Literature DB >> 31042439

Arthroscopic Repair of the Isolated Subscapularis Full-Thickness Tear: Single- Versus Double-Row Suture-Bridge Technique.

Ji-Sang Yoon1, Sung-Jae Kim1, Yun-Rak Choi1, Sang-Ho Kim1, Yong-Min Chun1.   

Abstract

BACKGROUND: No clinical comparative study has addressed isolated subscapularis tears after arthroscopic repair with either single-row or double-row suture-bridge technique. PURPOSE/HYPOTHESIS: The purpose of this study is to compare clinical outcomes and structural integrity after arthroscopic repair of an isolated subscapularis full-thickness tear with either the single-row technique or the double-row suture-bridge technique. The authors hypothesized that there would be no significant differences in clinical outcomes and structural integrity between approaches. STUDY
DESIGN: Cohort study; Level of evidence, 3.
METHODS: This study included 56 patients who underwent arthroscopic repair of an isolated subscapularis full-thickness tear with grade II or less fatty infiltration in the subscapularis muscle with either a single-row technique (n = 31) or a double-row suture-bridge technique (n = 25). Functional outcomes were assessed with the visual analog scale (VAS) for pain, Subjective Shoulder Value (SSV), American Shoulder and Elbow Surgeons (ASES) score, the University of California, Los Angeles (UCLA) shoulder score, and active range of motion. Magnetic resonance arthrography (MRA) or computed tomographic arthrography (CTA) was performed 6 months after surgery to assess the structural integrity of the repaired tendon.
RESULTS: At the 2-year follow-up, all scoring parameters applied (VAS, SSV, ASES, and UCLA), subscapularis strength, and active range of motion improved significantly in both groups as compared with preoperative values ( P < .001). However, there were no significant differences between groups in any of these clinical outcome measurements (VAS, 1.2 vs 1.1; SSV, 91.3 vs 91.8; ASES, 91.0 vs 91.4; UCLA, 31.9 vs 32.1). On follow-up MRA or CTA, the overall retear rate did not differ significantly between the single-row group (13%, 4 of 31) and the double-row group (12%, 3 of 25).
CONCLUSION: Arthroscopic single-row repair and double-row suture-bridge repair of isolated full-thickness subscapularis tears both yielded satisfactory clinical outcomes and structural integrity with no significant differences among patients with good muscle quality.

Entities:  

Keywords:  magnetic resonance imaging; rotator cuff; shoulder

Mesh:

Year:  2019        PMID: 31042439     DOI: 10.1177/0363546519838281

Source DB:  PubMed          Journal:  Am J Sports Med        ISSN: 0363-5465            Impact factor:   6.202


  14 in total

Review 1.  Literature Review of Subscapularis Tear, Associated injuries, and the Available Treatment Options.

Authors:  Daniel B Goldberg; Trent M Tamate; Morgan Hasegawa; Thomas J K Kane; Jae S You; Scott N Crawford
Journal:  Hawaii J Health Soc Welf       Date:  2022-03

2.  Quantitative MRI indicators and features for partial subscapularis tendon tears on conventional shoulder MRI.

Authors:  Qiqi Wang; Jie Zhao; Suying Zhou; Yuchan Lv; Xin Liu; Haitao Yang
Journal:  Insights Imaging       Date:  2022-10-20

Review 3.  Current concepts review in the management of subscapularis tears.

Authors:  Girinivasan Chellamuthu; Shyam Sundar; David V Rajan
Journal:  J Clin Orthop Trauma       Date:  2022-04-12

4.  What Factors Are Associated with Symptomatic Rotator Cuff Tears: A Meta-analysis.

Authors:  Jinlong Zhao; Minghui Luo; Guihong Liang; Jianke Pan; Yanhong Han; Lingfeng Zeng; Weiyi Yang; Jun Liu
Journal:  Clin Orthop Relat Res       Date:  2022-01-01       Impact factor: 4.755

5.  Modified Double-Row Suture Bridge Technique With Double-Row Biceps Tenodesis for Massive Rotator Cuff Tear.

Authors:  Joseph Maalouly; Dany Aouad; Antonios Tawk; Georges El Rassi
Journal:  Arthrosc Tech       Date:  2020-05-23

6.  Comparative efficacy of 5 suture configurations for arthroscopic rotator cuff tear repair: a network meta-analysis.

Authors:  Wei Wang; Hui Kang; Hongchuan Li; Jian Li; Yibin Meng; Peng Li
Journal:  J Orthop Surg Res       Date:  2021-12-11       Impact factor: 2.359

Review 7.  Risk factors for full-thickness rotator cuff tears: a systematic review and meta-analysis.

Authors:  Jinlong Zhao; Jianke Pan; Ling-Feng Zeng; Ming Wu; Weiyi Yang; Jun Liu
Journal:  EFORT Open Rev       Date:  2021-11-19

Review 8.  A comparison of simple and complex single-row versus transosseous-equivalent double-row repair techniques for full-thickness rotator cuff tears: a systematic review and meta-analysis.

Authors:  Nikhil Ponugoti; Aashish Raghu; Henry B Colaco; Henry Magill
Journal:  JSES Int       Date:  2021-10-26

9.  Comparison of Knotless and Knotted Single-Anchor Repair for Ruptures of the Upper Subscapularis Tendon: Outcomes at 2-Year Follow-up.

Authors:  Mirco Sgroi; Marilena Kranz; Andreas Martin Seitz; Marius Ludwig; Martin Faschingbauer; Timo Zippelius; Heiko Reichel; Thomas Kappe
Journal:  Orthop J Sports Med       Date:  2022-03-15

10.  Clinical Outcomes for Isolated Subscapularis Tears With Advanced Fatty Infiltration: Nonoperative Treatment Versus Arthroscopic Single-Row Repair.

Authors:  Tae-Hwan Yoon; Sung-Jae Kim; Yun-Rak Choi; Ho-Sung Keum; Yong-Min Chun
Journal:  Orthop J Sports Med       Date:  2021-02-02
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.