A Schafer2, Jill M Maples3.   

Abstract

Purpose: The purpose of this study was to evaluate the agreement of five commercially available accelerometers in estimating energy expenditure while performing an acute bout of high-intensity functional training (HIFT).
Methods: Participants (n = 47; average age: 28.5 ± 11.6 years) consisted of recreationally active, healthy adults. Each participant completed a session of HIFT: a 15-minute workout consisting of 12 repetitions each of air-squats, sit-ups, push-ups, lunges, pull-ups, steps-ups, and high-knees; performed circuit-style by completing as many rounds as possible. During this session, each participant wore the Cosmed K4b2 portable metabolic analyzer (PMA) and five different accelerometers (ActiGraph GT3X, Nike Fuelband, Fitbit One, Fitbit Charge HR, and Jawbone UP Move).
Results: Four of the five activity trackers reported lower (p < .05) total EE values compared to the PMA during the acute bout of HIFT. The waist-mounted device (ActiGraph, 182.55 ± 37.93 kcal) was not significantly different from, and most closely estimated caloric expenditure compared to the PMA (144.99 ± 37.13 kcal) (p = .056). A repeated-measures ANOVA showed that all activity trackers were significantly different from the reference measure (PMA) (p < .05). Systematic relative agreement between the activity trackers was calculated, exhibiting a significant ICC = 0.426 (F [46,230] = 5.446 [p < .05]).
Conclusion: The wrist- and hip-mounted activity trackers did not accurately assess energy expenditure during HIFT exercise. With the exception of the ActiGraph GT3X, the remaining four activity trackers showed inaccurate estimates of the amount of kilocalories expended during the HIFT exercise bout compared to the PMA.

Entities:  

Keywords:  Body weight resistance training; activity trackers; estimating energy expenditure; physical activity

Mesh:

Year:  2019        PMID: 31046630     DOI: 10.1080/02701367.2019.1603989

Source DB:  PubMed          Journal:  Res Q Exerc Sport        ISSN: 0270-1367            Impact factor:   2.500


  3 in total

Review 1.  Accuracy and Precision of Energy Expenditure, Heart Rate, and Steps Measured by Combined-Sensing Fitbits Against Reference Measures: Systematic Review and Meta-analysis.

Authors:  Guillaume Chevance; Natalie M Golaszewski; Elizabeth Tipton; Eric B Hekler; Matthew Buman; Gregory J Welk; Kevin Patrick; Job G Godino
Journal:  JMIR Mhealth Uhealth       Date:  2022-04-13       Impact factor: 4.947

2.  Energy Expenditure Estimation of Tabata by Combining Acceleration and Heart Rate.

Authors:  Yiping Yan; Qingguo Chen
Journal:  Front Public Health       Date:  2022-02-07

3.  Reliability and Validity of Commercially Available Wearable Devices for Measuring Steps, Energy Expenditure, and Heart Rate: Systematic Review.

Authors:  Daniel Fuller; Emily Colwell; Jonathan Low; Kassia Orychock; Melissa Ann Tobin; Bo Simango; Richard Buote; Desiree Van Heerden; Hui Luan; Kimberley Cullen; Logan Slade; Nathan G A Taylor
Journal:  JMIR Mhealth Uhealth       Date:  2020-09-08       Impact factor: 4.773

  3 in total